• Title/Summary/Keyword: Vital sign

Search Result 300, Processing Time 0.027 seconds

Remote Vital Signal Monitoring System Based on Wireless Sensor Network Using Ad-Hoc Routing

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.67-70
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons, and transfer his/her health status wirelessly in Ad-hoc network to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.

A Study of Sensing Locations for ECG Monitoring Clothing based on the Skin Change rate (체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구)

  • Cho, Hakyung;Cho, Sang woo
    • Fashion & Textile Research Journal
    • /
    • v.17 no.5
    • /
    • pp.844-853
    • /
    • 2015
  • Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20' with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

A Clinical Study on the Factors that Influence Functional Evaluation of Stroke (중풍의 기능평가에 영향을 미치는 요인에 관한 임상적 고찰)

  • 박숙자;권정남;김영균
    • The Journal of Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.73-90
    • /
    • 2002
  • Objectives: This study investigated significant factors that influence functional evaluation of stroke so as to be a fundamental data for estimating prognosis of stroke patients. Methods: 204 patients were studied within 7 days of admission, after the diagnosis of stroke through brain CT scan, brain MRI scan and clinical observations. They were hospitalized in the oriental medical hospital of Dongeui University from February to July in 2001. They were examined at the early stage of onset, after 2 weeks, 4 weeks and 6 weeks, and measured for average mark and the degree of improvement by using the Activity Index. Results: Ischemic stroke, past history of stroke, hypertension, diabetes mellitus, risk factor of obesity, non-professional emergency treatment and hospitalizing time after 1 day from onset, high blood pressure, tachycardia pulse and high blood sugar in abnormal vital sign in acute stage, conscious, cognitive or communication disorder, motor aphasia, dysphagia, constipation for more than 3 days, urinary incontinence, visual field defect, insomnia, and chest discomfort in early stage of onset had a negative influence on functional evaluation. Conclusions: Type of stroke, past history, risk factors, emergency treatment and hospitalizing time after onset, abnormal vital sign and intercurrent symptoms in Acute stage were relevant factors in predicting functional evaluation of stroke.

  • PDF

Measuring the Level of Health Literacy and Influence Factors: Targeting the Visitors of a University Hospital's Outpatient Clinic (건강정보 이해능력 수준과 영향요인에 대한 고찰: 대학병원 외래 방문객을 대상으로)

  • Kim, Jeongeun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: The objective of this research was to measure health literacy level of the visitors of a university hospital's out patient clinic and to consider its influence factors. Methods: Subjects were 400 visitors in an outpatient clinic of a university hospital. By using self-report questionnaire which included Newest Vital Sign (NVS) and general information inquiry, the level of health literacy and its influence factors were measured. The data were analyzed by using t-test, ANOVA, and Pearson's correlation. Results: The NVS score of subjects was $3.54({\pm}1.91)$ out of maximum 6 scale. The factors that have significant relationships with the health literacy were age, sex, marital status, educational background, monthly income, health information source, number of diseases, number of medications and drinking status. Participants who are men, in old age, having lack of supportive relationship, having low levels of education, having low income, having more comorbid diseases & medications, tend to have lower NVS score compared to others. Conclusion: We suggest extending our research results for evaluating the risky group to improve the health literacy and to develop the strategic methods for better health outcomes.

Effect of canine electroacupuncture anesthesia on changes of vital signs and blood gas values (개의 전침마취가 Vital sign 및 혈액가스치 변화에 미치는 영향)

  • Lim, Yeon-Soo;Song, Kun-Ho;You, Myung-Jo;Seo, Jee-Min;Kim, Myung-Chul;Kim, Duck-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.1
    • /
    • pp.157-163
    • /
    • 2003
  • The present study was performed to elucidate the effect of canine electroacupuncture anesthesia on vital signs and blood gas values. Groups were divided into experimental (electroacupuncture: EA) and control (ketamine) groups. The vital signs (body temperature, respiration rate and pulse) and blood gas values (pH, $pCO_2$ and $pO_2$) of venous and arterial blood were determined. Body temperatures of EA group were significant higher than than of ketamine group at 15 min., 30 min., 45min. and 60 min. (p<0.05) after anesthesia, respectively. The respiration rates of EA group were higher than those of ketamine group, however, significant differences were not observed between both groups. The pulses of EA group were significant higher than those of ketamine group at 5 min. (p<0.05), 10 min. (p<0.01), 15 min. and 30 min. (p<0.05) after anesthesia, respectively. The arterial and venous blood pHs of ketamine group were slightly higher than those of EA group, respectively, however, no significant differences were found between both groups. Significant differences were not observed between both groups in the arterial and venous blood $pCO_2$, respectively. The arterial blood $pO_2$ of EA group was significant higher than those of ketamine group at 5 min. (p<0.05) after anesthesia. No significant differences were observed between both groups in the venous blood $pO_2$. These results suggest that the changes of vital signs and blood gas values of EA group are similar to those of ketamine group with the exception of changes in the body temperature, pulse and arterial blood $pO_2$.

