• 제목/요약/키워드: Vibrational Measurement

검색결과 70건 처리시간 0.023초

Raman Spectroscopy of Irradiated Normoxic Polymethacrylic Acid Gel Dosimeter

  • Bong, Ji-Hye;Choi, Kyu-Seok;Yu, Soo-Chang;Kwon, Soo-Il;Cho, Yu-Ra;Park, Chae-Hee;Park, Hyung-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권2호
    • /
    • pp.625-629
    • /
    • 2011
  • A quantitative analysis of the decreasing rate of the monomer and increasing rate of the polymerization was made by monitoring radiation level increments using Raman spectroscopy within the therapeutic radiation range for a normoxic polymethacrylic acid gel dosimeter. The gel dosimeter was synthesized by stirring materials such as gelatin, distilled water, methacrylic acid, hydroquinone and tetrakis phosphonium chloride at $50^{\circ}C$, and the synthesized gel was contained in a 10- mm diameter and 32-mm high vial to conduct measurement. 24 hours after gel synthesis, it was irradiated from 0 Gy to 20 Gy by 2 Gy using a Co-60 radiotherapy unit. With use of the Cryo FE-SEM, structural changes in the 0 Gy and 10 Gy gel dosimeters were investigated. The Raman spectra were acquired using 532-nm laser as the excitation source. In accordance with fitting the changes in C-COOH stretching (801 $cm^{-1}$), C=C stretching (1639 $cm^{-1}$) and vinyl $CH_2$ stretching (3114 $cm^{-1}$) vibrational modes for monomer and $CH_2$ bending vibrational mode (1451 $cm^{-1}$) for polymer, sensitive parameter S for each mode was calculated. The values of S for monomer bands and polymer band were ranged in $6.0{\pm}2.6$ Gy and $7.2{\pm}2.3$ Gy, respectively, which shows a relatively good conformity of the decreasing rate of monomer and the increasing rate of polymerization within the range of error.

Physiological and Psychological Effects of Vibroacoustic Stimulation to Scapular and Sacrum of Supine Position

  • Lim, Seung Yeop;Heo, Hyun;Kim, Sang Ho;Won, Byeong Hee
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.345-353
    • /
    • 2013
  • Objective: This research measured physiological and psychological effects of Vibroacoustic stimulation(VA) to scapular and sacrum of supine position on the mattress. Background: When vibroacoustic stimulation applies to human body, it has a positive influence on physiological and psychological effects by stimulating the organs, tissues and cells of whole body. Method: This experiment was conducted to 10 normal males in two conditions: no stimulation and vibroacoustic stimulation. No stimulation experiment was executed as a supine position for 30 minutes without any vibrational stimulus, while vibroacoustic stimulation was transmitted by the vibrational speaker, which uses 40Hz frequency. Subjects had a laser Doppler flowmeter probe in scapular, sacrum, and also had 8 channel electroencephalogram(EEG) measurement sensor in the scalp. Blood pressure and skin temperature were measured in two conditions with an underlying posture for 30 minutes. Additionally, blood flow rate and EEG were measured before and after for two minutes on two conditions. Results: According to the vibroacoustic stimulation, blood flow rate and skin temperature were increased, while blood pressure was decreased. When using vibroacoustic stimulation compared to no stimulation, blood flow rate went approximately two times higher, and skin temperature also higher 3~4 times. Furthermore, the relative alpha power of brain wave was significantly increased when we applied to vibroacoustic stimulation. Conclusion: This experiment tested the VAT embedded in mattress in two conditions. According to this experiment, VAT decreases blood pressure, improves not only a physiological effect on blood flow rate as well as skin temperature, but also psychological functions by increasing relative alpha power. Application: The results of the publishing trend analysis might help physiological and psychological effects of vibroacoustic stimulation.

