• Title/Summary/Keyword: Visual Sensitivity

Search Result 371, Processing Time 0.034 seconds

A Display-based Visual Stimulator for Psychophysical and Electrophysiological Color Sensitivity Measurements

  • Hwang, Jisoo;Park, Seung-Nam;Park, Cheol-Min;Lee, Geun Woo;Kim, Kiseong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.145-150
    • /
    • 2012
  • We present a display-based visual stimulator for psychophysical and electrophysiological visual sensitivity measurements. The stimulator offers various psychophysical visual stimuli and transfers the signals from external devices along with the stimulation signals to an electrophysiological recorder. As an experimental demonstration, we perform a visual sensitivity experiment in the mesopic vision range by using the display-based stimulator. The intensity of the steady-state visual evoked potential is observed to correlate with the luminance of the flickering visual stimulation. For the psychophysically determined detection thresholds, we determine the mesopic luminance, showing agreement with the perceived brightness within the uncertainty of the luminance measurement.

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

Effects of Transmittance of Diffusive Blur on Visual Acuity and Contrast Sensitivity (확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향)

  • Yang, Seok-Jun;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.355-362
    • /
    • 2015
  • Purpose: To investigate the effects of the transmittance of diffusive blurson visual acuity and contrast sensitivity. Methods: Visual acuity and contrast sensitivity were measured by using Optec$^{(R)}$ 6500 in Healthy 30 subjects aged $22.83{\pm}0.50$ (male 13, female 17) who were recruited from university students. Cataract simulator was used as a tool for diffusive blur. Visual acuity and contrast sensitivity were measured with varying the transmittance of diffusive blur in order to simulate progression of cataract and concentration in fog. Results: Visual acuity was reduced proportionally with decreasing the transmittance of the diffusive blur as follows: $VA(T)=1.84{\times}10^{-2}T-0.645$. Contrast sensitivity was decreased in all spatial frequencies. Contrast sensitivity in a high spatial frequency band was a greater effect and was off the normal range of contrast sensitivity. The peak of contrast sensitivity was moved in the direction to low frequency. From an intersection point of contrast sensitivity function, we could calculated the transmittance of the diffusive blur being off the normal range and the shift to peak spatial frequency. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd at transmittance of about 78.70%, the contrast sensitivities for all frequencies at transmittance of about 69.71% were deviated from the normal range. Conclusions: The transmittance of diffusive blur causes a reduction in visual acuity and contrast sensitivity, a deviation of normal range of contrast sensitivity, and a shift of peak contrast sensitivity. Therefore the more attention is required when suffering from cataracts or driving in fog.

Persuasive Effects Depending on the Type of Creative Ads in Social Media and User Sensitivity and Empathy (SNS 미디어의 크리에이티브 유형과 사용자의 민감성 및 공감적 이해에 따른 설득 효과)

  • Kim, Jae-Young
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.145-154
    • /
    • 2022
  • The purpose of this study is to investigate the difference in advertising effect of visual rhetoric type of Facebook ads depending on the user sensitivity and level of empathy. The experiment was designed as a between-subjects factorial design (visual rhetoric type) × 2 (brand sensitivity) × 2 (level of empathic understanding). The results of the experiment performed to analyze the strategies of Facebook ads for ads effectiveness can be summarized as follows: a three-way interaction effect for persuasive effects was found among the type of visual rhetoric, brand sensitivity, and empathic understanding for both types of visual rhetoric. Breaking down it by type of rhetoric, no interacting effect was observed between brand sensitivity and empathic understanding levels for the visual simile ads in most of the dependent variables. For the visual metaphor ads, however, the brand sensitivity and empathic understanding levels were found to have interaction effect in all dependent variables.

Landscape Information Visualization of Landscape Potential Index in Hilly Openspace Conservation of Urban Fringe Area (도시주변 녹지경관의 보전.관리에 있어 경관잠재력 지표의 경관정보화와 가시화 연구)

  • Cho, Tong-Buhm
    • Journal of Korean Society of Rural Planning
    • /
    • v.7 no.1 s.13
    • /
    • pp.37-48
    • /
    • 2001
  • The purpose of this study is to suggest the landscape potential index for visualizing landscape information in the conservation of hilly landscape in urban fringe. For the visual and quantitative approach to topological landscape assessment, numerical entity data of DEM(digital elevation model) were processed with CAD-based utilities that we developed and were mainly focused on analysis of visibility and visual sensitivity. Some results, with reference in assessing greenbelt area of Eodeung Mt. in Gwangju, proved to be considerable in the landscape assessment of suburban hilly landscapes. 1) Since the viewpoints and viewpoint fields were critical to landscape structure, randomized 194 points(spatially 500m interval) were applied to assessing the generalized visual sensitivity, we called. Because there were similar patterns of distribution comparing to those by 56 points and 18 Points given appropriately, it could be more efficient by a few viewpoints which located widely. 2) Regressional function was derived to represent the relationships between probabilities of visibility frequency and the topological factors(topological dominance, landform complexity and relational aspect) of target field. 3) Visibility scores of each viewpoint were be calculated by summing the visual sensitivity indices within a scene. The scores to the upper part including ridge line have been more representative to overall distributions of visual sensitivities. Also, with sum of deviations of sensitivity indices from each single point's specific index to the weighting values of view points could be estimated rotationally. 4) The deviational distributions of visual sensitivity classes in the topological unit of target field were proved to represent the visual vulnerability of the landform. 5) Landscape potential indices combined with the visual sensitivity and the DGN(degree of green naturality) were proposed as visualized landscape information distributed by topological unit.

