• 제목/요약/키워드: Virtual Milling

검색결과 22건 처리시간 0.024초

Insert Tip용 End Mill 공구의 형상정의와 5-축 가공에 관한 연구 (A Study on Geometric Definition and 5-Axis Machining of End Mill with Insert Tip)

  • 조현덕;박영원
    • 한국공작기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.1-9
    • /
    • 2002
  • This study describes the geometric characteristics and the 5-axis machining method in order to make end mill cutter coming with insert tips. End mill geometry is consisted of flute part and insert tip part. Flute part modeled by using ruled surfaces with constant helix angle, and insert tip part modeled by rectangular planes containing tapped hole of specified direction in its center. In this study, the modeled insert tip part considered both of a radial rake angle and a axial rake angle, because they were important cutting conditions. In order to machining the virtual end mill defined from geometric characteristics, we programmed a special software to machining the end mill considered in this study. This software can generate NC-codes about following processes, end milling or ball end milling of flute part end milling of rectangular plane, centering of hole, drilling of hole, and tapping of hole. Ant sampled end mills were modeled and machined on 5-axis CNC machining center with two index tables. Since machined end mills were very agreeable to designed end mills, we saw that the method proposed in this study can be very useful for manufacturing of end mill body with insert tip.

Modeling the Density and Hardness of AA2024-SiC Nanocomposites

  • Jeon, A-Hyun;Kim, Hong In;Sung, Hyokyung;Reddy, N.S.
    • 한국분말재료학회지
    • /
    • 제26권4호
    • /
    • pp.275-281
    • /
    • 2019
  • An artificial neural network (ANN) model is developed for the analysis and simulation of correlation between flake powder metallurgy parameters and properties of AA2024-SiC nanocomposites. The input parameters of the model are AA 2024 matrix size, ball milling time, and weight percentage of SiC nanoparticles and the output parameters are density and hardness. The model can predict the density and hardness of the unseen test data with a correlation of 0.986 beyond the experimental data. A user interface is designed to predict properties at new instances. We have used the model to simulate the individual as well as the combined influence of parameters on the properties. Moreover, we have analyzed the calculated results from the powder metallurgical point of view. The developed model can be used as a guide for further composite development.

가상 측정을 통한 펜슬곡선 추출 (Pencil Curve Tracing via Virtual Digitizing)

  • 박정환;김보현;최병규
    • 한국CDE학회논문집
    • /
    • 제2권4호
    • /
    • pp.253-266
    • /
    • 1997
  • Pencil-curve machining, which is a single-pass ball-end milling along a concave edge on adie surface, is widely employed in die-surface machining. The cutter-path used for pencil-curve machining, which is the trajectory of the “ball-center point” of a ball-endmill sliding along a concave-edge region on the die surface, is called pencil-curve. Presented in the paper is a pencil-curve tracing algorithm in which “concave-type” sharp edges are computed from a “virtually digitized” model of the tool-envelope surface. The resulting “initial” pencil-cures are then refuted by applying a series of fairing operations. illustrative examples and methods for enhancing accuracy are also presented. The proposed pencil-curve tracing algorithm has been successfully implemented in a commercial CAM system specialized in die-machining and in the CAD/CAM system CATIA.

  • PDF

6축 병렬기구 공작기계의 머신 시뮬레이션과 앵글밀링헤드 적용에 관한 연구 (A Study on the Application of Machine Simulation and Angle Milling Head of a 6-Axis Parallel Kinematic Machine)

  • 이인수;김해지;김남경
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.47-54
    • /
    • 2017
  • This study examines the implementation of a kinematic machining tool to evaluate the interference and collision phenomenon of 5-axis machining of wing ribs from airplanes, particularly for a large-size model airplane. We develop a machine simulation model of a parallel kinematic machining tool that can operate in a virtual space, which is equivalent to the authentic conditions in the field. The investigation of the simulation function elements indicates the necessity to generate the 6-axis machining, which attaches an angle head to the main axis of the machine. Using an NC program for the wing ribs, we attempt to verify the correspondence and conformity between the machine simulation model and the actual equipment.

Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation

  • Hassan, Bassam;Greven, Marcus;Wismeijer, Daniel
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.381-386
    • /
    • 2017
  • PURPOSE. To integrate extra-oral facial scanning information with CAD/CAM complete dentures to immediately rehabilitate terminal dentition. MATERIALS AND METHODS. Ten patients with terminal dentition scheduled for total extraction and immediate denture placement were recruited for this study. The patients were submitted to a facial scanning procedure using the in-office PritiMirror scanner with bite registration records in-situ. Definitive stone cast models and bite records were subsequently submitted to a lab scanning procedure using the lab scanner (iSeries DWOS; Dental Wings). The scanned models were used to create a virtual teeth setup of a complete denture. Using the intra-oral bite records as a reference, the virtual setup was incorporated in the facial scan thereby facilitating a virtual clinical evaluation (teeth try-in) phase. After applying necessary adjustments, the virtual setup was submitted to a CAM procedure where a 5-axis industrial milling machine (M7 CNC; Darton AG General) was used to fabricate a full-milled PMMA immediate provisional prosthesis. RESULTS. Total extractions were performed, the dentures were immediately inserted, and subjective clinical fit was evaluated. The immediate provisional prostheses were inserted and clinical fit, occlusion/articulation, and esthetics were subjectively assessed; the results were deemed satisfactory. All provisional prostheses remained three months in function with no notable technical complications. CONCLUSION. Ten patients with terminal dentition were treated using a complete digital approach to fabricate complete dentures using CAD/CAM technology. The proposed technique has the potential to accelerate the rehabilitation procedure starting from immediate denture to final implant-supported prosthesis leading to more predictable functional and aesthetics outcomes.

마스터/슬레이브 복합형 고관절 전치환 수술로봇의 제어 (Control of a Master/Slave Combined Surgical Robot for Total Hip Arthroplasty)

  • 허관회;권동수;김상연;이정주;윤용산
    • 제어로봇시스템학회논문지
    • /
    • 제8권9호
    • /
    • pp.788-794
    • /
    • 2002
  • To improve surgical result of total hip arthroplasty (THA), there has been some approaches using a robotic milling system, which can make a precise cavity in the femur. Usually, to carve a femur, the surgical robot is controlled by a pre-programmed tool-path regardless of a surgeon's experience and Judgment. This paper presents a control method of a surgical robot for THA, which can be used as an advanced surgical tool. With a master/slave combined surgical robot, surgeon can directly control the motion and velocity of a surgical robot. The master/slave-combined robot is controlled to display a specific admittance for a surgeon's force to the surgical robot velocity. To prevent the over-carving of a femur, virtual hard wall is displayed on the surgical boundary. To evaluate the proposed control method of the master/slave-combined surgical robot, 2-DOF master/slave-combined manipulator is used in experiment.

Design of a Hybrid Serial-Parallel Robot for Multi-Tasking Machining Processes (ICCAS 2005)

  • Kyung, Jin-Ho;Han, Hyung-Suk;Ha, Young-Ho;Chung, Gwang-Jo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.621-625
    • /
    • 2005
  • This paper presents a new hybrid serial-parallel robot(HSPR), which has six degrees of freedom driven by ball screw linear actuators and motored joints. This hybrid robot design presents a compromise between high rigidity of fully parallel manipulators and extended workspace of serial manipulators. The hybrid robot has a large, singularity-free workspace and high stiffness. Therefore, the presented kinematic structure of the hybrid robot is particularly suitable for multi-tasking machining processes such as milling, drilling, deburring and grinding. In addition to the machining processes, the hybrid robot can be used for welding, fixturing, material handling and so on. The study on design of the hybrid robot is performed. A kinematic analysis and mechanism description of the hybrid robot with six-controlled degree of freedom is presented. In the virtual design works by DADS, workspace and force analysis are discussed. A numerical model is treated to demonstrate our analysis and to determine the range of permissible extension of the struts. Also, we determine some important design parameters for the hybrid robot.

  • PDF

가상환자 데이터세트를 기반으로 악관절과 심미를 고려한 진단 및 치료계획 수립 (From TMJ to 3D Digital Smile Design with Virtual Patient Dataset for diagnosis and treatment planning)

