• Title/Summary/Keyword: View Angle

Search Result 798, Processing Time 0.032 seconds

A New Anterior Approach for Fluoroscopy-guided Suprascapular Nerve Block - A Preliminary Report -

  • Kang, Sang-Soo;Jung, Jae-Woo;Song, Chang-Keun;Yoon, Young-Jun;Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.168-172
    • /
    • 2012
  • Background: The aim of the study was to investigate the feasibility of fluoroscopy-guided anterior approach for suprascapular nerve block (SSNB). Methods: Twenty patients with chronic shoulder pain were included in the study. All of the nerve blocks were performed with patients in a supine position. Fluoroscopy was tilted medially to obtain the best view of the scapular notch (medial angle) and caudally to put the base of coracoid process and scapular spine on same line (caudal angle). SSNB was performed by introducing a 100-mm, 21-gauge needle to the scapular notch with tunnel view technique. Following negative aspiration, 1.0 ml of contrast was injected to confirm the scapular notch, and 1 % mepivacaine 2 ml was slowly injected. The success of SSNB was assessed by numerical rating scale (NRS) before and after the block. Results: The average NRS was decreased from $4.8{\pm}0.6$ to $0.6{\pm}0.5$ after the procedure (P < 0.05). The best view of the scapular notch was obtained in a medial angle of $15.1{\pm}2.2$ ($11-19^{\circ}$) and a caudal angle of $15.4{\pm}1.7^{\circ}$ ($12-18^{\circ}$). The average distance from the skin to the scapular notch was $5.8{\pm}0.6$ cm. None of the complications such as pneumothorax, intravascular injection, and hematoma formation was found except one case of partial brachial plexus block. Conclusions: SSNB by fluoroscopy-guided anterior approach is a feasible technique. The advantage of using a fluoroscopy resulted in an effective block with a small dose of local anesthetics by an accurate placement of a tip of needle in the scapular notch while avoiding pneumothorax.

DECISION OF PROPER PROJECTION ANGLE AND EVALUATION OF REPRODUCIBILITY IN TRANSCRANIAL RADIOGRAPH (악관절규격촬영시 적절한 입사각의 결정 및 재현성의 평가)

  • Ryu Jung-Soo;Choi Soon-Chul;Lee Sang-Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.99-107
    • /
    • 1991
  • The purpose of this study was to decide the proper projection angle that could avoid the superimposition of the petrous portion of temporal bone and posterior clinoid process in cephalometric lateral and basal view of the 10 dry skulls and to analyze the reproducibility of a modified Accurad-100 head holder device from Denar Co. and a cephalostat head holder in 30 transcranial radiographs of the dry skull. The results were obtained as follows: The vertical angle was 24.5±4.1° and the horizontal angle was 3.0 ±5.7°. The distances between arbitrary 3 points which were on the TMJ area were as follows: AB 16.76±0.27㎜, BC 8.79±0.18㎜ in the transcranial radiographs using modified Accurad-100 head holder, AB 29.03±0.14㎜, AC 19.95±0.24㎜, BC 10.08±0.07㎜ in the transcranial radiographs using cephalostat.

  • PDF

ISAR Imaging Using Rear View Radars of an Automobile (후방 감시 차량용 레이다를 이용한 ISAR 영상 형성)

  • Kang, Byung-Soo;Lee, Hyun-Seok;Lee, Seung-Jae;Kang, Min-Suk;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.245-250
    • /
    • 2014
  • This paper introduces the inverse synthetic aperture radar(ISAR) imaging technique for rear view target of an automobile, which uses both linear frequency modulation-frequency shift keying(LFM-FSK) waveform and monopulse tracking. LFM-FSK waveform consists of two sequential stepped frequency waveforms with some frequency offset, and thus, can be used to generate ISAR images of rear view target of an automobile. However, ISAR images can often be blurred due to non-uniform change rate of relative aspect angle between radar and target. In order to address this problem, one-dimensional(1-D) Lagrange interpolation technique in conjunction with angle information obtained from the monopulse tracking is applied to generate uniform data across the radar's aspect angle. Simulation results show that the proposed method can provide focused ISAR images.