Extracting Frequency-Frequency Correlation Function from Two-Dimensional Infrared Spectroscopy: Peak Shift Measurement

  • Kwak, Kyung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권10호
    • /
    • pp.3391-3396
    • /
    • 2012
  • Two-dimensional infrared (2D-IR) spectroscopy can probe the fast structural evolution of molecules under thermal equilibrium. Vibrational frequency fluctuation caused by structural evolution produced the time-dependent line shape change in 2D-IR spectrum. A variety of methods has been used to connect the evolution of 2D-IR spectrum with Frequency-Frequency Correlation Function (FFCF), which connects the experimental observables to a molecular level description. Here, a new method to extract FFCF from 2D-IR spectra is described. The experimental observable is the time-dependent frequency shift of maximum peak position in the slice spectrum of 2D-IR, which is taken along the excitation frequency axis. The direct relation between the 2D-IR peak shift and FFCF is proved analytically. Observing the 2D-IR peak shift does not need the full 2D-IR spectrum which covers 0-1 and 1-2 bands. Thus data collection time to determine FFCF can be reduced significantly, which helps the detection of transient species.

Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system

  • Shin, S.;Park, M.S.;Jang, J.H.;Ky, Y.H.;Suh, J.S.
    • Korea-Australia Rheology Journal
    • /
    • 제16권3호
    • /
    • pp.129-134
    • /
    • 2004
  • The aggregation characteristics of red blood cells (RBCs) were measured using a newly developed light-transmission slit rheometer. Conventional methods of RBC disaggregation such as the rotational Couette system were replaced with a pressure-driven slit flow system with a vibrational mechanism. Using a vibration generator, one can disaggregate the RBC aggregates stored in the slit. While shear stress decreases exponentially, instantaneous pressure and the transmitted light intensity were measured over time. Applying an abrupt shearing flow after disaggregation caused a rapid elongation of the RBCs followed by loss of elongation with the decreasing shear stress. While the shear stress is further decreasing, the RBCs start to re-aggregate and the corresponding transmitted intensity increases with time, from which the aggregation indices can be obtained using a curve-fitting program.

고속철도 운행에 의한 진동전달특성 및 인접건물에 미치는 영향에 관한 연구 (A Study on the Characteristics of Transferring Vibration and Effect of Nearby-Building Induced by the High-speed Train in Operation)

  • 배동명;신창혁;최철은;박상곤;백용진
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.354-364
    • /
    • 2001
  • The vibration induced by high speed train running on rail is dealt with as an environmental problem. The train induced vibration is characterized by moving loads at specific frequencies and soil conditions. In fact, it is predicted that the vibration sources are involved the wheel distance, number of cars, speed of operation, drift of rails, structural born vibration, etc. In this paper the characteristics of transferring vibration induced by the high-speed train in operation is discussed. Field measurements was conducted at region from Chungnam Yungj So-jung-myan to Chungbuk Chungwon hyun-do-myun. In the near future. these data will be used as the fundamental data for establishment of the countermeasure for vibrational reduction of high speed train using the results of the field measurements and quantitative prediction of the vibration level

  • PDF

레이저 유도 형광법(LIF)을 이용한 층류 비예혼합 $H_2/N_2$화염에서의 NO 농도측정에 관한 연구 (A Study on Measurement of NO Concentrations in Laminar Nonpremixed $H_2/N_2$ Flame by LIF)

  • 김성욱;진성호;김경수;박경석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제22회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.133-138
    • /
    • 2001
  • In this study, quantitative nitric oxide concentration distributions are investigated in the laminar nonpremixed $H_2/N_2$ flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different $N_2$ dilution ratios varying from 20${\sim}$80%, and fuel now rate is fixed as lslpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. We applied same excitation line used in $CH_4$ premixed flame. Overall, NO concentration was rapidly decreased with $N_2$ addition and we could not measure the concentration any longer for $N_2$ dilution above 80%.

