Evaluation of Mechanical Properties and Microstructure Depending on Sintering Heating Rate of IN 939 W Alloy (IN 939 W 합금의 소결 승온 속도에 따른 물리적 특성과 미세조직 분석)

  • Jeon, Junhyub;Lee, Junho;Seo, Namhyuk;Son, Seung Bae;Jung, Jae-Gil;Lee, Seok-Jae
    • Journal of Powder Materials
    • /
    • v.29 no.5
    • /
    • pp.399-410
    • /
    • 2022
  • Changes in the mechanical properties and microstructure of an IN 939 W alloy according to the sintering heating rate were evaluated. IN 939 W alloy samples were fabricated by spark plasma sintering. The phase fraction, number density, and mean radius of the IN 939 W alloy were calculated using a thermodynamic calculation. A universal testing machine and micro-Vickers hardness tester were employed to confirm the mechanical properties of the IN 939 W alloy. X-ray diffraction, optical microscopy, field-emission scanning electron microscopy, Cs-corrected-field emission transmission electron microscopy, and energy dispersive X-ray spectrometry were used to evaluate the microstructure of the alloy. The rapid sintering heating rate resulted in a slightly dispersed γ' phase and chromium oxide. It also suppressed the precipitation of the η phase. These helped to reinforce the mechanical properties.

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

The effect of varnish fluoride on the acid resistance and the remineralization of the enamel (불소바니쉬가 법랑질의 내산성 및 재광화에 미치는 영향)

  • Cho, Min-Jung;Shim, Hyung-Soon;Lee, Hyang-Nim;Kim, Seung-Hee;Park, Ji-Il;Kim, Eun-Mi;Ha, Myung-Ok
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.4
    • /
    • pp.740-752
    • /
    • 2009
  • Objectives : This study was carried out to examine the effect of varnish fluoride and APF gel on the acid resistance and the remineralization of the enamel. Methods : At first, the microhardness changes of enamel surface were measured after demineralizing the fluoride treated tooth surface. Next, the changes were measured after fluoride application to the demineralized enamel surface. Results : 1. Acid resistance was higher in varnish fluoride groups than APF gel groups and the difference was significant(p<0.001). 1) Varnish fluoride groups Microhardness of enamel surface showed $297.76{\pm}9.89$ after fluoride treatment and $260.90{\pm}28.67$ after drmineralization. The changes of Vickers hardness number(VHN) were $-36.86{\pm}27.30$. 2) APF gel groups Microhardness of enamel surface showed $298.79{\pm}17.28$ after fluoride treatment and $43.75{\pm}18.58$ after demineralization The changes of VHN were $-255.04{\pm}21.31$. 2. No significant changes were surveyed in both varnish fluoride groups and APF gel groups as for remineralization of enamel(p>0.05). 1) Varnish fluoride groups Microhardness of enamel surface showed $46.58{\pm}15.42$ after demineralization and $46.61{\pm}15.70$ after fluoride treatment. The changes of VHN were $0.02{\pm}3.75$. 2) APF gel groups Microhardness of enamel surface showed $47.13{\pm}19.31$ after demineralization and $42.59{\pm}16.12$ after fluoride treatment. The changes of VHN were $-4.54{\pm}5.06$. Conclusions : Varnish fluoride showed higher acid resistance than APF gel, however both of them were observed to have no effect on the remineralization of the enamel.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER (아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구)

  • Ju, Sang-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF

THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY (도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구)

  • Kim, Seung-Soo;Cho, Sung-Sik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

Influence of resin-nanoceramic CAD/CAM block shade and thickness on the microhardness of dual-cured resin cement (레진-나노세라믹 CAD/CAM블록의 색조와 두께가 이원중합 레진시멘트의 미세경도에 미치는 영향)

