Spectrophotometric evaluation of restorative composite shades and their match with a classical shade guide

  • Rafael Melara;Luciana Mendonca;Fabio Herrmann Coelho-de-Souza;Juliana Nunes Rolla;Luciano de Souza Goncalves
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.60.1-60.8
    • /
    • 2021
  • Objectives: The aim of this study was to verify the match between 5 shades of composites from different manufacturers with a shade guide and among the systems using a portable spectrophotometer. Materials and Methods: Shade measurements were performed on specimens of Z350 XT (3M ESPE), Charisma Diamond (Heraeus Kulzer GmbH), Esthet X-HD (Dentsply Caulk), and Empress Direct (Ivoclar-Vivadent) for shades A1, A2, A3, B1, and C3 using a Vita Easyshade spectrophotometer (Vita Zahnfabrik) against a white background. Corresponding shades of Vitapan Classical (Vita Zahnfabrik) guide were measured likewise and shade variation (ΔE) was calculated based on International Commission on Illumination L*a*b* parameters. The ΔE of the composites in each shade was compared by one-way analysis of variance and Tukey's post hoc test (α = 0.05). Results: All composites presented ΔE > 3.7 compared with the shade guide. Variation in shades A3, B1, and C3 was significantly different for all composites. ΔE of Z350 XT was significantly lower for A1 than for the other shades, whereas ΔE of Z350 XT and Charisma Diamond were significantly lower for A2 than for the other shades. Conclusions: No composite shade matched with the shade guide. Equivalent shades of the restorative composite from different manufacturers may show clinically noticeable ΔE.

광중합형 복합레진과 shade guide의 색차에 관한 연구 (A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides)

  • 임경민;이민호;송광엽
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.13-22
    • /
    • 2009
  • 심미적인 특성을 가진 복합레진은 전치부 수복용 재료로 많이 이용되고 있다. 복합레진 수복 시 만족스러운 결과를 얻기 위해서는 색조의 선택이 중요한 역할을 한다. 현재 대부분의 수복용 복합레진은 Vita Lumin 색조견본(shade guide)이나 각각의 회사에서 제공하는 색조견본을 사용하고 있으나, 색조 견본 사이의 색차와 수복물과 견본 사이에 색차가 예상되어 그 차이를 규명하여 임상적인 선택 시에 도움이 되고자 하였다. 4종의 광중합 복합레진(Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), $Esthet{\cdot}X$ ($E{\cdot}X$))과 A2와 A3의 색조 견본을 사용하였다. 각 재료마다 3개의 시편과 1개의 색조 견본을 제작하였다. Teflon 주형(깊이 1.35 mm, 직경 8 mm)에 각각의 복합레진을 채우고 응축한 후에 중합하여 젖은 사포로 연마하였다. 색조 견본을 연마용 stone과 고무를 이용하여 1.35 mm 두께로 연마하였다. 컴퓨터에 의해 조절되는 spectrophotometer(color i5, GretagMacbeth, USA)를 이용하여 시편과 색조견본의 색의 특성을 CIELAB coordinates ($L^*$, $a^*$, $b^*$)로 평가하였다. CIELAB 계측을 통하여 복합레진과 색조 견본의 색차(${\Delta}E^*ab$)를 비교 평가 하였다. 광원으로는 CIE standard D65를 사용하였다. 다음과 같은 결과를 얻었다. 1. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편의 $L^*$, $a^*$, $b^*$ 값 간에 유의할 만한 수준의 차이를 나타냈다(p<0.05). 2. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 3. 동일한 shade로 설계된 여러 제조회사의 복합레진과 제조회사에서 제공되는 shade guide 및 Vita Lumin shade guide 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 4. 임상에서 보다 나은 색 조화를 얻어 심미성을 향상시키기 위해서는 실제 수복물로 제작한 custom shade guide의 제작이 필요할 것으로 생각된다. 제조사에 의해 제공되는 색조 견본이나 Vita Lumin 색조 견본은 임상의에게 복합레진의 색조 선택 시에 정확한 기준을 제공하지는 않았고, 대부분의 제품에서 인지할 수 있는 색차가 있었다. 그러므로 보다 나은 색조 선택을 위해 수복용 레진으로 제작한 맞춤형 색조 견본을 사용하는 것을 추천한다.

