• Title/Summary/Keyword: Volatile Organic compounds

Search Result 1,281, Processing Time 0.03 seconds

Measurements of Volatile Organics, Newly Designated Offensive Odorants in Korea in 2008 and 2010: a Case Study on Gutter System (2008년과 2010년 지정 VOC 계열 신규악취성분들에 대한 분포특성 조사: 도심 하수환경 중 빗물받이에 대한 연구)

  • Ahn, Ji-Won;Hong, One-Feel;Lee, Eun-Hee;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.305-317
    • /
    • 2010
  • In this research, a total of 11 newly designated offensive odorants in Korea in 2008 and 2010 (styrene (S), toluene (T), p-xylene (p-X), methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), butyl acetate (BuAc), isobutyl alcohol (i-BuAl), propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) were selected as target compounds and analyzed from two types of gutter system in the urban environment. Because of the environmental significance of these compounds as offensive odorants, the results are meaningful enough to explore their behavior and distribution in the urban environmental systems. In the course of this study, samples were collected three times a day from two different gutter systems representing the wet (W) and dry (D) conditions. A large fraction of volatile organic compounds (VOCs) data fell into method detection limit (MDL) range with exceptions of toluene, p-xylene, and methyl ethyl ketone. In contrast, the results of organic fatty acids were distinguished by the relative dominance of butyric acid and propionic acid over others. If the concentration data of all odorants were converted into odor intensity (OI), the results of aromatics, ketones, acetate, and alcohol groups approached zero level. However, odor intensity of organic fatty acids was noticeably higher with the value of 2.8 (on average) from both W and D system, suggesting their potent roles as odorants in gutter system.

Volatile Organic Compounds of Black Locust Logs Heated at $250^{\circ}C$

  • Lu, Jianxiong;Park, Sang-Bum;Lee, Hee-Young;Kang, Ho-Yang
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.3
    • /
    • pp.198-204
    • /
    • 2009
  • Less used small diameter logs of black locust were heated at $250^{\circ}C$ for improving utilization. The volatile compounds emitted by the heated logs were analyzed. Their effect of formaldehyde absorption was evaluated with PB. Ester and acid compounds were dominant in content. Especially, methyl acetate and acetic acid showed the highest contents. The total content of aromatic compounds decreased as heating time increased. Amoung ketone compounds, The contents of 2-propanone, 2-pentanone, 3-petanone, 3-hexanone and cyclopentenone decreased with the increase of heating time, but the others did not. The contents of the chemicals, furfural and 3-pentanol, increased with heating time, while that of 2-methyl butanal decreased. It was hard to say that formaldehyde was absorbed by the heated black locust samples. Some decorative goods were designed with the heated logs.

  • PDF

Organic Acids and Volatile Flavor Compounds in Traditional Andong Sikhe (전통 안동식혜의 유기산 및 향기성분)

  • Woo, Hi-Seob;Choi, Cheong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 1995
  • Andong Sikhe in Korea was prepared and fermented at 5$^{\circ}C$ and the taste and flavor compounds were evaluated. Major flavor components were identified by gas chromatography-mass spectrometer as camphene, sabinene, 1-(1, 5-dimethyl-4-hexyl)-4-methyl-benzene, alpha-zingibirene, farnesene, 2, 6-bis(1, 1-dimethylethyl)-4-metethyl-phenol, beta-sesquiphellandrene, calalene, tetradecanoic acid, and 9, 12-octadecanoic acid. The concentration of nonvolatile organic acid such as lactic acid, oxalic acid and citric acid were 18.10mg/100g, 1.04mg/100g and 1.37mg/100g, respectively, and those of other nonvolatile organic acid were a little. The pH and acidity of Andong Sikhe were 4.06 and 0.32 during fermentation and storage.

  • PDF

Volatile organic compounds of pyroligneous liquor of bamboo sprout produced in damyang-gun (담양군 죽초액의 휘발성성분 분석)

  • Lee, Eunsil;Jang, Hyejin;Lee, Songjin;Ha, Jaeho
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.299-306
    • /
    • 2013
  • Pyroligneous liquor as a byproduct from charcoal production of bamboo sprout produced damyang-gun has the broad benefits such as improvement of soil quality, plant growth control and is mainly used for the treatment of atopic dermatitis, fungi and many other skin diseases. In this study, flavor compounds of pyroligneous liquor from bamboo sprout produced in Damyang-gun were analyzed and compared using three different methods including direct analysis (DA), headspace solid phase microextraction (HS-SPME) and stir bar sorptive extraction (SBSE). Simultaneously, the analytical conditions of GC-MS for the determination of volatile compounds were optimized. Based on volatile organic compounds detected by GC-MS, SBSE and SPME methods showed higher sensitivity than direct analysis. Major compounds of pyroligneous liquor were cresol, guaiacol, p-ethyl guaiacol and syringol. These phenolic compounds are reported as the useful chemicals with medicinal activity.

