• 제목/요약/키워드: ViewRay

검색결과 382건 처리시간 0.026초

WALK-THROUGH VIEW FOR FTV WITH CIRCULAR CAMERA SETUP

  • Uemori, Takeshi;Yendo, Tomohiro;Tanimoto, Masayuki;Fujii, Toshiaki
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.727-731
    • /
    • 2009
  • In this paper, we propose a method to generate a free viewpoint image using multi-viewpoint images which are taken by cameras arranged circularly. In past times, we have proposed the method to generate a free viewpoint image based on Ray-Space method. However, with that method, we can not generate a walk-through view seen from a virtual viewpoint among objects. The method we propose in this paper realizes the generation of such view. Our method gets information of the positions of objects using shape from silhouette method at first, and selects appropriate cameras which acquired rays needed for generating a virtual image. A free viewpoint image can be generated by collecting rays which pass over the focal point of a virtual camera. However, when the requested ray is not available, it is necessary to interpolate it from neighboring rays. Therefore, we estimate the depth of the objects from a virtual camera and interpolate ray information to generate the image. In the experiments with the virtual sequences which were captured at every 6 degrees, we set the virtual camera at user's choice and generated the image from that viewpoint successfully.

  • PDF

Supine Position에서 Modified Y-View의 제안 (Suggestion of Modified Y-View in Supine Position)

  • 신성규;백성민;이효영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.103-107
    • /
    • 2012
  • 본 연구는 어깨 통증을 호소하는 환자들 중 어깨충돌 증후군(SIS : Shoulder Impingement Syndrome)이 의심되어 진단을 위해 Y-view 검사가 필요하지만 몸이 불편하여 자세를 취하기 힘든 환자들을 위하여 편안하게 누운 자세에서 검사할 수 있는 modified Y-View를 고안하기 위해 연구를 실시하였다. 환자는 바로 누운 자세를 취하고 X선관(tube)의 각도를 내측으로 35도, 40도, 45도로 변화를 주어 검사한 영상을 비교 분석해 본 결과 X선관(tube)의 각도를 내측방향으로 40도를 주는 것이 견봉(acromion)과 쇄골(clavicle)의 공간(space), 오훼견봉궁(coracoacromial arch)의 모양을 잘 묘출 할 수 있어 진단에 가장 유용한 영상을 얻을 수 있었다. 따라서 환자가 Y-View 검사를 할 수 없을 경우, 이를 대체하기 위한 유용한 수단으로 modified Y-View를 활용할 수 있음을 알 수 있었다. 이 연구를 통하여 어깨충돌 증후군뿐만 아니라 견관절 질환에서의 다양한 적용을 기대해 본다.

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

다기능 파노라마 방사선촬영장치를 이용한 하악해면골질의 평가 (Assessment of Cancellous Bone of Mandible by Multifunctional Panoramic X-Ray Machine)

  • 고재경;김재덕
    • Imaging Science in Dentistry
    • /
    • 제30권1호
    • /
    • pp.16-22
    • /
    • 2000
  • Purpose : To evaluate the bone densities measured on copper-equivalent image of cross sectional view of mandibular edentulous premolar area obtained by multifuctional panoramic x-ray machine, PM 2002 CC with transversal slicing system. Materials and Methods: Panoramic cross sectional views with 8 mm focal layer of aluminum step and blocks, of hydroxyapatite (RA) step, 6 HA blocks and copper step wedge having 0.03 mm thickness of each step, and of 3 bone blocks cutted by 8 mm thickness mesiodistally and a dry mandible with copper step wedge were taken by using transversal slicing system in PM 2002 Cc. All reference-equivalent images were made and analyzed by NIH image program. Results: The average copper-equivalent value of cancellous bone of bone blocks on the panoramic cross sectional view was 0.026 ± 0.020 mm Cu. The calculated average bone density was 0.38g/cm². There was no significant difference (P>0.1) between the bone densities on intraoral digital view and on the panoramic digital cross sectional view. Conclusion: The copper-equivalent image of panoramic digital cross sectional view obtained by PM 2002 CC with very thin copper step wedge was supposed to be useful to measure the bone density of cancellous bone of mandible at the premolar edentulous area.

