• 제목/요약/키워드: ViewRay

검색결과 380건 처리시간 0.023초

슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가 (Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint)

  • 김현진;주영철;최재호;임우택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가 (The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View)

  • 고예원;주영철;김민석;고유림
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

Ray-Tracing 알고리즘을 이용한 CCTV배치 평가시뮬레이션 (Simulation to Evaluate CCTV Positioning in Use of Ray-Tracing Algorithm)

  • 김석태;안상욱
    • 한국실내디자인학회논문집
    • /
    • 제22권6호
    • /
    • pp.40-48
    • /
    • 2013
  • Utilization of CCTV in crime prevention for public safety is accepted as the most effective measure in terms of crime prevention and control. Also, it is frequently used as a device that shows evidence of an unexpected situation or record on public social relationship. However, it is rare to find a study that qualitatively accessed the monitoring performance of a certain space depending on the choice and positioning of CCTVs. Thus, this study suggested a technology that can quantitatively compare and assess the monitoring performance of CCTVs depending on view angle and effective sight range of cameras as well as the monitoring performance depending on positioning measures. For the analysis, the concept of 3-dimensional surveillance field in the form of a frustum was suggested while deriving 3-dimensional range of sight and quantitative monitoring performance by applying Isovist theory. For the analysis technology, space of analysis subject, point of view (camera), and target point (measurement node) were installed at a 3-dimensional space and in use of ray-tracing algorithm, the line segment that was visually connected between the point of view and target point was extracted and accumulated. For such verification, analysis application was constructed and then applied to four alternative models on view angle and distance as well as four alternatives on positioning in order to verify its efficacy. Through the experiment, it was possible to compare and assess visibility depending on alternatives while quantifying the results by understanding the shadow areas beyond the monitoring range.

Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법 (An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교 (Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs))

  • 길종원;이광성
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.605-611
    • /
    • 2019
  • 본 연구의 목적은 여러 가지 하지입식검사에 적용할 수 있는 Multi-Function Device(MFD)를 제작하여 기존에 사용하던 Weight Bearing Platforms(WBPs)들과 X 선 영상의 비교를 통해 임상 활용을 제안하고자 한다. MFD는 단상(보조기구)를 이용한 Weight Bearing Foot/Ankle, Hindfoot Alignment View 검사시 X선 장치의 X선 관구의 최하 조절 높이를 고려하여 제작하였다. 그리고 Foot/Ankle Phantom으로 MFD와 WBPs에서 Weight Bearing Lateral Foot과 Hindfoot Alignment View를 검사하여 X선 영상의 해상력을 Quick MTF(modulation transfer function)프로그램으로 비교하였다. 연구결과 MFD와 WBPs에서 검사한 두 가지 영상 모두 MTF 50(50% Contrast Spatial Frequency)과 10-90%(10-90% of Maximum Energy Rise Distance) Rise의 C/P(Cycles Per Pixel)평균과 LPH(Lines Per Image Height)평균 모두 유의한 차이는 없었다(p>0.05). 연구에서 제작한 MFD는 환자의 안전과 여러 가지 검사를 복합적으로 수행 할 수 있는 유용한 보조기구로 임상 활용을 제안한다. 또한 정책적으로 보조기구의 활용을 권장한다면 전문 업체의 활성화를 돕는 길이며 의료의 질도 더욱 향상할 수 있을 것이다.

그림자 계산을 이용한 운전자의 시계성 해석 (Analysis of Driver's Field of View using a Shadow Algorithm)

  • 김재정;하용수;김용철
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.123-131
    • /
    • 1997
  • To ensure drive's field of view, obstruction area generated by a steering wheel, hub and spoke must be considered at the early stage of automobile design. The current approach to computing obstruction area proposed by SAE is based on 2D drafting procedures so that it is not precise and errorprone. In the paper we discuss the novel approach which models the obstruction area as the shadows of the steering wheel, hub and spoke by assuming the human eye as light sources. The approach is based on ray tracing and space transformations for that it can be applied when free form curves are hired to represent the steering wheel, hub and spoke in CAD environment. As a result, it gives more predise and reliable results than SAE approach.

  • PDF

광선의 차폐가 없는 광시야 비축 2반사광학계 설계 (Optical Design of a Wide-field Off-axis Two-mirror System without Ray Obstruction)

  • 오혜진;이종웅
    • 한국광학회지
    • /
    • 제28권6호
    • /
    • pp.263-272
    • /
    • 2017
  • 넓은 시야를 가지는 광학계에서는 전반부는 음의 굴절능, 후반부는 양의 굴절능을 가지는 inverted telephoto 구조가 일반적으로 사용되고 있고, 2반사광학계에서는 inverse Cassegrain system이 inverted telephoto 구조에 해당한다. 하지만 통상적인 회전대칭 구성의 inverse Cassegrain system에서는 시야가 가려지고 광선의 차폐가 심한 문제점이 있다. 이 연구에서는 이점을 고려하여 inverse Cassegrain system의 제2면에 조리개를 두어 시야를 넓히고, 광선의 차폐가 없는 비축시야만을 사용하는 광시야 비축 2반사광학계를 설계하였다.

On the Optical Characteristics of Solar X-Ray Telescopes: Possible Relation between Vignetting Effect and Mirror Scattering

  • Shin, Jun-Ho;Sakurai, Takashi
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • Since early 90's, the solar X-ray telescopes such as Yohkoh SXT and Hinode XRT have observed coronal magnetic structures on the Sun's surface in the range of about $40'{\times}40'$ field-of-view (FOV) covering the full solar disk. Thus it has been stressed by the scientists that the optical structure of solar telescopes should be designed with care for improving the uniformity over a wide FOV. There would be, however, no unique solution in designing the optical system of a telescope for overcoming perfectly the problem of off-axis response variation. As a consequence, the correction of optical imperfectness of telescopes has become an important calibration step that should be performed beforehand when the observed images are to be used for photometric purposes. In particular, a special care should be taken when performing the temperature analysis with thin and thick filters for flaring activities observed at the periphery of the full FOV. From the analyses of both pre-launch calibration and in-flight observation data, the optical characteristics for describing the performance of solar X-ray telescopes, especially in view of their energy dependence, will be introduced and discussed in our presentation.

  • PDF