  • 이수영;강동휘;이도연;김희철
    • 대한심미치과학회지
    • /
    • 제30권2호
    • /
    • pp.71-90
    • /
    • 2021
  • 가상 환자 데이터 세트는 단일 환자로부터 획득한 구강스캔 안면스캔 전신스캔 하악운동경로데이터 등 다양한 소스의 진단 데이터를 하나의 3차원 좌표계로 정렬한 데이터의 집합이다. 치과의사는 가상 환자 데이터 세트를 사용하여 효과적으로 치료 계획을 수립하고 다양한 치료 계획을 가상공간상에서 시뮬레이션 할 수 있으며, 가상 환자 데이터 세트에서 환자의 미소를 디자인 후 그 결과를 시뮬레이션하고 최적의 치료결과를 선택할 수 있다. 가상공간에서 선택된 치료 계획은 3D 프린팅, 밀링, 사출 성형과 같은 제조 기술을 사용하여 환자에게 동일하게 전달될 수 있다. 이러 치료 계획의 전달은 임시 수복물 제작 및 환자의 구강 내에서 목업 확인을 통해 최종 보철물 제작으로 연결할 수 있다. 이와 같이 진단 데이터, 중첩 및 가공의 정확도가 보장된다면 3차원 가상공간 상에서 시뮬레이션된 3D 디지털 스마일 디자인을 실제 환자에게 정확하게 전달할 수 있다. 가상환자데이터세트의 임상적용방법으로 동기능적교합측정 검사를 통해 교합조정치료를 치료계획에서 배제할수 있는 의사결정방법과, 턱관절질환을 가지고 있는 청소년기 특발성 척추측만증 환자의 턱관절 치료전후 전신스캔 비교분석방법, 그리고 전악수복증례인 상하악 총의치환자 진료시 가상환자데이터세트에 기반한 교합평면분석 및 디지털심미분석방법을 제시하였다.

가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구 (Accuracy of 5-axis precision milling for guided surgical template)

  • 박지만;이태경;정제교;김용;박은진;한종현;곽재영;김성균;허성주
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.294-300
    • /
    • 2010
  • 연구 목적: 컴퓨터-가이드 임플란트 수술은 전통적인 방법에 비해 여러 가지 장점을 가진다. 본 연구의 목적은 가이드 수술용 템플릿 제작을 위한 좌표동기화 5축 정밀가 공공정의 정확도를 범용 CAD 소프트웨어를 통해 역설계공학의 방법으로 평가하는 것이다. 연구 재료 및 방법: 악궁 형태의 모형에 거타퍼쳐 스타핑을 매식한 10 개의 모형을 만들고 상부에 실리콘 인상재를 이용하여 인공치은을 덮어 스타핑의 위치를 보이지 않게 가렸다. 모형의 하면에 동기화를 위한 좌표동기화 형상을 만든 뒤 Cone beam CT에서 3차원 영상을 얻었다. 임플란트 계획 소프트웨어의 CT 이미지 상에서 매식된 스타핑과 동일한 방향으로 스타핑의 1/2 깊이까지 가상의 시술계획을 하고, 스타핑의 방향벡터와 저지점 (1/2지점) 데이터를 석고모형의 영상으로 좌표동기화 하였다. 이후 모형하면의 좌표동기화 형상을 이용하여 가공기기상의 좌표로 좌표변환을 통해 가공좌표동기화를 하였다. 5축 밀링머신의 좌표동기화판에 모형을 고정한 후, 동기화된 가공데이터에 의거하여 스타핑과 동일한 직경의 드릴로 계획된 벡터와 깊이로 정확히 가공 하였다. 모델에 정확히 안착되는 인상트레이를 CT 장비에 미리 고정한 상태에서, 인상트레이에 모델을 적합하여 이미지를 획득한 뒤 3차원 재구성하는 방법으로 영상을 중첩하여 비교 분석하였다. SolidWorks (Dassault Systems, Concord, USA) 범용 CAD 상에 영상을 불러들여 역설계공학의 방법으로 실린더 상부, 하부의 중점에서의 위치편차와 각도편차를 조사하였다. 통계는 SPSS (release 14.0, SPSS Inc., Chicago, USA)를 이용하여 각 편차 사이의 상관관계를 분석하였다 ($\alpha$ = 0.05). 결과: 위치 편차로 인하여 모든 드릴 보어 (bore)에서 상부 1/2에 잔존하는 거타퍼쳐의 일부를 관찰할 수 있었다. 실험 모형상에서 계획된 이미지와 드릴링 후CT에서 역설계를 거친 이미지 사이의 위치편차는 상부에서 0.31 (0.15 - 0.42) mm, 하부에서 0.36 (0.24 - 0.51) mm, 각도편차는 1.62 (0.54 - 2.27)$^{\circ}$이었다. 실린더 상부와 하부 위치 편차는 양의 상관관계를 가졌다 (Pearson Correlation Coeffocient = 0.904, P= .013). 결론: 좌표동기화 5축 정밀가공 공정은 가이드 수술용 템플릿을 제작하는 데에 적합한 정확도를 가진다.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).