• 제목/요약/키워드: Volatile chemicals

검색결과 158건 처리시간 0.027초

셀룰로오스 종이 상에 Oxime 도입된 polypyrrole 층을 제조한 신경작용제 선택적 화학저항 센서 (Nerve-Agent Selective Chemiresistors Fabricated by Oxime Decorated Polypyrrole Layer on Cellulose Paper)

  • 전창훈;하태환
    • 한국군사과학기술학회지
    • /
    • 제27권4호
    • /
    • pp.528-534
    • /
    • 2024
  • In continuous research of detecting highly toxic chemical warfare agents to ensure preparedness for the future battlefield, flexible and wearable sensor platforms with high sensitivity are still demanding. Herein we demonstrate a facile fabrication of polypyrrole-based chemiresistors on cellulose paper for the detection of nerve gas simulants. In order to optimize electrical properties of sensor platform, conducting polymer made of polypyrrole were first synthesized on flexible cellulose paper and interdigitated electrodes were formed thereon. Following confirmation of polypyrrole and/or oxime moiety through FT-IR analyses, electrical characteristics were measured in the various ratio of monomers between simple pyrrole and oxime-modified one. Typically for the optimized chemiresistor(2:8 molar ratio of simple pyrrole and oxime-modified one), eleven species of chemical warfare agents were examined and enhanced conductivity(104~105 order) was observed for three simulants(diethyl cyanophosphonate, diisopropyl fluorophosphonate and diethyl chlorophosphonate), which was mainly attributed to intermolecular hydrogen bonding, while no significant responses was recorded against sixteen common volatile organic chemicals.

지하수중 음이온, 양이온, 및 금속의 함량 (Groundwater Contamination by Cation, Anion and Pesticides)

  • 김형석;정세영;최중명
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

태우는 생활화학제품(향초와 인센스 스틱)의 사용이 실내 공기질에 미치는 영향 (Effects on Indoor Air Quality of Burning Chemicals (Scented Candles and Incense Sticks))

  • 박은아;어승연;오예린;박나연;이명호;고영림
    • 한국환경보건학회지
    • /
    • 제50권1호
    • /
    • pp.36-42
    • /
    • 2024
  • Background: The use of scented candles and incense sticks, both of which are household products that are burned for indoor deodorization and calming effects, is increasing. Fine dust has been designated as a group 1 carcinogen by the International Agency for Research on Cancer. Volatile organic compounds (VOCs) affect air pollution and can cause diseases. Objectives: This study aims to determine the effect on indoor air quality by measuring PM2.5 and VOCs generated when burning scented candles and incense sticks. Methods: Scented candles and incense sticks were selected as household products to burn. As for the target sample, top-selling products (five types of scented candles, five types of incense sticks) were purchased online. The PM2.5 concentration according to time was measured immediately next to the sample and three meters away from each other in an enclosed space using a real-time aerosol photometer. VOCs were collected as samples under the same conditions using Tenax tubes and were quantitatively analyzed by TD-GC/MS. Results: In the case of scented candles, the concentration of PM2.5 did not increase during combustion and after being extinguished by placing a cover on the candle. For the incense sticks, the concentration of PM2.5 averaged 1,901.27 ㎍/m3. After burning scented candles and incense sticks, some VOCs concentrations were increased such as ethyl acetate and BTEX (benzene, toluene, ethylbenzene, xylene). Conclusions: Therefore, when using scented candles, extinguishment by placing a cover on the candle can be expected to reduce PM2.5. It is advisable to avoid using incense sticks because PM2.5 concentration increases from the start of combustion.

총휘발성유기화합물 측정 직독식장비 정확도 향상을 위한 현장보정계수 활용 연구 (Preliminary Study on Effect of the Field Correlation Factor for Increasing of the Accuracy in a Direct Reading Instruments on Photoionization Detector for Total Volatile Organic Compounds)

