• Title/Summary/Keyword: Vinyl chloride monomer

Search Result 18, Processing Time 0.02 seconds

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

Introduction of vinyl Compounds Containing Hydroxyl Group into Polyamide Reverse Osmosis Membrane

  • 염민오;김학상;김성수;김재진
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.54-55
    • /
    • 1995
  • 현재 수처리용 분리막으로 널리 사용되고 있는 상업용 polyamide membrane은 주사슬을 이루고 있는 amide bond가 chlorine에 쉽게 분해됨으로써 주쇄의 절단이 일어나므로 막이 파괴되는 결과를 초래하여 역삼투 분리막의 기능이 저하되는 문제점을 갖고 있다. 또한 분리막의 성능으로써 수투과도의 향상도 기존의 분리막의 개선점으로 지적되고 있다. 본 연구에서는 재료 자체의 친수성이 강한 hydroxyl group을 가진 vinyl계 화합물을 기존의 amine계 monomer와 혼합하여 가교반응을 시킴으로써 전체적인 분리막의 수투과도 및 내염소성의 향상을 도모하였다. 기존의 polyamide 분리막의 소재인 1,3-phenylenediamine(MPDA)에 친수성기인 hydroxyethylmethacrylate(HEMA) monomer를 첨가하고 가교제인 trymesoyl chloride(TMC)로 이를 가교시켜 HEMA 및 PVA의 친수성에 의한 수투과도 및 내염소성의 향상을 유도하여 보았다.

  • PDF

Making the Difference in Occupational Health: Three Original and Significant Cases Presented at ICOH Congresses in the 20th Century

  • Iavicoli, Sergio;Valenti, Antonio;Barillari, Caterina;Fortuna, Grazia;Boccuni, Valeria;Carnevale, Francesco;Riva, Michele A.;Kang, Seong-Kyu;Tomassini, Luigi
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.215-221
    • /
    • 2020
  • Background: The aim of this study is to illustrate the historical role of the International Commission on Occupational Health (ICOH) congresses as an arena where national and international occupational medicine can dialogue and as the first example of scientific transferability of the research and prevention results that have had such an impact on global public health. Methods: We used the ICOH Heritage Repository, in which ICOH congress proceedings (from the first congress in Milan in 1906 to the last congress, held in Dublin in 2018), are organised in an orderly way, updated and easily accessible according to open access logic. Results: We describe studies by three physicians who submitted significant scientific work to ICOH congresses, one on the battle against ancylostomiasis (Volante, 1906), the second (Quarelli, 1928) on carbon disulphide poisoning, and the third (Viola, 1969) on the carcinogenicity of vinyl chloride monomer. Priority is given to Italian cases, on account of the authors' obvious familiarity with the issues. Conclusion: The visibility offered in ICOH conferences and their published proceedings has boosted the international spread of their findings, contributing to the scientific transferability of the research results and influencing the development of policies and prevention interventions that have had a great impact on global public health.

Preparation and Characterization of Proton Conducting Crosslinked Membranes Based On Poly(vinyl chloride) Graft Copolymer (Poly(vinyl chloride) 가지형 공중합체를 이용한 수소이온 전도성 가교형 전해질막의 제조와 분석)

  • Kim, Jong-Hak;Koh, Jong-Kwan;Choi, Jin-Kyu;Park, Jung-Tae;Koh, Joo-Hwan
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.261-267
    • /
    • 2008
  • A graft copolymer consisting of poly(vinyl chloride) (PVC) backbone and poly(hydroxyethyl acrylate) (PHEA) side chains was synthesized via atom transfer radical polymerization (ATRP). Direct initiation of the secondary chlorines of PVC facilitates grafting of hydrophilic PHEA monomer. This graft copolymer, i.e. PVC-g-PHEA was cross-linked with sulfosuccinic acid (SA) via the esterification reaction between -OH of the graft copolymer and -COOH of SA, as confirmed by FT-IR spectroscopy. Ion exchange capacity (IEC) continuously increased to 0.87meq/g with increasing concentrations of SA, due to the increasing portion of charged groups in the membrane. However, the water uptake increased up to 20.0wt% of SA concentration above which it decreased monotonically. The membrane also exhibited a maximum proton conductivity of 0.025 S/cm at 20.0 wt% of SA concentration, which is presumably due to competitive effect between the increase of ionic sites and the crosslinking reaction.