  • PDF

시간-주파수 분석을 이용한 파이프 부식감시 (Application of Time Frequency Analysis to On Line Monitoring of Pipe Corrosion)

  • 박기용;이철권;이상정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2616-2618
    • /
    • 2005
  • Time-frequency analysis (TFA) method was applied to identify the integrity of the internal local surface of a pipe where some chemical corrosions are likely to occur by acid mixed in the coolant of nuclear power plants. The spalling out of internal material pieces by corrosion induces some transient signals and the change of structural vibration of a local point in the pipe. It is therefore possible to detect the corrosion detachment through the measurement of the transient acoustic signals or the vibration signals. In this presentation, the TFA was configured on the vibrational signal data of the pipe and it is identified that the TFA can Provide an important information, i.e., the amplitude fluctuations in the instantaneous frequency of each characteristic frequency.

  • PDF

평면 레이저 유도 형광법(PLIF)을 이용한 $CH_4/O_2N_2$ 예혼합화염의 NO 농도 분포 가시화에 관한 연구 (A Study on the Visualization of NO Concentration Distributions in $CH_4/O_2N_2$ Premixed Flames by PLIF)

  • 박경석;이세환
    • 한국분무공학회지
    • /
    • 제6권3호
    • /
    • pp.1-7
    • /
    • 2001
  • In this study, quantitative measurement of nitric oxide concentration distributions visualization were investigated in the laminar $CH_4/O_2N_2$ nixed flame by Planar laser-induced fluorescence(PLIF). The NO A-X (0,0) vibrational band around 226nm was excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interference from Rayleigh scattering and $O_2$ fluorescence. The measurements were taken in $CH_4/O_2N_2$ premixed flame with equivalence ratios varying from $1.0{\sim}1.6$, and a fixed flow rate of 3slpm. NO was found to produce primarily between an inner premixed and an outer nonpremixed flame front, and total NO concentration is raised when equivalence ratios increase. These results suggest that prompt NO is likely to contribute to MO formation in $CH_4/O_2N_2$ premixed flame. Furthermore, this trend was well matched with previous works.

  • PDF

레이저 유도 형광법(LIF)을 이용한 층류 메탄 예혼합 화염내 NO 농도측정에 관한 연구 (A Study on Measurement of NO Concentrations in Laminar Premxied $CH_4/O_2/N_2$ Flames by LIF)

  • 김성욱;진성호;김경수;박경석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.156-161
    • /
    • 2000
  • In this study, quantitative nitric oxide concentration distributions are investigated in the post-flame zone of laminar premixed $CH_4/O_2/N_2$, flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different equivalence ratios varying from $0.8{\sim}1.4$, and flow rate is fixed as 5slpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interferences from Rayleigh scattering and $O_2$ fluorescence. NO concentration is rised when equivalence ratios increase at different vertical distances form nozzle tip. In any case, the maximum NO concentration reaches the maximum in reaction zone.

  • PDF

풍력발전기용 증속기 상태 모니터링에 관한 기초 연구 (Preliminary study on the Condition Monitoring of Wind-turbine Gearbox)

  • 박영준;이재정;이근호;남용윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.343-346
    • /
    • 2008
  • To improve the reliability and extend the life for a wind-turbine gearbox, the gearbox needs to be monitored and analysed exactly. This study was conducted to analyze and detect the gearbox conditions when lubricating oil contaminated by wear particles was used. Characteristics of the gearbox failure by wear particles were monitored simultaneously by the on-line measurement sensor of vibration, oil condition and temperature. For the detail vibration analyses, frequency analysis(FFT) was performed. The results of the study were summarized as follows: Vibrational signal was found sensitive to abnormal changes of the gearbox conditions when lubricant was contaminated by wear particles. Also, using frequency analysis for the harmonics of gear mesh frequency(GMF), it is found that the failure of gearbox was caused by the damages of meshing gears. However, temperature and oil condition measuring signals were found not so effective to detect any gearbox failure by oil contamination.

  • PDF