  • 김성호;이광용;김수진;박해동
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.67-76
    • /
    • 2024
  • Objectives: Direct reading instruments (DRIs) are widely used by industrial hygienists and other experts for preliminary survey and identifying source locations in many industrial fields. Photoionization detectors (PIDs), which are a form of hand-held portable DRIs, have been used for a variety of airborne vaporized chemicals, especially evaporated hydrocarbon solvents. The benefits of PIDs are high sensitivity between each chemical, competitive price, and portability. With the goal of increasing the accuracy of logged PID concentrations, previous studies have performed tests for the assessment of single chemical compounds, not mixtures. The purpose of this preliminary study was to measure mixtures with a PID and charcoal tube at the same time and compare the accuracy between them. Methods: A chamber test was implemented with different mixtures of hydrocarbon chemicals (acetone, isopropyl alcohol, toluene, m-xylene) and levels in the range of 14 to 864 ppm. Three PIDs and charcoal tubes were connected to the chamber and measured the chemical mixtures simultaneously. A comparison of accuracy and the PID group of concentrations with manufacture correction factor (M_CF) and field correction factor (F_CF) applied was performed. Results: The accuracy of the PID concentrations data-logged from the PID did not meet the accuracy criteria except for the mixture level B and C logged from PID No. 2, which was 18% of all tests for meeting accuracy criteria. The mean and standard deviation (SD) of concentration (ppm) of the charcoal tube followed by each mixtures' level were 10.37±0.26, 155.33±5.28, 300.80±11.65, and 774.93±22.65, respectively. When applying F_CF into the PID concentrations, the accuracy increased by nearly 82%. However, in the case of M_CF, none met the accuracy criterion. Between the PID there were differences of logged concentrations. Conclusions: In this preliminary study, the concentration of a logged PID with F_CF applied was a better way to increase accuracy compared to applying M_CF. We suggest that additional research is necessary to consider environmental factors such as temperature and humidity.

이동형 스크러버를 이용한 암모니아 및 톨루엔의 제거 효율 (Removal Efficiency of Ammonia and Toluene using Mobile Scrubber)

  • 김재영;김장윤;이연희;김민선;김민수;김현지;류태인;정재형;황승율;김균;이진환
    • 한국환경농학회지
    • /
    • 제37권1호
    • /
    • pp.49-56
    • /
    • 2018
  • 본 연구는 국내에서 다량 취급되고 있는 암모니아 및 톨루엔을 흄 상태로 노출시킨 후 흡수/흡착방법을 달리한 이동형 스크러버를 이용해 각 유해화학물질의 제거효율을 비교 분석하였다. 이동형 스크러버는 기 개발된 장치를 개선하여 와류 세정에 의한 흡수, 유입풍속 조절의 장점을 살리고, 활성탄 및 카본필터를 통한 기체상 유해화학물질의 흡착방법 도입을 통해 단점을 보완하였다. 개선된 장치는 기초성능평가를 통해 적정 제어풍속이 검증되었고, 5% 암모니아수 용액을 흄 상태로 노출시켜 후드 흡입부, 송풍기 배출부 및 세정기가 정상 작동함을 확인하였다. 흡수/흡착방법에 따른 암모니아 제거효율은 90분 경과 후 C${\geq}$PCA>SWA 순으로 가장 우수한 SWA 군의 노출 농도별 제거 효율은 시간이 경과할수록 노출 농도와 무관하게 배출 농도는 증가되었고, 세정액의 pH는 산성에서 염기성으로 변화되었다. 또한, 시간 경과에 따른 노출 농도 별 세정액의 pH 변화와 배출구 농도 변화 사이에 0.9429~0.9491 수준의 정의 상관관계를 나타내었다. 흡착방법에 따른 톨루엔의 제거 효율은 초기 10분 경과 후 배출구농도에서 C>CMA${\geq}$GCA 순을 나타내다 90분 경과까지 일정한 농도로 유지되었다. 가장 우수한 GCA 군의 노출 농도별 제거 효율은 초기 10분 경과 시 노출 농도에 비례하여 배출 농도가 높은 경향이었다. 이와 같은 결과를 통해 개선된 이동형 스크러버는 중화반응에 의해 산성 또는 염기성 유해 화학물질의 제거 뿐 아니라, 활성탄 등의 흡착기능 개선을 통해 VOCs 제거에도 효과적이었다. 하지만, 실제 현장에서 활용이 가능하도록 세정액 pH를 지속적으로 유지하여 연속적으로 흡수 제거할 수 있는 방법과 노출되는 화학물질 농도와 흡착제의 관계에서 파괴점, 포화점, 흡착속도 등의 물리적인 요소가 추가적인 연구를 통해 도출되어야 할 것이다.