Raman Spectroscopy of Irradiated Normoxic Polymethacrylic Acid Gel Dosimeter

  • Bong, Ji-Hye;Choi, Kyu-Seok;Yu, Soo-Chang;Kwon, Soo-Il;Cho, Yu-Ra;Park, Chae-Hee;Park, Hyung-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.625-629
    • /
    • 2011
  • A quantitative analysis of the decreasing rate of the monomer and increasing rate of the polymerization was made by monitoring radiation level increments using Raman spectroscopy within the therapeutic radiation range for a normoxic polymethacrylic acid gel dosimeter. The gel dosimeter was synthesized by stirring materials such as gelatin, distilled water, methacrylic acid, hydroquinone and tetrakis phosphonium chloride at $50^{\circ}C$, and the synthesized gel was contained in a 10- mm diameter and 32-mm high vial to conduct measurement. 24 hours after gel synthesis, it was irradiated from 0 Gy to 20 Gy by 2 Gy using a Co-60 radiotherapy unit. With use of the Cryo FE-SEM, structural changes in the 0 Gy and 10 Gy gel dosimeters were investigated. The Raman spectra were acquired using 532-nm laser as the excitation source. In accordance with fitting the changes in C-COOH stretching (801 $cm^{-1}$), C=C stretching (1639 $cm^{-1}$) and vinyl $CH_2$ stretching (3114 $cm^{-1}$) vibrational modes for monomer and $CH_2$ bending vibrational mode (1451 $cm^{-1}$) for polymer, sensitive parameter S for each mode was calculated. The values of S for monomer bands and polymer band were ranged in $6.0{\pm}2.6$ Gy and $7.2{\pm}2.3$ Gy, respectively, which shows a relatively good conformity of the decreasing rate of monomer and the increasing rate of polymerization within the range of error.

A Study on the Control and Exposure Assessment to Vinyl Chloride in the Factory Processing and Producing PVC Resin (일부 PVC 수지 제조 및 가공 근로자의 염화비닐 폭로 평가와 대책에 관한 조사 연구)

  • Park, D.W.;Shin, Y.C.;Lee, N.R.;Lee, K.Y.;Oh, S.M.;Chung, H.K.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • This study was carried out to assess worker exposure to vinyl chloride monomer (VCM) and to present control measures in the factories processing and producing polyvinyl chloride (PVC) resin. The conclusion remarks are as follows. Only two personal samples in the factory ("E") processing polyvinyl chloride resin were analysed to be 27.6 ppm and 12.6 ppm, respectively. But, these concentration exceed 1 ppm, Permissible Exposure Limits (PEL) of OSHA. So, worker's exposure to VCM at "E" factory should be reevaluated. In "A", "B" and "C" factory producing polyvinyl chloride resin, the average worker's exposures to VCM were 0.12 ppm, 0.86 ppm and 1.23 ppm, respectivery. Worker exposure to VCM at distillation and dry process was higer than other processes at "A" factory. The average exposure concentration of worker at polymerization process of "B" and "C" factory was 1.23 ppm, and 1.46 ppm respcetively. These concentration exceed 1 ppm, Permissible Exposure Limits of OSHA. Control room of "B" and "C" factory had 0.91 ppm and 0.65 ppm of worker's exposure concentration respectively. "A" factory was evaluated to be "acceptable", but "B" and "C" factories were evaluated to be "not acceptable", by the workplace exposure assessment program of AIHA. Process other than bagging and control room of "A" factory was evaluated to "not acceptable". Immediate correction measures for preventing workers from exposure to VCM should be performed in the factories or process that were evaluated to be "not acceptable". After these control measures are taken, worker exposure to VCM must be reevaluated through personal air monitoring. Control measures presented by this study are complete sealing of connecting pipe lines, flanging, packing, bolting and nutting. Periodic leak test for leak parts is also required. And positive pressure facility should be constructed at control room of "B" and "C" factory. Fresh air through cleaner such as HEPA filter should be supplied to control room. In addition to these control measures, periodic personal monitoring for evaluating worker exposure to VCM should be performed.

