Comparison of the Immediate Effect of the Whole-body Vibration on Proprioceptive Precision of the Knee Joint Between Barefoot and Shoe-wearing Conditions in Healthy Participants

  • Lee, Yu-bin;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.108-116
    • /
    • 2021
  • Background: Whole-body vibration (WBV) has been used to alleviate proprioceptive damage by musculoskeletal and neurological conditions. However, no study has determined whether wearing shoes while applying WBV can affect proprioception precision of the knee joint. Objects: This study aimed to determine the differences in the proprioceptive precision of the knee joint before and after WBV and to compare the proprioceptive precision of the knee joint between barefoot and shoe-wearing conditions. Methods: This study recruited 33 healthy participants. A passive-to-active angle reproduction test was used to measure the proprioception precision of the knee joint using an electrogoniometer, and the target angle was set to a knee flexion of 30°. Proprioception precision was calculated using the error angle (angular difference from 30°). Proprioceptive precision was measured in weight-bearing and non-weight-bearing positions before and after applying WBV for 20 minutes at 12 Hz in barefoot and shoe-wearing conditions. Mixed repeated analysis of variance was used to determine the differences in changes in the proprioceptive precision of the knee joint according to foot conditions. Results: There were significant improvements in the weight-bearing (p = 0.002) and non-weight-bearing (p < 0.001) proprioceptive precision of the knee joint after applying WBV. However, there was no significant difference in the change in proprioceptive precision of the knee joint after applying WBV between the barefoot and shoe-wearing conditions. Conclusion: WBV stimulation had an immediate effect on improving the proprioceptive precision of the knee joint. However, foot conditions (barefoot or shoe-wearing) during WBV application did not influence the proprioceptive precision of the knee joint.

Effects of Sling Exercise With Vibration on Range of Motion, Muscle Strength, Pain, Disability in Patients With Shoulder Injuries (진동을 동반한 슬링 운동이 어깨 손상 환자의 관절가동범위, 근력, 통증, 기능장애 수준에 미치는 영향)

  • Chi, Chang-yeon;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.11-22
    • /
    • 2019
  • Background: Sling exercises are frequently used for the rehabilitation process of patients with shoulder joint injuries, but research on the significant frequency intensity and appropriate treatment duration for sling exercises with local vibration stimulation is lacking. Objects: The aim of this study was to investigate the effects of sling exercise with vibration on shoulder range of motion (ROM), muscle strength, pain, and dysfunction in patients with a medical diagnosis of shoulder joint injury. Methods: Twenty-two patients were randomly assigned to the experiment and control groups. Six sling exercises with and without 50 Hz vibrations were applied in the experiment and control groups, respectively. Each exercise consisted of 3 sets of 5 repetitions performed for 6 weeks. The assessment tools used included shoulder joint range of motion, muscle strength, pain level, and shoulder pain and disability index for functional disability. We conducted re-evaluations before and 3 and 6 weeks after intervention. The changes in the measurement variables were analyzed and compared between the two groups. Results: The ROM of the external rotation of the shoulder joint had a significant interaction between the group and the measurement point (F=3.652, p<.05). In both groups, we found a significant increase in external rotation angle between the measurement points (p<.05). The flexor strength of the shoulder joint significant interaction between the group and the measurement point (F=4.247, p<.05). Both the experiment (p<.01) and control groups (p<.05) showed a significant increase in shoulder flexor strength at the measurement points. After 6 weeks of the interventions, both the groups showed significantly improved VAS (p<.01), SPADI (p<.01), and orthopedic tests (p<.01). However, there was no significant difference between the group and the measurement point in terms of the clinical outcomes observed. Conclusion: The sling exercise with local vibration of 50 Hz affected the external rotation of the shoulder range of motion and improved shoulder flexor strength in the patients with shoulder injuries. Therefore, we propose the use of the sling exercise intervention with vibration in the exercise rehabilitation of patients with shoulder joint injuries.