건강기능식품 중 잔류용매 분석법 개발 및 모니터링 (Analytical Method Development and Monitoring of Residual Solvents in Dietary Supplements)

  • 이화미;신지은;장영미;김희연;김미혜
    • 한국식품과학회지
    • /
    • 제42권4호
    • /
    • pp.390-397
    • /
    • 2010
  • Residual solvents in foods are defined as organic volatile chemicals used or produced in manufacturing of extracts or additives, or functional foods. The solvents are not completely eliminated by practical manufacturing techniques and they also may become contaminated by solvents from packing, transportation or storage in warehouses. Because residual solvents have no nutritional value but may be hazardous to human health, there is a need to remove them from the final products or reduce their amounts to below acceptable levels. The purpose of this study was to develop and evaluate an analytical method for the screening of residual solvents in health functional foods. Furthermore, the aim of this study was to constitute a reasonable management system based on the current state of the market and case studies of foreign countries. Eleven volatile solvents such as MeOH, EtOH, trichloroethylene and hexane were separated depending on their column properties, temp. and time using Gas Chromatography (GC). After determining the GC conditions, a sample preparation method using HSS (Head Space Sampling) was developed. From the results, a method for analyzing residual solvents in health functional foods was developed considering matrix effect and interference from the sample obtained from the solution of solvents-free health functional foods spiked with 11 standards solutions. Validation test using the developed GC/HSS/MS (Mass Spectrometry) method was followed by tests for precision, accuracy, recovery, linearity and adequate sensitivity. Finally, examination of 104 samples grouped in suits was performed by the developed HSS/GC/MS for screening the solvents. The 11 solvents were isolated from health functional foods based on vapor pressure difference, and followed by separation within 15 minutes in a single run. The limt of detection (LOD), limit of quantification (LOQ), recovery and coefficient of variation (C.V.) of these compounds determined by the HSS/GC/MS were found to be 0.1 pg/mL, 0.1-125 pg/g, 51.0-104.6%, and less than 15%, respectively. Using the developed HSS/GC/MS method, residual solvent from 16 out of 104 health functional products were detected as a EtOH. This method therefore seems t o be a valuable extension ofanalytical method for the identification of residual solvents in health functional food.

대기오염물질 제어를 위한 생물살수여과법의 운전인자와 성능평가 (Operating Parameters and Performance of Biotrickling Filtration for Air Pollution Control)

  • 원양수
    • 공업화학
    • /
    • 제16권4호
    • /
    • pp.474-484
    • /
    • 2005
  • 생물학적 방법에 의한 대기오염물질 처리는 기존의 처리방법을 대체할 수 있는 방법으로 각광을 받고 있다. 생물학적 처리방법은 유기화합물 또는 악취가 포함된 저농도 고유량의 공기를 처리하는데 효과적이다. 생물학적 처리 방법은 기존의 소각 또는 흡착 방법에 비해 여러 장점을 가지고 있다. 주요 장점으로 처리비용이 저렴하고, 2차 오염물질이 발생되지 않으며, 화학물질이 사용되지 않고, 에너지 사용이 적으며, 상온에서의 운전 등이다. 대기오염물질을 생물학적 방법으로 처리하는데는 생물여과법이 많이 이용되고 있으나 여러 제약이 있어 이를 해결할 수 있는 방법으로 생물살수여과법에 대한 개발연구가 수년 전부터 수행되어 왔다. 생물살수여과법은 생물여과법에 비해 다소 복잡하나 난분해성 물질이나 분해과정에서 산이 생성되는 경우 효과적으로 이용될 수 있다. 그러나 생물살수여과법을 이용한 대기중 VOC 처리에 대한 연구는 초기단계로서 효율적인 처리를 위해 많은 연구가 진행중이다. 본 연구에서는 대기오염제어를 위한 생물살수여과법의 기본 원리와 이론 및 실용적 내용에 대하여 소개하고자 한다. 특히 생물살수여과법의 운전인자와 성능에 미치는 영향인자에 대하여 중점적으로 다루었다.

생물학적 처리기술을 이용한 대기오염 제어 (Biotreatment Technologies for Air Pollution Control)

  • 원양수
    • 청정기술
    • /
    • 제13권1호
    • /
    • pp.1-15
    • /
    • 2007
  • 미생물을 이용하여 생물분해 가능한 휘발성유기물질과 악취물질을 처리하는 생물학적 대기오염처리 기술은 기존의 일반적으로 사용되고 있는 방법에 비해 상대적으로 최근에 개발된 방법이다. 생물학적 방법에 의한 대기오염물질 처리는 기존의 처리방법을 대체할 수 있는 방법으로 각광을 받고 있다. 생물학적 처리방법은 유기화합물 또는 악취가 포함된 저농도 고유량의 공기를 처리하는데 효과적이다. 생물학적 처리방법은 기존의 소각 또는 흡착 방법에 비해 여러 장점을 가지고 있다. 주요 장점으로 처리비용이 저렴하고, 2차 오염물질이 발생되지 않으며, 화학물질이 사용되지 않고, 에너지 사용이 적으며, 상온에서의 운전 등이다. 생물학적 방법중 생물여과법, 생물살수여과법, 생물세정법 세가지 방법이 널리 이용되고 있다. 이들 방법중 생물여과법이 가장 많이 이용되고 있으나 실제 적용에 있어 여러 제약이 있어 이를 해결하기 위한 생물학적 방법들에 대한 연구가 수년 전부터 수행되어 왔다. 생물살수여과법은 생물여과법에 비해 다소 복잡하나 난분해성 물질이나 분해과정에서 산이 생성되는 경우 효과적으로 이용될 수 있다. 본 연구에서는 대기오염제어를 위한 생물여과법, 생물살수여과법, 생물세정법의 기본원리와 이론 및 실용적 내용을 다루었다. 특히 생물학적 방법들의 운전 인자와 성능에 미치는 영향인자 및 비용평가 등에 대해 조사 분석하였으며, 생물살수여과법에 대해서는 좀 더 집중적으로 고찰하였다.