  • Choi, Ga-Young;Park, Jeong-Kil;Jin, Myoung-Uk;Kwon, Yong Hoon;Son, Sung-Ae
    • Korean Journal of Dental Materials
    • /
    • v.44 no.2
    • /
    • pp.151-161
    • /
    • 2017
  • The purpose of this study was to examine the effect of shade and thickness of resin-nanoceramic CAD-CAM block (RNB) on the microhardness of dual-cured resin cement, as well as to measure the number of photons transmitted through RNBs of different thicknesses and colors. One dual-cured resin cement was used to prepare resin cement specimens. Resin cement specimens were light-cured for 40 seconds through 3 shades (A1, A2, A3 in HT (high translucency) and LT (low translucency) respectively) and four thicknesses (1, 2, 3, 4 mm) of RNB specimens. Vickers microhardness measurements of resin cement specimens were performed using a Vickers hardness tester. The light transmission of RNB specimens was measured using a spectrometer (SpectroPro-500, Acton Research, Acton, MA, U.S.A.), and the translucency parameter was calculated using the CIEL*a*b* system. Data were statistically analyzed by ANOVA and Tukey's test. There was a significant decrease of microhardness of resin cement specimen with an overlay of 4 mm of RNB thickness and A3 shade in comparison to A1 and 1 mm, respectively (p<0.05). The translucency parameter values and light transmission of RNBs tested differed significantly, according to the thicknesses of the specimen (p<0.05). Light transmission is decreased with increase in the thicknesses of RNBs. Shade A1 transmitted more light than darker blocks. A decrease in microhardness of resin cement specimens was observed with increasing thickness and shade (A1 to A3) of RNBs.

The Surface Characteristics of Enamel according to Fluoride Application Methods and Frequency (불소 도포 방법과 적용 횟수에 따른 법랑질의 표면 특성)

  • Jang, Sun-Ok;Choi, Eun-Mi;Oh, Sang-Hwan;Kang, Min-Kyung;Kim, Kwang-Man
    • Journal of dental hygiene science
    • /
    • v.11 no.2
    • /
    • pp.69-76
    • /
    • 2011
  • The aim of this study was to compare the effects on the resistance to demineralization by the frequency and method of fluoride application in vitro. ninety-one human enamel specimens were embedded in acrylic resin with the labial surfaces exposes. The specimens were divided into 7 groups; (1) non-treated; (2) 1.23% APF gel 1 time; (3) 2% NaF sol 1 time; (4) 2% NaF sol iontophoresis 1 time; (5) 1.23% APF gel 4 time; (6) 2% NaF sol 4 time; (7) 2% NaF sol iontophoresis 4 time. All the groups were immersed in the remineralizing solution (RS) before baseline and divided into 7 test groups of 13 specimens each. All the specimens were exposed to a pH-cycling model which consisted of demineralization (6 hours) and remineralization (18 hours) for 5 days. The Vickers surface micro-hardness number of all the specimens was measured using microhardness tester and the specimen surfaces were observed by scanning electron microscope (SEM). The results were analyzed using one-way ANOVA followed a Tukey's multiple comparison at a significance level of 0.05. The group 7 showed higher level of microhardness after Fluoride application. The group 1 showed lowest level of microhardness but group 7 showed higher level of microhardness after pH-cycling model, there were significant differences between groups. After the modified pH-cycling, the 2% NaF solution with the iontophoresis group showed the best resistance to demineralization(p<0.05). These results were also confirmed by SEM. The fluoride iontophoresis method was the most effective of the regimens in increasing the acid resistance of the enamel.

Effect of 15% Hydrogen Peroxide on Color Change and Microhardness of Bovine Teeth according to the Time (15% Hydrogen Peroxide 전문가용 치아미백 후 시간경과에 따른 색상변화와 미세경도의 변화)

  • Park, Mi-Young
    • Journal of dental hygiene science
    • /
    • v.13 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • This study evaluated the change of color and the microhardness according to time-out using the office bleaching with in vitro test after bleaching one time 1 day per week, total three times, for the control group and three times per 1day for the experimental group. $L^*$ was increased in both groups. Group 1 showed a significant increase statistically between before and after tooth whitening (p<0.05). Group 2 showed a significant increase statistically between before and after tooth whitening (p<0.05). ${\Delta}E^*$ was huge in both groups. In group 1, it was great in terms of statistical significance between 1 day and 7 days after tooth whitening (p<0.05). In group 2, it was the greatest between before and 1 day after tooth whitening and was significant statistically as well (p<0.05). Vickers hardness number (VHN) decreased in both groups. In group 1, VHN decreased over time and the difference was significant statistically (p<0.05). In group 2, VHN decreased over time and the difference was significant statistically (p<0.05). Percentage microhardness loss was great in both groups. In group 1, it was the greatest between 1 day and 7 days after the treatment, and it was significant statistically (p<0.05). In group 2, it was the greatest between before and 1 day after the treatment, and it was significant statistically (p<0.05). Put together, the more frequent tooth whitening a day is, the longer the period of tooth whitening when applying the same frequency, the greater color change was, however the microhardness decreased, in regard to the results over time using 15% hydrogen peroxide tooth whitening product for professionals.