Impact Angle Control with Time Varying Continuous Biased PNG for Non-maneuvering Target (시변 연속적 편향 비례항법 유도법칙을 이용한 이동표적의 충돌각 제어)

  • Park, Jang-Seong;Kwon, Hyuck-Hoon;Park, Sang-Hyuck;Kim, Yoon-Young;Park, Bong-Gyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.742-751
    • /
    • 2018
  • In this paper, we propose a time varying biased proportional navigation guidance law that controls the impact angle under Field-of-View(FOV) and the acceleration limit of the missile. The proposed law is composed of three stages in consideration of the FOV limitation. Since the bias directly affects the acceleration at each stage, the final bias value of the previous stage becomes the initial bias value of the next stage when the stage is switched. In addition, the impact angles were controlled by judging whether impact angles were reached in consideration of engagement conditions and physical constraints.

Broden photographing method for Calcaneus Subtentaculum tali observation of Ankle plaster patient (발목부상을 당한 석고환자의 발꿈치뼈·목말받침돌기 관찰을 위한 Broden 촬영법 연구)

  • An, Byeongju
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • There is an Ankle Oblique(Broden' low) as an examination for the patient whose ankle was encased in orthopedic plaster. Some types of Ankle Joint coalition - Calcaneonavicular coalition, Talocalcaneal coalition and Naviculocuneiform coalition. This study is focused on the relation between Ankle Joints and the structural change of soft tissues, also finding the most proper angle to obtain good images of Ankle Joint from the patient who wore a plaster on his ankle, when we x-ray with Harris-Beath View($30^{\circ}{\sim}55^{\circ}$) - for observing Subtalar joint, Calcaneus Fracture, Subtentaculum, Tali Fracture and Talocalcaneal coalition. We intend to get the angle which makes us achieve the good image that shows Calcaneus Fracture, Subtentaculum, and Tali Fracture by changing internal angles of the patient's ankle. We evaluated the images obtained from 51 patients with PACS monitor. The result of the evaluation, subtalar joint was not seperated but opened, and Subtentaculum Tali Fracture was seen overlaid. at the angle 30, we could observe Calcaneus Fracture, Subtentaculum Tali Frature and the front part of behind side of subtalar joint well. And Calcaneo Navicularcoalition, Talocal Canealcoalition, Naviculo Cuneiform coalition condition were clearly seen at that angle. At the angle 35, we could achieve the clear images of subtalar comminuted fracture, talus, the behind joint of heel bone and get the high definition image on the degree of talocalcaneal joint separation. In addition to, We could obtain the good wide image of Sinus Tarsi. At the area of 45, We can distinguish the soft tissues from gyps separation. The outer-talus and density of the bone were definitely seen and Calcaneus is more separated than that of at the angle of 35, but this image is distorted. Calcaneus, Subtentaculum Tali show $1.20{\pm}0.414$ at the angle 25, $2.47{\pm}0.516$ at the angle 30, $2.27{\pm}0.458$ at the angle 45. This difference is statistically meaningful. (p<0.05). Including the degree of distortion, The distortion appears less at the area of $30^{\circ}$ but at the area of 40, there is heavy distortion. So, We could get the best image for making a diagnosis. At the $30{\sim}35^{\circ}$ degree for X-raying ankle. and at the $30{\sim}40^{\circ}$ for Calcaneus Fracture, Subtentaculum Tali Fracture.

Lowest-Cost Highest-Yield Superior Performance MVA LCDs by Amplified Intrinsic Fringe Field

  • Ong, Hiap L.;Liang, Justin;Guo, Jia Haw;Chen, I Hao;Wu, Chang Lin;Lan, Wei-Chou;Lin, Tung-Liang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1645-1648
    • /
    • 2008
  • We successfully fabricated lowest-cost superior perform ance MVA LCDs with highest-yield, high transmission, high contrast-ratio, and wide viewing angle. Using the amplified intrinsic fringe field (AIFF) controlled MVA invented by Ong, we eliminated all protrusions and ITO slit geometries. We further achieved: (1) faster gray-gray response times without the over-drive technology, (2) faster tough mura, and (3) lower flicker and cross-talk in the row inversion driving schemes.