  • PDF

소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성 (Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station)

  • 김수진;함승헌;전정석;김원
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.140-151
    • /
    • 2019
  • 본 연구에서는 소방관들이 화재현장에서 복귀 후 소방청사 내에서 2차적으로 노출된 화학적 유해물질의 실내공기질을 평가하였다. 서울시에 소재한 4개 소방서를 선정하였고, 그 중 2개 소방서는 실제 화재현장에서 소방활동 종료 귀소 후에, 다른 2개 소방서는 대조군으로 설정하여 출동과 상관없이 평소 수준의 실내공기질을 측정하였다. 소방안전지도 전산시스템을 이용하여 서울시에서 발생하는 모든 화재사고에 대하여 24시간 모니터링을 실시하였고 중급규모 이상의 사고에서 실험군이 출동하게 되는 경우 귀소 후 바로 실내공기질을 측정하였다. 11개 유해물질 항목(미세먼지, 포름알데히드, 휘발성유기화합물, PAH, VCM, 산류, 석면, CO, CO2, NO2, O3)을 공정시험법에 따라 측정하였다. 유해물질 11종 중 3종이 국내·외 기준을 초과하였고 1종은 국외기준에 육박하는 것으로 확인되었다. 특히 총휘발성 유기화합물, 이산화탄소, 황산은 각 2.5배, 2.2배, 1.1배가 환경부 및 고용노동부 기준보다 높았다. 또한, 포름알데히드와 황산의 경우, 실험군보다 대조군에서 더 높게 측정되었다. 본 연구결과는 서울특별시 소방청사 내 실내공기질 개선 정책에 활용될 수 있을 것이다.

낙동강 수계의 섬유 및 화학 산업폐수로부터 발생하는 미량유해화학물질의 모니터링 (Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System)

  • 김만일;강미아
    • 지질공학
    • /
    • 제16권2호
    • /
    • pp.145-152
    • /
    • 2006
  • 다양한 산업의 발달은 우리 인간이 사용해야 하는 수자원으로 여러 가지 형태의 위해성을 함유하는 유해화학물질들의 수적 양적 증가를 초래하였다. 이로 인해 효율적인 수자원의 이용을 위해서는 수자원으로 유입되는 오염원의 사전 처리가 필수적인 것으로 인지되어 국내에서도 수자원으로 유입되는 오염물질에 대해 총량으로 방류업체의 수질을 규제하기 시작했다. 그러나 아직까지도 규명되지 않은 화학물질들이 대다수를 차지하므로 이에 대한 모니터링이 매우 중요한 역할로 자리하고 있다. 본 연구에서는 낙동강 수계로 유입되는 섬유 및 화학 산업폐수를 중심으로 미량유해화학물질을 계측하여 이들이 낙동강 수계에 미치는 유해성을 검토하였다. 대상으로 한 7개 업체로부터의 유입수와 방류수에서 검출되는 VOCs(volatile organic compounds) 중에서는 클로로포름(chloroform)이 가장 높은 빈도로 검출되었으며, 동일한 업체에서도 노출수준이 일정하지 않아 이의 관리에 어려움이 예상된다. 그러나 이들 업체의 방류수가 유입되는 하수처리장에서는 콜로로포름의 처리효율이 높아(88% 이상) 낙동강 수계의 영향은 그리 크지 않을 것으로 추정된다. 한편, 섬유/화학관련 산업체의 유입수와 방류수로부터 노출되는 EU지정우선물질에 대해 조사한 결과, 검출현황에 대한 일정한 경향을 찾을 수 없을 뿐만 아니라 국내자료의 축적도 거의 없는 상태임을 감안하여 지속적인 모니터링을 통해 국가정책에 활용 할 수 있는 자료구축을 해 나가야 할 것이다.