• Title/Summary/Keyword: Vibration Measuring

Search Result 822, Processing Time 0.036 seconds

Reports on the Meetings of ISO/TC108 Mechanical Vibration and Shock and ISO/TC108/SC3 Use and Calibration of Shock Measuring Instruments Tokyo, Nov. 4-8, 2002

  • Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.468-474
    • /
    • 2003
  • 1. Schedule for the meetings of ISO/TC108 Mechanical vibration and shock and ISO/TC108/SC3 Use and calibration of shock measuring instruments 2. Minutes for the seventh meeting of ISO/TC108/WG23 Mechanical vibration and shock - Resilient mounting systems - Information for the application of source and receiver isolation (omitted)

  • PDF

Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400 (APR1400 상부안내구조물 집합체 구조해석 및 측정위치)

  • Ko, Do-Young;Kim, Kyu-Hyung;Kim, Sung-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.306-311
    • /
    • 2012
  • A reactor vessel internals comprehensive vibration assessment program (RVI CVAP) of an advanced power reactor 1400 (APR1400) is being performed as a non-prototype category-2 type of reactor based on the US Nuclear Regulatory Commission Regulatory Guide (NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure (UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly results show that meet the specified integrity levels of the design acceptance criteria. Also, the measuring locations are set by the analysis results of the UGS assembly and selection criteria of measuring locations prior to this study. These analysis results and measuring locations will be used as fundamental materials to design a measurement system for the APR1400 RVI CVAP.

  • PDF

Development of Selection Criteria of Measuring Places for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400 (APR1400 원자로내부구조물 종합진동평가 측정위치 선정기준 개발)

  • Ko, Do-Young;Kim, Kyu-Hyung;Kim, Sung-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.821-826
    • /
    • 2011
  • A basic concept for selection criteria of measuring places of RVI CVAP is to determine measuring places and sensors based on the results of the hydraulic and structural analysis for RVI CVAP in APR1400. In addition, there is the important selection criteria to determine measuring places for measurement of RVI CVAP ; the first is to choose measuring places according to U.S. NRC R.G. 1.20, the second is to select measuring places by RVI design review, the third is to option on the basis of measurement results of SYSTEM 80, the forth is to decide using review results on a design change of a reactor and the last is to determine using the review on the possibility of installation/removal of sensors and structures for the measurement. We developed selection criteria of measuring places for RVI CVAP in APR1400 and this will be directly applied to the measurement program for RVI CVAP.

  • PDF

A study on the control of vibration caused by a blasting (발파진동 저감방법에 관한 연구)

  • 석철기
    • Explosives and Blasting
    • /
    • v.16 no.2
    • /
    • pp.34-46
    • /
    • 1998
  • We developed a method to control vibration from some blasting points. This method uses a correlation of vibration waves to decide the most effective delay time to control vibration by interfering vibration waves with each other. We applied this method to the small blasting using mortar blocks and examined the effect on controlling vibration. As the result of the examinations, the maximum vibration velocity by this method caused by five detonators blasting in row of five holes became smaller than that by a detonator blasting in the nearest hole from the measuring point. And the velocity was about one fifth of that of maximum condition in which vibration waves caused by the five detonators arrivved at the same time to the measuring point.

  • PDF

Ambient Vibration Measurement of Buildings Horizontal Vibration Using a Mobile Phone Application (휴대폰 앱을 이용한 건물 수평진동의 상시진동계측)

  • Moon, Sang-Hyouen;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.3
    • /
    • pp.77-83
    • /
    • 2015
  • The cases of conducting the vibration measurement using the mobile phone with regard to the building's horizontal vibration are very rare in Korea and foreign countries. Therefore, this study analyzed the horizontal vibration nature of the building using the mobile phone targeting 5 tall buildings, and reviewed about the applicability of the mobile phone vibration measuring instrument through the comparison/verification with the data of the existing vibration measuring instrument. The peak of the measured time series waveform was measured clearly and it showed a similar value to the existing natural frequency.

Estimation of Uncertainty in Vibration Measurement of Shipboard Equipment (함정탑재장비 진동 측정불확도 추정)

  • Park, Sungho;Lee, KyungHyun;Han, HyungSuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.509-516
    • /
    • 2014
  • This paper proposes estimation model of uncertainty in vibration measurement of shipboard equipment and analyzes the result of uncertainty estimation. Vibration of shipboard equipments affects underwater radiated noise that is important performance related to stealth of the naval vessel. Acceptance testing for shipboard equipment is required to guarantee the stealth performance of naval vessel. In measuring, detailed uncertainty estimation is essential to improve measuring reliability. Acceptance testing result of structure-borne noise and vibration is used to analyze uncertainty in vibration measurement of shipboard equipment.

The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area (도심지 발파공사장의 발파진동 특성)

  • 이연수;장서일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area (도심지 발파공사장의 발파진동 특성)

  • 장서일;이연수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.

Selection of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400 (APR1400 원자로 내부구조물 종합진동평가 측정센서 선정)

  • Ko, Do-Young;Lee, Jae-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.433-438
    • /
    • 2010
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. Nuclear Regulatory Commission Regulatory Guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement, and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors. We analyzed RVI design data of Palo Verde nuclear generating station(U.S.) and Yonggwang nuclear generating station(Korea) and investigated measuring sensors used in both of them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected the most suitable sensors for RVI CVAP in Advanced Power Reactor 1400(APR1400).

  • PDF

Monitoring of Machining Process by Measuring Vibration of Cutting Forces (절삭력 진동 측정에 의한 가공공정 모니터링)

  • Jeon, Jae Hyeon;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1106-1112
    • /
    • 2012
  • This paper deal with a technique for monitoring machining conditions by measuring the vibration of cutting forces at milling machining. The vibrations of cutting forces in milling process were measured and analyzed to be related with processing parameters. The magnitude of cutting force is linearly proportional to the feed rate and cutting depth, and frequency of cutting force is linearly proportional to the rotating speed. Wired and wireless communication methods were applied in transmitting the measured vibration signals and the two methods were compared. The magnitude of the vibration signals transmitted by the wireless communication method was similar to that transmitted by the wired communication method.