  • PDF

Hologram Generation of 3D Objects Using Multiple Orthographic View Images

  • Kim, Min-Su;Baasantseren, Ganbat;Kim, Nam;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.269-274
    • /
    • 2008
  • We propose a new synthesis method for the hologram of 3D objects using incoherent multiple orthographic view images. The 3D objects are captured and their multiple orthographic view images are generated from the captured image. Each orthographic view image is numerically overridden by the plane wave propagating in the direction of the corresponding view angle and integrated to form a point in the hologram plane. By repeating this process for all orthographic view images, we can generate the Fourier hologram of the 3D objects.

A Study on the Shapes of Women′s Neck and Shoulder in Dressmaking I (의복설계를 위한 성인여성의 經部 및 肩部의 유형화 I)

  • 김희숙
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.668-680
    • /
    • 2000
  • The study presents the general types and individual differences of the shape of the adult women's neck and shoulder in our country. It is based on the average value, the standard deviation, the maximum value, the standard deviation, the maximum value, the minimum value and c.v. measured from the women at the age of 19 through 64. The results of this study are as follows ; 1. The factors by factor analysis are five. The first is the size factors of the neck and shoulder. The second is shape factor of neck. The third is plane view and length factor of the neck. The fourth is the side view factor of the neck and shoulder. The fifth is the shape factor of shoulder. Therefore the shape of the neck and shoulder should be examined in the shape factors as well as in the size factors as well as in the size factors for the designing body-suitable clothes. 2. The factors of the concrete objects are the solid view of neck and shoulder, the cross-sectional view of neck line, side view of neck and shoulder and length of neck. The explainable measuring items for the factors are the difference of the length between lower neck round line and the 4㎝ above neck round line, the length of neck, the angle of inclination between fore neck and back neck, the angle of inclination of the side shoulder, the difference of the height between fore neck point and back neck point, the width of shoulder, the width of chest and the width of back. 3. The concrete objects of the neck and shoulder have five types ; Type Ⅰ is average type, Type Ⅱ is thick short neck and the drooping shoulder type, Type Ⅲ I is slender long neck and lean-back shoulder type, Type Ⅳ is thick and rising shoulder type and Type Ⅴ is slender and drooping shoulder type.

  • PDF

Look-Angle-Control Guidance for Missiles with Strapdown Seeker (스트랩다운 탐색기를 탑재한 유도탄의 관측각 제어 유도)

  • Kim, Dowan;Park, Woosung;Ryoo, Chang-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.275-280
    • /
    • 2013
  • Conventional proportional navigation guidance law is not adequate for missiles with a strapdown seeker, because the strapdown seeker cannot measure line-of-sight rate directly. This paper suggests a guidance loop design method, in which the look angle, measured by the strapdown seeker directly, is controlled to deliver a missile to a target. Basically, the look angle control loop is regarded as an attitude control loop. By using the proposed method, it is possible to shape the midcourse trajectory by choosing the reference look angle properly. The look angle control loop can robustly maintain target lock-on against disturbances because the target is always captured in the field of view of the seeker. The performance of the proposed method is verified via 6-DOF simulations of a true short range tactical missile model.

Parametric Study of Composite Laminated Conical Shells (복합적층 원뿔형 쉘의 파라미터 연구)

  • Son, Byung-Jik;Jung, Dae-Suck
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.5
    • /
    • pp.41-49
    • /
    • 2007
  • In general, the curved structures have the engineering efficiency as well as a fine view compared with straight member. Also, composite materials are composed of two or more different materials to produce desirable properties for structural strength as compared to single ones. Shell structures with composite materials have many advantages in strength and weight reduction. Therefore, composite laminated conical shells are analyzed in this study. To solve differential equations of conical shells, this paper used finite difference method. Various parametric study according to the change of radius ratio, vertex angle and subtended angle are examined. The change of radius ratio, vertex angle and subtended angle mean the change from conical shells to cylindrical shells, conical shells to circular plates and open shells closed shells, respectively.