A Conceptual Design of an Integrated Tactile Display Device

  • Son, Seung-Woo;Kyung, Ki-Uk;Yang, Gi-Hun;Kwon, Dong-Soo;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2753-2758
    • /
    • 2003
  • Tactile sensation is essential for many manipulation and exploration tasks not only in a real environment but also in a virtual environment. In this paper, we discuss a conceptual design of an integrated tactile display system. The system comprises two parts: a 2 DOF force feedback device for kinesthetic display and a tactile feedback device for displaying the normal stimulation to skin and the skin slip/stretch. Psychophysical experiments measure the effects of fingerpad selection, the direction of finger movements and the texture width on tactile sensitivity. We also investigate characteristics of lateral finger movement while subjects perceive different textures. From the experimental results, the principal parameters for designing a tactile display are suggested. A tactile display device is implemented using eight piezoelectric bimorphs and a linear actuator, and is attached to a 2 DOF translational force feedback device to simultaneously simulate texture and stiffness of the object.

  • PDF

Development of Health Tools for Silver Longevity on the Theory of the Material Basis & Vital and Mental Activities (실버 장수양생을 위한 精氣神論的인 건강기구 개발)

  • Kim Gyeong Cheol;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.4
    • /
    • pp.893-897
    • /
    • 2003
  • We study the health tools for silver longevity on the theory of the material basis & vital and mental activities. The results are as follows. The navel herb-moxibustion tool strengthen material basis in the low elixir-field. The method is the fumigation of navel by the aroma of herb. The detailed micro-wave tool strengthen Ki(vital energy) in the middle elixir-field by the multi-method of the recognition-stimulation, micro-vibration, micro-current. The mystical pillow being composed of thirty two herbs strengthen mental activity in the upper elixir-field. The three methods are the synthetic, practical, familiar health tools for silver longevity.

Study on the wave resonance-stimultion and receptionfor the BIO-KI (생체 기에 대한 피동공명적인 연구)

  • Ryu Gyeong Ho;Kim Gyeong Cheol;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.263-274
    • /
    • 2003
  • The present condition of study on the wave-resonance for the bio-KI is observed. And the probroms of reception attendent on the stimulation of wave is observed centering around the sensory organ. The results is as follows: In the wave-resonant stand point, the tendency of studying on KI is showed in the several field all over the world. Because it is originated radionics, the wave-resonant tools of MRA insistenting minute-magnetism-resonance-apparatus need the more severe data in the side of electric circuit. The wave resonance apparatus according to the frequency occurance transmits low-frequency's vibration ratio to the electric stimulating aspect. The wave-water is considered on the application of wave-resonance transcription on the water, and needs the comprehension of torsion-field level. The wave-stimulation of the bio-KI and the reception of the sensory-organ is observed the connection of the sensory-organ and it's corresponding wave. The informations recorded in the wave are distinguished patternly. And the several shaping waves transmit the informations each other through the resonnance. The wave theory is explained the LEE(理) as the wave-pattern and the KI(氣) as the revelation of the patterned-wave in the LEE-KI theory(理氣論), moreover the SHIN(神) as the information of the wave-pattern and the KI as the energy of the wave and the JEUNG(精) as the material of the wave in the JEUNG-KI-SHIN theory(精氣神論). In this point, the study on the wave-resonance of bio-KI is thought that it is significantly in the study method for oriental medicine. The sum of the wave makes the moving body and forms the universe. It means that the several wave patterns gather and form new field. The pattern is a kind of the information and the information is not materially. The information of wave-pattern is the arrangement and the combination of the material source.

Effects of the Neck Stabilization Exercises with Vibratory Stimulation on the Neck Disability Index and Thickness of Deep Neck Flexor in Neck Pain Patient