  • PDF

Development of a CAD Based Tool for the Analysis of Landscape Visibility and Sensitivity (수치지형 해석에 의한 가시성 및 시인성의 경관정보화 연구 - CAD 기반의 분석 도구 개발을 중심으로 -)

  • 조동범
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.78-78
    • /
    • 1998
  • The purpose of this research is to develop a CAD-based program for data analysis of digital elevation model(DEM) on the aspect of landscape assessment. When handling DEM data as a visual simulation of topographic landscape, it is basic interest to analyze visible area and visualize visual sensitivity distributions. In reference with landscape assessment, more intuitive and interactive visualizing tools are needed, specially in area of visual approach. For adaptability to landscape assessment, algorithmic approaches to visibility analysis and concepts for visual sensitivity calculation in this study were based on processing techniques of entity data control functions used in AutoCAD drawing database. Also, for the purpose of quantitative analysis, grid-type 3DFACE entities were adopted as mesh unit of DEM structure. Developed programs are composed of main part named VSI written in AutoLISP and two of interface modules written in dialog control language(DCL0 for user-oriented interactive usage. Definitions of camera points(view points) and target points(or observed area) are available alternatively in combined methods of representing scenic landscape, scenery, and sequential landscape. In the case of scene landscape(single camera to fixed target point), only visibility analysis in available. And total visibility, frequency of cumulative visibility, and visual sensitivity analysis are available in other cases. Visual sensitivity was thought as view angle(3 dimensional observed visual area) and the strengths were classified in user defined level referring to statistical characteristics of distribution. Visibility analysis routine of the VSI was proved to be more effective in the accuracy and time comparing with similar modules of existing AutoCAD third utility.

Evaluation of Visual Sensitivity according to Basic Figure and Color -Focused on the College Students of Daejeon and Daegu- (기초도형과 색에 따른 시각감성 평가 - 대전과 대구지역의 대학생을 중심으로 -)

  • Kim, Myo-Hyang;Yun, Chong-Hee
    • Fashion & Textile Research Journal
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2004
  • We evaluate what kinds of differences are existed to the visual sensitivity of college students m Daegu and Daejeon. Evaluation used the produced basic pattern to change modeling element of figure, direction, proportion, and color. The results are as below. The circle is preferred to the figure sensitivity and the triangle in Daegu and triangle and quadrangle in Daejeon is disliked. The direction sensitivity shows the difference of preferences according to figure. The angle of $0^{\circ}$ and $90^{\circ}$ which could be felt stability is preferred in general. In proportion sensitivity, the basic figure 1:1 rectangular proportions are preferred. The color sensitivity I shows the differences of preference according to figure and there are difference to the area in the degree of aversion.

Prediction of visual performance using contrast sensitivity function and modulation transfer function (대비감도함수와 변조전달함수를 이용한 시기능 예측)

  • Kim Sang Gee;Park Sung Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.461-468
    • /
    • 2004
  • A finite model eye of visual acuity 24/20 in emmertropia was presented. We determined the image intensity profile on retina using optical transfer function of model eye, and compared with clinical data. The retinal contrast sensitivity function based on the Stiles-Crawford effect, photopic response, diffraction, aberration, retinal contrast sensitivity, and pupil size is calculated. Visual acuity for human eye could be predicted by examining the modulation transfer function of a bar target and retinal contrast sensitivity function. This visual acuity was evaluated for pupil diameters ranging from 1 to 8 mm.

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

Effect of red ginseng on visual function and vision-related quality of life in patients with glaucoma

  • Lee, Kwanghyun;Yang, Heon;Kim, Joo Yeon;Choi, Wungrak;Seong, Gong Je;Kim, Chan Yun;Lee, Jun Mo;Bae, Hyoung Won
    • Journal of Ginseng Research
    • /
    • v.45 no.6
    • /
    • pp.676-682
    • /
    • 2021
  • Background: Red ginseng has been found to improve ocular perfusion and dry eye syndrome in glaucomatous eyes; however, its effects on visual function and vision-related quality of life have not been investigated. This study sought to evaluate the effects of red ginseng on visual function and vision-related quality of life in glaucoma patients using contrast sensitivity and a questionnaire. Methods: Participants were randomly assigned to two groups in this prospective, randomized, double-blind study: in one group, red ginseng was taken first, followed by a placebo, and in the other, placebo was taken first, followed by red ginseng. We measured and compared changes in contrast sensitivity and vision-related quality of life between the two groups. Contrast sensitivity was measured using OPTEC® 6500P, and vision-related quality of life was evaluated using the 25-item National Eye Institute Visual Function Questionnaire. One-way and two-way repeated measure analyses of variance were used for the comparison. Relationships between respective changes in dry eye syndrome and contrast sensitivity were also analyzed. Results: Daytime contrast sensitivity and ocular pain improved after the administration of red ginseng. Nighttime contrast sensitivity was improved in early or moderate glaucoma. Improved contrast sensitivity was not associated with improvement in dry eye syndrome. Conclusion: Red ginseng could improve contrast sensitivity and ocular pain in patients with glaucoma. The mechanism underlying improvement in contrast sensitivity appears to be associated with enhanced retinal perfusion or retinal ganglion cell function, but not dry eye syndrome.