The Effects of Music Therapy on State Anxiety and Vital Sign (음악요법이 상태불안과 활력징후에 미치는 효과)

  • Lee, Jung-Hee;Jung, Hyun-Teak;Kim, Eun-Mi;Hwang, Ok-Nam
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.9 no.1
    • /
    • pp.64-71
    • /
    • 2006
  • Purpose: This study has tried to find out the effects of music therapy on anxiety of surgery patients during operation under regional anesthesia. In order to find out the effects, this research design was used nonequivalent control group non-synchronized design. Method: The subjects were the sixty inpatients under regional anesthesia in K hospital. They were assigned to two groups, thirty to the experimental group and thirty to control group. The data were collected using the Visual Analogue Scale(VAS) for State Anxiety and vital sign. The Experimental group received favorite music of the 4 different genre. The control group were inserted ear plug during operation. Data were analyzed by $X^2$-test, T-test, ANOVA and Repeated Measured ANOVA of the SPSS WIN (12.0) version program. Results: 1) Hypothesis 1: The hypothesis "that the figure for state anxiety of the experimental group provided with music therapy would be lower than that of the control group" was confirmed(F=0.27, P=0.01). 2) Hypothesis 2 : Three subordinating hypotheses were established in order to verify the hypothesis "that the figures for vital sings of the experimental group provided with such as music therapy would be lower than those of the control group." were rejected. Conclusion: Music therapy can be regarded as an effective nursing intervention that relieves operative anxiety of surgical patients under regional anesthesia.

  • PDF

Remote Vital Sign Monitoring System Based on Wireless Sensor Network using Ad-Hoc Routing (애드혹 라우팅을 이용한 무선센서네트워크 기반의 원격 생체신호 모니터링 시스템)

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.426-429
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients, was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons and transfer his/ her health status wirelessly in Ad-hoc network, to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.

  • PDF

Real-time Vital Signs Measurement System using Facial Image Data (안면 이미지 데이터를 이용한 실시간 생체징후 측정시스템)

  • Kim, DaeYeol;Kim, JinSoo;Lee, KwangKee
    • Journal of Broadcast Engineering
    • /
    • v.26 no.2
    • /
    • pp.132-142
    • /
    • 2021
  • The purpose of this study is to present an effective methodology that can measure heart rate, heart rate variability, oxygen saturation, respiration rate, mental stress level, and blood pressure using mobile front camera that can be accessed most in real life. Face recognition was performed in real-time using Blaze Face to acquire facial image data, and the forehead was designated as ROI (Region Of Interest) using feature points of the eyes, nose, and mouth, and ears. Representative values for each channel of the ROI were generated and aligned on the time axis to measure vital signs. The vital signs measurement method was based on Fourier transform, and noise was removed and filtered according to the desired vital signs to increase the accuracy of the measurement. To verify the results, vital signs measured using facial image data were compared with pulse oximeter contact sensor, and TI non-contact sensor. As a result of this work, the possibility of extracting a total of six vital signs (heart rate, heart rate variability, oxygen saturation, respiratory rate, stress, and blood pressure) was confirmed through facial images.

An Adaptive Polling Algorithm for IEEE 802.15.6 MAC Protocols (IEEE 802.15.6 맥 프로토콜을 위한 적응형 폴링 알고리즘 연구)

  • Jeong, Hong-Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.5
    • /
    • pp.587-594
    • /
    • 2012
  • IEEE 802.15.6 standard technology is proposed for low-power wireless communication in, on and around body, where vital signs such as pulse, blood pressure, ECG, and EEG signals are transmitted as a type of data packet. Especially, these vital signs should be delivered in real time, so that the latency from slave node to hub node can be one of the pivotal performance requirements. However, in the case of IEEE 802.15.6 technology data retransmission caused by transmission failure can be done in the next superframe. In order to overcome this limitation, we propose an adaptive polling algorithm for IEEE 802.15.6 technology. The proposing algorithm makes the hub to look for an appropriate time period in order to make data retransmission within the superframe. Through the performance evaluation, the proposing algorithm achieves a 61% and a 73% latency reduction compared to those of IEEE 802.15.6 technology in the environment of 70% traffic offered load with 10ms and 100ms superframe period. In addition, the proposing algorithm prevents bursty traffic transmission condition caused by mixing retransmission traffic with the traffic reserved for transmission. Through the proposing adaptive polling algorithm, it will be possible to transmit time-sensitive vital signs without severe traffic delay.