  • Kim, Se-Hun;Park, Jang-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.5
    • /
    • pp.265-270
    • /
    • 2017
  • Purpose: This study examined the effects of neck stabilization exercises with vibratory stimulation on the neck disability index and thickness of the deep neck flexor. Methods: Thirty subjects (control group=15, experimental group=15) with mild neck pain were enrolled in the study. The control group underwent craniocervical flexion exercise (control group, CG) and the experimental group was given craniocervical flexion exercise with vibratory stimulus (experimental group, EG) (3 sets, 3 times per week for 6 weeks). To examine the effects of exercise, the subjects were evaluated using the neck disability index (NDI), the thickness of the deep neck flexor muscle, and muscle strength. An independent and paired t-test were used to compare the effects of the exercise between the groups. Results: The NDI score of the two groups increased significantly after 6 weeks of treatment (p<0.001) and there was a significant difference between the EG group at 3 weeks (p<0.05) and 6 weeks (p<0.01). The thickness of the deep neck flexor in the CG group increased significantly after 6 weeks of treatment in all pressure stages (p<0.001). The EG group showed a significant increase after 3 and 6 weeks of treatment in all pressure stage (p<0.001), and 22 mmHg, a significant difference between 3 and 6 weeks (p<0.05) and among 24, 28, and 30 mmHg at 6 weeks (p<0.05). The maximum muscle strength of the deep neck flexion muscles increased significantly in the two groups after 6 weeks of treatment (p<0.001) and there was significant difference between the EG group at 6 weeks (p<0.01). Conclusion: Craniocervical flexion exercise with vibratory stimulus decreases the NDI, and increases the thickness of the deep neck flexor and maximum muscle strength of the deep neck flexion muscles in patients with mild neck pain.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

Effects of Vibration Stimulation Therapy on Neglect of Stroke Patients (진동감각 자극치료가 뇌졸중 환자의 편측무시에 미치는 영향)

  • Jeon, So-Hyun
    • Journal of Society of Occupational Therapy for the Aged and Dementia
    • /
    • v.12 no.2
    • /
    • pp.87-95
    • /
    • 2018
  • Objective : Vibration stimulators are easier to obtain in clinical settings than other treatment tools, and it is advantageous that the arm activation training can be performed passively. Despite the following advantages, recent studies on vibration sense have not been activated yet. The purpose of this study was to investigate the effect of vibration sensation on the hands of the affected upper limb on unilateral reduction of stroke patients. Method : Patients with unilateral neglect due to stroke were enrolled in this study for about 3 weeks from October 19, 2018 to November 7, The research design used ABA design among the single-subject experimental research design, and a total of 18 circuits (4 baseline, 6 intervention, 3 baseline regression) were performed once a day on weekdays Respectively. MMES-K was used to select the subjects. Line bisection test (LBT), Albert's test and Star Cancellation Test (SCT) were used as unilateral neglect test. For the analysis, the baseline and intervention period measurements were visually analyzed using graphs and mean values were used. Result : All three evaluations showed that the number of errors missed during the training period was lower than the baseline period, and this decrease remained after training. The error was reduced by an average of $2{\pm}1.2$ omissions and an average omissions of $0.6{\pm}0.5$ omitting an average of $4.5{\pm}1$ omissions in the line break test. As a result of the Albert test, the average error decreased by $22.5{\pm}1.9$ omissions and $8{\pm}7.3$ omissions and $0.3{\pm}0.5$ omissions, respectively. In the star clearance test, the average error decreased from $26{\pm}4.6$ to $21.8{\pm}1.7$ and $20{\pm}0$, respectively. Conclusion : In this study, vibrotactile stimulation therapy showed a continuous effect on improving unilateral neglect. Based on these findings, further research should be conducted in order to improve objectivity in future studies. Further research on various arbitration methods that maximize the effect of intervention will be needed.

Test Method for Guided Missile Cable ESS(Environmental Stress Screening) Based on MIL-HDBK-344A (MIL-HDBK-344A 기반의 유도탄 내부 케이블 ESS 시험 방안)

  • Lee, Dae-Hyun;Lee, Jung-Min;Oh, TaeckKeun;Lee, Hong-Beom;Jung, JunYoung
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.5
    • /
    • pp.313-319
    • /
    • 2021
  • In this paper, the ESS test based on the MIL-HDBK-344A is introduced, and the purpose of the ESS test of the guided missile internal cable, and the specification and test method are confirmed. The ESS test configuration consists of environmental stimulation of temperature circulation and random vibration. Based on the procedure in the handbook, the ESS test specification setting and test configuration of the guided missile internal cable are presented, and the jig for the ESS test of the guided missile internal cable for the vibration test was produced. The probability of detecting a defect determined through the screening strength(SS) was set to match the reliability of a one-time guided missile, and also introduced the inspection method and considerations for the cable inside the guided missile during the ESS test.