Evaluation of Fugitive Emission Characteristics of Airborne Volatile Organic Compounds from Different Source Categories (발생원 유형에 따른 공기 중 휘발성 유기화합물의 비산배출 특성 평가)

  • 백성옥;김미현;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.363-376
    • /
    • 2003
  • In this study, the fugitive emission characteristics of airborne volatile organic compounds from different source categories were evaluated with respect to the concentrations measured in the vicinity of the sources. A total of 22 different sources were investigated, including gasoline storage and filling stations, painting spray booth, laundry, printing officer, textile industries, and a number of environmental sanitary facilities such as landfill, wastewater treatment and incineration plants. The target VOCs included 83 individual compounds, which were determined by adsorption sampling and thermal desorption coupled with GC/MS analysis. Overall, the aliphatic compounds appeared to be the most abundant class of compounds in terms of their concentrations, followed by aromatic, and halogenated hydrocarbons. As a single compound, however, toluene was the most abundant one, explaining 11% of the total VOC concentrations as an average of all the dataset. Among source categories, petroleum associated sources such as gasoline storage/filling stations, and laundry factory were identified as the most significant sources of aliphatic hydrocarbons, while aromatic VOCs were dominantly emitted from the sources handling organic solvents, such as painting booth, printing offices, and textile dyeing processes. However. there was no apparent pattern in terms of the contributions of eath group to the total VOCs concentrations in environmental sanitary facilities. It was also found that the activated carbon adsorption tower installed for the VOC emission control in some facilities do not show any effective performances, which may result in the increased VOC levels in the ambient atmosphere.

Influence of Organic Matter and Temperature on the Sorption of Volatile Organic Compounds on Soil (토양 흡착에 대한 유기탄소와 온도의 영향)

  • 김희경
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.57-59
    • /
    • 1998
  • The headspace method has been acknowledged as a cost-effective and convenient method to analyze volatile organic compounds(VOCs) in soil. The headspace analysis is based on equilibrium partitioning of VOCs among water, air and soil in a closed system. However, the headspace method cannot be applied to soils where most of the VOCs remain sorbed even at high temperature. In this study, it was investigated how the sorption characteristics of VOCs varied with soil with different organic carbon contents and temperature. This study showed that all the VOCs were volatilized, not sorved, only in the soil with 5% organic carbon at 45$^{\circ}C$ or higher. Some fraction of VOCs remained in soil with 8% organic carbon at $65^{\circ}C$ of higher. Most of the VOCs remained sorbed in soil with 12% organic content even at 95$^{\circ}C$. This result suggested that the headspace method can be applied only to soils with little organic carbon content (less than 5%). In this case, 45$^{\circ}C$ seems to be high enough to volatilize all the VOCs from soil. Large particles still showed a significant sorption capacity for VOCs from soil. Large Particles still showed a significant sorption capacity for VOCs despite of their low level of organic carbon content. It was also shown that the organic carbon sorption coefficients (Koc) of VOCs varied with soils with different organic carbon content. This suggests that not only the organic matter content of soil but also the property of the organic matter in soil influence the sorption of VOCs to soil.

  • PDF

The hydrocarbon concentration distribution in the contaminated site using geospatial analysis

  • Lee, Ju-Young;Yang, Jung-Seok;Choi, Jae-Young;Krishinamurshy, Ganeshi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.909-910
    • /
    • 2007
  • The volatile organic compounds exposure is governed by the source distance and dispersion of the pollutant into air and groundwater. The purpose of this study was to validate suggested models for the prediction of concentration distributions. The study design was organized into different methods to simulate industry site. The distribution models generally showed a fair agreement with measured data. For graphical representation of concentration of volatile hydrocarbon, it has to obtain a continuous representation of the contamination of the site. Therefore, the used interpolative methods examined for this project are the IDW(inverse Distance Weighting) and kriging method. In the results, in summary, all two different methods can be used to quantify exposures at a particular source area, and thus provide, a solid foundation for making risk-based decisions. All the calculations can be performed using Excel's built-in functions, and the capabilities of geospatial analysis allow the results to be displayed visually. However, anyone who uses these methods should understand all of the assumptions and limitation.

  • PDF

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

Calculation of Film Diffusion Coefficients and Surface Diffusion Coefficients of Volatile Organic Compounds Using Activated Carbon Adsorption Model and Small Column Test (활성탄 흡착모델과 칼럼실험을 통한 Volatile Organic Compounds의 막확산계수와 표면확산계수의 도출)

  • Lee, Byoung-Ho;Lee, Joon-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.72-80
    • /
    • 1999
  • Separation of VOCs(Volatile Organic Compounds) in Water Using Activated Carbon is known to be effective. Activated Carbon has been and will be employed in many water treatment plants. Simplified plug flow homogeneous surface diffusion model(PFHSDM) has been used to predict adsorption of organic matter. Finite Element Method(FEM) was used to analyze the model. Out of water quality control substances, benzene, toluene and tetrachloroethylene were used in the small column test. Film diffusion coefficients and surface diffusion coefficients were obtained from the column test, and were compared with the modeling results. Mc Cune, Williamson, William and Kataoka model, were compared with film diffusion coefficients obtained in the test. McCune model was fitted best for those VOCs used in this experiment. Film diffusion coefficients of VOCs obtained were benzene 0.265 cm/min, toluene 0.348 cm/min and tetrachloroethylene 0.298 cm/min. Surface diffusion coefficients of VOCs obtained were benzene $6.36{\times}10^{-8}cm^2/min$, toluene $3.20{\times}10-8cm2/min$, and tetrachloruethylene $4.94{\times}10^{-8}cm^2/min$.

  • PDF

Analysis of Volatile Organic Compounds in Kinnchi Absorbed in SPME by GC-AED and GC-MSD (SPME로 포집한 김치 휘발성분의 GC-AED및 GC-MSD에 의한 동정)

  • 하재호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.3
    • /
    • pp.543-545
    • /
    • 2002
  • The volatile compounds in kimchi adsorbed with solid phase microextraction (SPM) were analyzed by using a gas chromatograph-atomic emission detector (GC-AED) and a gas chromatograph-mass spectrometer (GC-MSD). The volatile compounds were effectively adsorbed in SPME. Twenty five compounds such as dimethyl-sulfide were identified by GC-MSD and some of these were further confirmed to contain a sulfur and a nitrogen by GC-AED.