  • PDF

Polymerization of Vinyl Monomers Initiated by Cobalt (II) Chloride (염화코발트(Ⅱ)에 의한 비닐단위체의 중합)

  • Lee Dong-ho;Ahn Tae-oan
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.53-64
    • /
    • 1975
  • The polymerization of methyl methacrylate initiated by cobalt(II) chloride in tetrahydrofuran has been studied. The conversion was increased liearly with polymerization time at initial stage of 6${\sim}$7% conversion and then the rate of polymerization was slightly reduced, and after that the autoacceleration was observed. The rate of polymerization was increased with the concentration of cobalt(Ⅱ) chloride, but at the concentration of cobalt(II) chloride higher than $3.4{\times}10^{-4}$ mole/l the rate of polymerization was decreased. The rate of polymerization was dependent on the 1.38 power of the concentration of methyl methacrylate. The effect of the radical inhibitor DPPH was observed and the inhibition time was increased with the concentration of DPPH. The apparent overall activation energy was calculated to be 13.2 kcal/mole. In the copolymerization of methyl methacrylate ($M_1$) and styrene ($M_2$), the monomer reactivity ratio was found to be $r_1$ = 2.35, $r_2$ = 0.78. From the above results. the initiation mechanism of polymerization was discussed and it was considered that the polymerization proceeds mainly via diradical mechaism.

  • PDF

The Effect of Temperature on the Breakthrough of Charcoal Tube During Vinyl Chloride Monomer Sampling (공기중 염화비닐단량체 포집시 온도가 파과현상에 미치는 영향)

  • Park, Youn Jung;Lee, Sang Hoi;Kim, Chi Nyon;Won, Jong Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.115-123
    • /
    • 1998
  • Vinyl chloride monomer exists as gas phase at normal temperature and reacts with oxygen and strong oxidant in the air to form oxidized materials. Because of being easily synthesized, it is used as a main source at the synthetic reaction process of PVC synthesis factories. Ministry of Labor regulates its usage as a carcinogen and its exposure level as 1 ppm. But the amount of VCM production in PVC and VCM production process hasn't been exactly estimated. In addition, facilities of this factory are located in outdoor. Therefore, this study was designed to investigate effects of temperature on breakthrough of charcoal tube at a fixed concentration and temperature during VCM sampling based on NIOSH and OSHA methods which were used as methods of occupational environment measuring and analysis. During the sampling of VCM, methods of OSHA and NIOSH require flow rate of 0.05 lpm and sampling volume of $3{\ell}$, $5{\ell}$ respectively, at this time carbon molecular sieve tube and coconut shell charcoal tube are used to observe the breakthrough along with concentration and temperature. As a result, significant difference between average adsorbed amounts of OSHA methods but that of NIOSH methods cannot be found. NIOSH method is likely to be effected by high temperature and normal temperature in high concentration. Breakthrough is not found in the method of OSHA at different conditions of temperature and concentration. As the result of this study we could verify that breakthrough occurred in the process of sampling VCM with NIOSH methods. Therefor in summer time, breakthrough should be considered and research on the breakthrough volume should be done. It is considered the research about the specificity of the coconut shell charcoal and carbon molecular sieve sorbent should be done when sampling VCM in comming days.

  • PDF