• Title/Summary/Keyword: ViewRay

Search Result 384, Processing Time 0.025 seconds

Real Time Image Acquisition System using a Image Intensifier and Position Error Verification (영상증배관을 이용한 실시간 영상획득시스템과 위치오차검증)

  • Lee, Dong-Hoon;Kim, Nam-Hoon;Jeong, Jong-Beom
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.331-338
    • /
    • 2017
  • In this study, a portable x-ray generator was manufactured and a real-time image acquisition system was constructed using the image intensifier from the generated generator. We have developed a real - time position error verification system that can verify whether the artificial joint position is different from the initial image from the acquired image. The template image of the region of interest is extracted from the reference image using the pattern matching technique and compared with the image to be compared. As a result, It is shown that real - time position error verification is achieved by displaying the difference angle. This system is portable type, has a self-shielding facility, and the output of the irradiation device can be manufactured in a small size of 1kw and can be used as a portable type. In case of emergency patients in the non-destructive field for industrial use, It has proved effective for use in small areas such as feet.

Study on the Effectiveness of Radiological Technologist's Thyroid Shielding in Pediatric Paranasal Sinus X-ray Examination (어린이 부비동 엑스선 검사에서 검사자의 갑상선 차폐 효과성에 관한 연구)

  • Chang-Kyo Kwak;Jeong-Taek Kwon;Kwang-Je Lee;Il-Hwan Bae;Hye-Jung Kim;So-Mi Lee;Do-Byung Rhee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.197-203
    • /
    • 2024
  • During paranasal sinus X-ray examinations in children, the radiological technologist's thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist's could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

Vision-based Walking Guidance System Using Top-view Transform and Beam-ray Model (탑-뷰 변환과 빔-레이 모델을 이용한 영상기반 보행 안내 시스템)

  • Lin, Qing;Han, Young-Joon;Hahn, Hern-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.12
    • /
    • pp.93-102
    • /
    • 2011
  • This paper presents a walking guidance system for blind pedestrians in an outdoor environment using just one single camera. Unlike many existing travel-aid systems that rely on stereo-vision, the proposed system aims to get necessary information of the road environment by using just single camera fixed at the belly of the user. To achieve this goal, a top-view image of the road is used, on which obstacles are detected by first extracting local extreme points and then verified by the polar edge histogram. Meanwhile, user motion is estimated by using optical flow in an area close to the user. Based on these information extracted from image domain, an audio message generation scheme is proposed to deliver guidance instructions via synthetic voice to the blind user. Experiments with several sidewalk video-clips show that the proposed walking guidance system is able to provide useful guidance instructions under certain sidewalk environments.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Analysis of Gamma-ray Spectrum and Assessment of Corresponding Exposure Rate by Means of Response Matrix Method (Response Matrix에 의한 감마선(線) Spectrum 및 그 조사선량(照射線量) 해석(解析))

  • Kim, Seong-Kwan;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.3-14
    • /
    • 1986
  • A stud has been carried out for figuring out real photon spectrum from an observed gamma-ray spectrum by means of response matrix method, which is known one of the relatively convenient method for the estimation of exposure rate of a complex gamma ray field in comparison with graphical analysis and least square fitting of the measured spectrum. A 3'${\times}$3' cylindrical Nal(T1) scintillation detector in association with multichannel pulse height analyzer and six reference gamma ray sources covering the photon energy range of 0.05 to 2.0 MeV were used. In dividing the energy region for the construction of response matrix, two different approaches were attempted. One is dividing the entire energy region of interest into 20 bins, one of which corresponds to a width of 0.1 MeV to form $20{\times}20$ matrix, and another is dividing the 2 MeV region into 14 bins to form $14{\times}14$ matrix consists of $0.1(MeV)^{1/2}$ intervals assuming the resolution of the detector is dependent on square root of the incident photon energy. Inversion of thus constructed matrices was performed by a computor(P-E8/32) using the program attached to the end of this paper. The resultant exposure rates obtained by this method were in good agreement, within 10% with those calculated by ordinary formula widely used for a gamma-ray field of known energy and flux. It is concluded that the photen flux obtained by the response matrix constructed under the assumption of $E^{1/2}$ dependence is more realistic than that obtained by the matrix consist of identical energy bins in dosimetrical point of view.

  • PDF

Optical Approach for Increasing the Resolution of Displayed Multi-view Image from Projection Type of Auto-stereoscopic 3D Display System by Adopting a Commercial Spherical Lenticular Lens Sheet (프로젝션 기반 무안경 방식 멀티뷰 3D 디스플레이에서 구면 렌티큐라 렌즈 시트를 이용하여 재생된 입체영상의 해상도를 증가시키는 광학적 접근 방법)

  • Sohn, Young-Sub;Kim, Sung-Kyu;Sohn, Kwanghoon;Lee, Kwang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.147-153
    • /
    • 2012
  • Multi-view 3D displays based on a limited number of pixels have the problem that the stereo-scopic image has a low resolution because of increasing view number. To solve the problem of low resolution, we propose an optical approaching method that focuses the width of a unit pixel by using a commercial spherical shape lenticular lens sheet and increases the effective resolution by increasing the number of sources of light in the multi-view 3D display system based on projection type. The method was performed in such an order that several main derivable parameters were defined, and, through the theoretical and experimental result, the value of the contractible unit pixel width and the scalable effective resolution was derived in a given system environment. As a result, for the case that the ray of light from the projector transmitted the 25 LPI lenticular lens sheet which has the pitch size 1.016 mm, the focused unit pixel width was 0.19 mm and the scalable effective resolution was, at most, 5 times wider than the original one. In addition, the range of depth of focus was 1.496 mm, which shows us the range of thickness tolerances of commercial spherical shape lenticular lens sheet and sufficient optical alignment tolerances.

Analysis of Reducing Characteristics of Direct Reduced Iron using Blast Furnace Dust

  • Yun, Young Min;Chu, Yong Sik;Seo, Sung Kwan;Jeong, Jae Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.444-449
    • /
    • 2016
  • Industrial by-products generated by integrated iron and steel manufacture cause environmental pollution. The by-products contain not only iron element but also harmful substances. Therefore, in view of to waste recycling and environmental preservation, production of sponge iron using the by-product is considered an effective recycling method. In this study, reduction efficiency of pellets from blast furnace dust was measured. Metallization was found to be increased, as $C/Fe_{total}$ ratio and reaction time were increased. The pellets were formed into a globular shape, and calcined for 60 minutes at $1100^{\circ}C$ in an electric furnace. Phase changes were analyzed using an X-ray diffractometer. Microstructures of the pellets were observed by a scanning electron microscope.

Development of Post-Processor for Fire Simulation (화재 시뮬레이션을 위한 후처리장치 개발)

  • Hur S.;Chang J.;Hur N.
    • Journal of computational fluids engineering
    • /
    • v.7 no.3
    • /
    • pp.27-34
    • /
    • 2002
  • When caught in a fire inside a building or a tunnel the generated smoke is the main cause of the bad visibility, which makes it difficult for a person to find escape route. Therefore of the fire simulation it is required to visualize the simulated results of smoke realistically form a viewpoint of a person caught in a fire. In the present study, developed is a CFD post-processor which can visualize the object through smoke from the results of CFD fire simulation. Examples of some applications of the program are shown in the paper.