수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가 (THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY)

  • 김이경;조인호;신수연
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

색조 선택 시스템을 이용한 shade guide의 색조 분석 (Evaluation of shade guide using digital shade analysis system)

  • 이승택;이종혁;신수연
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.1-11
    • /
    • 2009
  • 연구목적: 심미 수복을 위한 색상 결정 방법으로는 색견본 (shade guide)과 치아를 눈으로 직접 비교하는 기존의 비색법과 최근 소개되기 시작한 색상 측정용 기기를 사용하는 방법이 있다. 비색법은 치과의사들과 기공사들 간의 색조 선택에 일관성이 결여되어 있는 등 많은 문제점이 지적되고 있지만 아직도 이러한 방법에 의한 색상 결정과 결정 색상에 대한 표현 방식이 임상 치의학에 적용되고 있다. 본 연구의 목적은 진료실과 기공소에서 사용하고 있는 색견본이 같은 값을 가지는지 ShadeEye - $NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan)로 확인하고 또한 이 측정 기기의 두 가지 모드가 동일한 shade tab을 같은 값으로 인식하는지 확인하고자 하였다. 연구재료 및 방법: 첫 번째 실험에서는 모두 8개의 Vita Lumin Vacuum shade guide (Vident Inc., California, USA)를 모아 그 중 A1과 B1 shade tab을 각각 5회씩 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 하였고 두 번째 실험에서는 치과 진료실과 기공소에서 실제 사용하고 있는 Vita Lumin Vacuum shade guide를 각각 12개씩 모아 역시 A1과 B1 shade tab을 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 실시하였다. 결과: 첫 실험에서 8개의 색견본의 A1과 B1의 5회씩 측정에서 두 가지 mode에서 모두 채도 (shade), 명도 (value), 색상 (hue)에서 유의한 차이를 보였다(P<.05). 두 번째 실험에서는 진료실에서 사용하는 색견본과 기공소에서 사용하는 색견본 사이에는 통계적으로 유의한 차이를 보이지 않았으나, A1의 porcelain mode 에서 채도가 유의한 차이를 보여 (P<.05), 같은 shade tab이라 할지라도 채도에서 차이가 날 수 있음을 보였다. 결론: ShadeEye-$NCC^{(R)}$의 mode에 따라 동일한shade tab을 다른 값으로 인식하는 것으로 나타나 진료실과 기공소 간에 동일한 mode로 사용하는 것이 필요할 것으로 사료된다.

분광색채계측기를 이용한 Vita Shade 광중합형 복합레진의 색상 비교 (COMPARATIVE EVALUATION OF LIGHT-CURED COMPOSITE RESINS BASED ON VITA SHADE BY SPECTROCOLORIMETER)

  • 조경이;황인남;최홍란;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.424-432
    • /
    • 1998
  • To get a satisfactory result in the composite resin restorations, it is necessary to choose correct shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guide or Bioform shade guide, but color differences might be expected even using the same shade in various materials. In this study, five kinds of light-cured composite resins with A2 and B3 shade were used to measure and compare the color each other while one porcelain served as a control. All composite resins (Spectrum TPH (SP), VeridonFil- Photo (VE), Z100 (Z100), Charisma (CH), Prodigy (PRO)) were filled in to the metal mold (12 mm diameter, 2 mm depth), followed by compression, polymerization and polishing with wet sandpaper. The specimens of porcelain were fabricated by using the refractory mold for porcelain. After 24 hours, the specimens were placed on the spectrocolorimeter and spectral reflectance were measured under CIE illuminant D65. After measuring the values of $L^*$, $a^*$, $b^*$ and ${\Delta}E^*$, following results were obtained; 1. The $L^*$, $a^*$ and $b^*$ values of both shade of porcelain specimens showed significantly higher than those of resin specimens(p<0.05). 2. In comparing the resin specimens of the A2 shade, differences were significant except $L^*$ values of SP-CH and PRO-VE, $a^*$ values of the VE-SP and $b^*$ values of the VE-Z100 and SP-PRO(p<0.05), 3. In comparing the resin specimens of the B3 shade, differences were significant except $L^*$ values of PRO-SP, $a^*$ values of the SP-PRO and Z100-VE and b* values of the PRO-SP(p<0.05). 4. In comparing the resin specimens of the A2 shade, color differences between materials (${\Delta}E^*$) showed the lowest value of 1.66, and the highest was 5.16. ${\Delta}E^*$ values of the materials of VE-PRO, CH-PRO, SP-PRO, SP-Z100 and SP-CH were lower than 3.3. 5. In comparing the resin specimens of the B3 shade, the lowest value of the ${\Delta}E^*$ was 0.57 and the highest was 5.92. ${\Delta}E^*$ values of Z100-CH and SP-PRO were lower than 3.3. The present study revealed there was perceptible color difference between materials even if they have the same designated shade based on Vita shade guide. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

  • PDF

가시광선영역에서 shade guide에 따른 광투과도 특성 연구 (ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES)

  • 최근배;박찬운;송창용;고석민
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Perception and satisfaction of the face and the need for aesthetic dental treatment in the college students

  • Lee, Seung-Hun
    • 한국치위생학회지
    • /
    • 제17권1호
    • /
    • pp.89-98
    • /
    • 2017
  • Objectives: The purpose of the study is to investigate the perception and satisfaction of faces and the need for aesthetic dental treatments in college students. Methods: A self-reported questionnaire was completed by 247 college students in Suncheon from August 29 to September 2, 2016. The questionnaire consisted of satisfaction of face (16 items), perception of the face (7 items), need for aesthetic dental treatment (3 items), and general characteristics of the study subjects (8 items). Tooth shade was measured using a shade guide (VITA classical shade guide, VITA North America, Chicago, USA). Data was analyzed using t test, ANOVA, and post hoc $Scheff{\acute{e}}$ test. Results: The students were satisfied with eye, mouth corner, and lip, but they were not satisfied with tooth shade, bilateral symmetry of face, and angle of jaw. The students tended to be concious of perception of others. Their most common tooth shade was orange and yellow. They preferred to have a brighter tooth color. Conclusions: To satisfy the needs of patients, it is important to understand the perception and satisfaction of face and the need for aesthetic dental treatment.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

발거된 자연치와 5종 Shade Guide의 색채 계측기를 이용한 색상 비교 (COLORIMETRIC ANALYSIS OF EXTRACTED HUMAN TEETH AND FIVE SHADE GUIDES)

  • 황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.769-781
    • /
    • 1997
  • The tristimulus values of 180 extracted maxillary and mandibular anterior teeth were measured by colorimeter. And it were colnverted to Munsell color order system(Hue, Value, Chroma) and CIE $L^*a^*b^*$ color coordinates. The commonly used Vita, and Bioform shade guides, 2 composite resin shade guides(Prisma APH and Z-100), and a glass-ionomer shade guide(Fuji II) were compared with these teeth. At the middle facial surface, color distributions of teeth were Hue(0.56YR to 9.77Y), Value(2.46 to 7.9), and Chroma(0.14 to 2.02). And the aberaged values and standard deviations for $L^*a^*b^*$ were $63.18{\pm}10.44$, $1.11{\pm}1.66$, and $5.79{\pm}2.36$. The shade guide did not match well with the color space of the human teeth. Especially, the lacks of the Yellow-red Hues and higher values were prominent. Compare with other measurements, the Hues of the teeth measured in this study were broadly distributed(most of ranges in Y and YR were included), while the Value and chroma were shown to the lower.

  • PDF