  • PDF

Sparse 표현을 이용한 X선 흡수 영상 개선 (X-ray Absorptiometry Image Enhancement using Sparse Representation)

  • 김형일;엄원용;노용만
    • 한국멀티미디어학회논문지
    • /
    • 제15권10호
    • /
    • pp.1205-1211
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위해 X 선 영상에서 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도는 X 선 영상에서 뼈가 분리되고, 분리된 영역에서의 픽셀에 의해 BMD가 측정되는데, 개선된 영상에서의 정밀한 뼈 추출이 주요한 요소이므로 X 선 영상의 개선은 골다공증의 조기 진단을 위해 필수적이다. 본 논문에서는 sparse 표현을 도입하여 다중(multiple) 잡음을 갖는 X 선 영상을 개선시키는 방법을 제안한다. 실험을 통해 제안한 방법의 결과가 기존의 방법인 웨이블릿 BayesShrink 잡음 제거 방법 및 일반적 sparse 표현 모델의 잡음 제거 방법의 결과에 비해 개선됨을 CNR(Contrast to Noise Ratio) 및 cut-view를 통해 확인하였다.

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

다수의 2차원 단층영상으로부터 3차원 영상을 합성하기 위한 Angular 스펙트럼의 적용 (On the application of angular spectrum for synthesizing a 3-D image from a series of 2-D images)

  • 양훈기;이상이;김은수
    • 한국통신학회논문지
    • /
    • 제21권7호
    • /
    • pp.1668-1676
    • /
    • 1996
  • This paper presents the evaluation of an angular spectrum-based method used to calculate scattering pattern of a three-dimensional object modelled as a collection composed of vertical sectional two-dimensional images. This is done via comparing a proposed method with two existing methods, i.e., a Fresnel hologram method and a ray-tracing method, in terms of computatioal complexities and reconstructed results. Maathematical derivations for each methods are reviewed and implementing procedures are described in detail, along with the amount of computaions required from the implementation point of view, rather than from the mathematical point of view. We show simulation results in which the Fresnel holoram method dose not exhibit promising results although it requires the least computation. Moreover, it is also shown that the proposed method, even with much less computational requirement than the ray-tracing method, produces good performances asmuch as the ray-tracing method does.

  • PDF

Fast Measurement of Eyebox and Field of View (FOV) of Virtual and Augmented Reality Devices Using the Ray Trajectories Extending from Positions on Virtual Image

  • Hong, Hyungki
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.336-344
    • /
    • 2020
  • Exact optical characterization of virtual and augmented reality devices using conventional luminance measuring methods is a time-consuming process. A new measurement method is proposed to estimate in a relatively short time the boundary of ray trajectories emitting from a specific position on a virtual images. It is assumed that the virtual image can be modeled to be formed in front of one's eyes and seen through some optical aperture (field stop) that limits the field of view. Circular and rectangular shaped virtual images were investigated. From the estimated ray boundary, optical characteristics, such as the viewing direction and three dimensional range inside which a eye can observe the specified positions of the virtual image, were derived. The proposed method can provide useful data for avoiding the unnecessary measurements required for the previously reported method. Therefore, this method can be complementary to the previously reported method for reducing the whole measurement time of optical characteristics.

GALAXY CLUSTERS IN GAMMA-RAYS: AN ASSESSMENT FROM OBSERVATIONS

  • REIMER OLAF
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.307-313
    • /
    • 2004
  • Clusters of galaxies are believed to constitute a population of astrophysical objects potentially able to emit electromagnetic radiation up to gamma-ray energies. Evidence of the existence of non-thermal radiation processes in galaxy clusters is indicated from observations of diffuse radio halos, hard X-ray and EUV excess emission. The presence of cosmic ray acceleration processes and its confinement on cosmological timescales nearly inevitably yields in predicting energetic gamma-ray emission, either directly deduceably from a cluster's multifreqency emission characteristics or indirectly during large-scale cosmological structure formation processes. This theoretical reasoning suggests several scenarios to actually detect galaxy clusters at gamma-ray wavelengths: Either resolved as individual sources of point-like or extended gamma-ray emission, by investigating spatial-statistical correlations with unidentified gamma-ray sources or, if unresolved, through their contribution to the extragalactic diffuse gamma-ray background. In the following I review the situation concerning the proposed relation between galaxy clusters and high-energy gamma-ray observations from an observational point-of-view.

PC기반 치과 CT용 고전압 펄스 발생장치 개발 (Development of PC based High Voltage Generator for Dental CT)

  • 김학성;오준용;송상훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF