• 제목/요약/키워드: Vibration Intensity

검색결과 474건 처리시간 0.022초

구조 변경을 통한 공조용 압축기의 소음저감 (Noise Reduce in the Rotary Compressor for air-conditioner using Structural Modification)

  • 김진수;이승목;하종훈;이장우;하삼철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.556-563
    • /
    • 2010
  • The main noise source of the rotary compressor for air conditioner was analyzed by using the measurement of sound intensity, modal analysis and operational deflection shape(ODS) analysis. In this study, the key noise source of rotary compressor was an accumulator, and noise was sharply increased due to the accumulator's resonance which has a big contribution to the noise. To reduce the excessive noise generated from accumulator, structural modification through ODS analysis were applied. Its validation was conducted by the measurement of noise and vibration on the accumulator's surface. The total noise was significantly reduced by 4.2dB(A).

  • PDF

MSC/NASTRAN 및 PCL을 이용한 구조물 내의 진동 파워 흐름 해석 기법 (A Technique for Calculations of Power Flow in Structures Using MSC/NASTRAN and PCL)

  • 홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제11권8호
    • /
    • pp.303-313
    • /
    • 2001
  • The identification of power flow in dynamically loaded structures Is essential in the analysis of structure-borne noise. However there are no general purpose tools to estimate powers flow. To make matters worse. It is very difficult to measure it. The power flow can be formulated in terms of balance forces(ELFORCE) at each element and velocities at the associated node obtained with MSC/NASTHAN. In this paper the procedure which is consist of the computations of the balance forces of al1 elements and the velocities at all nodes using MSC/NASTRAN. The calculations of the power f1ow at each element using PCL(PATRAN Command Language) and the Preparation of post -processes is set UP.

  • PDF

실험적 방법을 통한 에어컨 실내기의 소음원 검출에 관한 연구 (A Study on Noise Identification of Indoor Air-conditioner Using Experimental Methods)

  • 이성진;오재응;이정윤;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.87-87
    • /
    • 2004
  • An air-conditioner has various noise sources such as a fan noise, a motor noise, and a vibration induced noise. To reduce these noise effectively, noise sources must be identified. Especially in this paper, the structure borne sound radiated from the motor bracket of the indoor air-conditioner is considered. To do this, the operational deflection shape, which is used for understanding of the behavior of the motor bracket at a particular frequency, is obtained and compared with the sound intensity, which is used for the noise identification. Through this study, the noise sources of indoor air-conditioner are defined and the effective noise reduction method is proposed.

  • PDF

고속 CD-ROM Drive의 구조 및 음장 해석 (Structural and Sound Field Analysis of the High Speed CD-ROM Disk Drive)

  • 임웅섭;차성운;이재승;문용락
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.210-215
    • /
    • 2001
  • CD-ROM Drives Rotating high speed as 10000 rpm cause serious noise and vibration problems. At the high speed, dominant noise is Air Borne Noise produced from high-speed airflow and Structure Borne Noise produced from structural vibration. In this research, vibration and sound characteristics in CD-ROM Drive were studied by the use of experimental analysis and computational simulation. Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of CD-ROM drive. And Computational simulation using SYSNOISE is conducted for describing the noise behavior.

  • PDF

Vibration Power Flow Analysis of Submarine-shaped Structures using Developed Software

  • Seo, Seong-Hoon;Hong, Suk-Yoon
    • Journal of Ship and Ocean Technology
    • /
    • 제6권2호
    • /
    • pp.1-11
    • /
    • 2002
  • For the analysis of vibrational energy density and intensity of partitioned complex system structures in medium-to-high frequency ranges, A software based on the Power Flow Analysis(PFA) has been developed for the plate elements. The flexural, longitudinal and shear waves in plates are formulated and the joint element equations for multi-coupled plates are fully developed. Also, the wave transmission approach has been introduced to cover the energy transmission and reflection at the joint plate elements. To confirm the validity of the developed PFA software, the submarine-shaped complex structures are used for the analysis of vibration intensity and energy density.

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

콘크리트 강도에 따른 바닥판 수직진동에 대한 적정 두께 제안 (The Adequate Slab Thickness Satisfied with the Vertical Floor Vibration Criteria for Several Concrete Compressive Strength)

  • 남상욱;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.659-662
    • /
    • 2003
  • Recently, the floor thickness in residence may not be satisfied with the floor vibration criteria although the thickness is evaluated by the serviceability requirements in current design provisions. Thus it is necessary to develop the procedure to determine slab thickness satisfied with the floor vibration criteria. In this study, We proposed the methods to determine the slab thickness satisfied with the vertical floor vibration criteria for several concrete compressive strength of flat plate floor systems. For this purpose Monte Carlo simulation procedure was adopted and both randomness inherent in young modulus of concrete and heel drop intensity were accounted.

  • PDF

연성된 쉘 구조물의 진동 파워흐름해석 (Vibration Power Flow Analysis of Coupled Shell Structures)

  • Kim, Il-Hwan;Hong, Suk-Yoon;Park, Do-Hyun;Kil, Hyun-Gwon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.352.2-352
    • /
    • 2002
  • In this paper, Power Flow Analysis (PFA) method has been applied to the prediction of vibration energy density and intensity of coupled shell structures in the medium-to-high frequency ranges. To consider the wave transformation at joint between shell elements, power transmission and reflection coefficients are investigated for various joint angles, and here Donnell-Mushtari thin shell theory has been used. (omitted)

  • PDF

표면근전도를 이용한 진동운동기의 근수축 효과에 관한 연구 (The Study of Muscle Contraction Effect of Vibration Exercise Device Using Surface Electromyography)

  • 백승국;임영태
    • 한국운동역학회지
    • /
    • 제16권2호
    • /
    • pp.55-63
    • /
    • 2006
  • The purpose of this study was to investigate the effects of vibration exercise using surface electromyography. Seven male collegiate wrestlers were participated in this study. Each subject stood on the platform and the vibration was induced for 1min. WEMG8 EMG system was used to record muscle activity from Vastus lateralis, Biceps Femoris, Tibialis Anterior, and Gastrocnemius. The EMG data were sampled for 30 sec. during non-vibration and vibration half squat position, respectively. The raw data were band pass filtered to remove noise and full wave rectified Paired sample t-test were performed to see the differences of maximum and average EMG between non-vibration and vibration trials. The results indicated that vibration produced much more muscle contraction than that of non-vibration trial for all selected muscles even though the significant difference was found only from Biceps Femoris. This phenomenon was due to the individual differences so care must be taken to evaluate vibration intensity and position before personal training.

복소음향 인텐시티법을 이용한 소음원검출의 시뮬레이션 및 실차응용 (Computer Simulation for Noise Source Identification and Application to Vehicle Using Complex Acoustic Intensity Method)

  • 오재웅;김상헌;안지훈
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.171-171
    • /
    • 1997
  • Sound intensity distributions and energy flow in the near field of dipole source system and flat plate were investigated. First, the effectiveness of complex acoustic intensity was proved by using mathmatical and experimental methods in order to indentify noise sources and transmission paths of dipole field which is effected by the presence of neighbouring coherent sources. Next, analytical complex acoustic intensity method was discussed and the characteristics and energy flow of sound induced from the plate are clarified. The velocity of plate obtained from Finite Element Method was used for calculation of complex acoustic intensity in the near field. Finally experimental complex acoustic intensity method was applied to a passenger car. It can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for the identification and the reduction of vibration and noise.