• Title/Summary/Keyword: Vibration Criterion

Search Result 200, Processing Time 0.022 seconds

A Study on the Control of the Floor Vibration in a Research Building (연구소(硏究所) 건물(建物)의 슬래브 진동(振動) 성능개선(性能改善) 연구(硏究))

  • Baik, In-Whee;Kang, Ho-Sub;Sohn, Young-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • A vibration in the building occurs by influences of the facility equipment and the structural system. As the building recently becomes higher and bigger, the vibration in the floor slab is issued. Specially, the vibration with $4{\sim}8Hz$ frequency is harder to control than any other range of frequency. This vibration easily affects human sensibility and often makes the resonance phenomenon by corresponding with the floor slab's natural frequency when people and heavy equipments move. Moreover, the permission regulations for the vibration of the building are established by building's purposes. However, it is not subdivided in detail and sometimes ambiguous to each client. Even though the vibration could cause negative influences in a research building, there is not the vibration criterion for a research building. Therefore, it is necessary to set up its own vibration criterion with the client before building and to keep checking this vibration criterion under the construction. This study proposes the reasonable control methods and the vibration criterion for floor slab's vibration which are adapted to the R4-project. The R4-project is a research building and a high-rise building also. Accordingly, this study could help to the next similar project in the design and the construction phase.

A Review on the Problem of Korean Blast Damage Criterion (우리나라 발파진동 허용기준의 문제점에 대한 고찰)

  • 두준기;류창하
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.85-95
    • /
    • 2004
  • A damage criterion by blast vibration & noise has to be established through a engineering view point. Though a blast vibration has effects on human and structure, they have experienced a different damage. Thus, a damage criterion for structure needs to get a peculiar criterion which are different from one for human. At present, blast damage criterions authorized by government are Vibration & Noise Act made by Ministry of Environment and blast damage criterion of specifications for tunnel made by Ministry of Construction & Transportation. Vibration & Noise Act is based on the response of human, and while it has some application problems, it turns out to be partly rational. But, blast damage criterion of specifications for tunnel has unreasonable guidelines. In this article, its problems are reviewed and a alternative blast damage criterion is suggested.

Dynamic Characteristics of Buried Pipeline under Vibration Velocity of Vehicle Loads (도로 하부 통과 배관의 주행 하중 속도에 따른 진동 특성)

  • Won, Jong-Hwa;Sun, Jin-Sun;Yoo, Han-Kyu;Kim, Moon-Kyum
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Vibration velocity induced by earthquakes or external vibration sources is one of the integrity assessment indexes, and is also a representative value used to describe the amount of vibration because it is based on a proportional relationship with the damage scale. In this study, the vibration velocity criterion for structures is first examined. Then, based on the velocity criterion, an integrity assessment is performed. Burial condition is set up based on the "Highway and Local Road Design Criteria" with API 5L Gr. X65 pipeline(D=762 mm). The FE model considers DB-24 vehicle load as a time function with a varying velocity in the range of $20{\sim}160\;km/h$. Maximum vibration velocity occurs at v=80 km/h and decreases after v=80 km/h. The maximum vibration velocity of buried pipeline by DB-24 loads is about 0.034 cm/s. The velocity that occurs is in the range of allowable values for each vibration velocity criterion. The wave propagation velocity was identified based on attenuation law and the minimum value appears at vehicle velocity 80 km/h that has maximum vibration velocity.

  • PDF

Suggestion of Vibration Criteria for Fresh Concrete Considering Early Strength Increase (Fresh 콘크리트의 초기 강도 증가를 고려한 진동규준치 제안)

  • Park, Sun-Joon;Park, Yeon-Soo;Kang, Sung-Hoo;Kim, Hong-Ki;Kim, Eung-Rok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.453-460
    • /
    • 2002
  • In this paper, vibration criteria for fresh concrete are suggested considering relationship of strength and ages of concrete. Vibration criteria of fresh concrete subjected to construction vibration are not to be certain in abroad countries without question within a country. Before 12 hours cured, vibration criterion is suggested 0.25 cm/s. Used 4.0 cm/s by vibration criterion after 28 days. And the interval extent used relation with strength and ages of concrete. Vibration criteria proposed in this paper are thought may satisfy properties of fresh concrete as well as generally used those in domestic. Also, the actual ground vibrations due to pile driving have been measured, and data are analyze using the nitration equation applying to reliability index.

Vibration-based damage alarming criteria for wind turbine towers

  • Nguyen, Cong-Uy;Huynh, Thanh-Canh;Dang, Ngoc-Loi;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.3
    • /
    • pp.221-236
    • /
    • 2017
  • In this study, the feasibility of vibration-based damage alarming algorithms are numerically evaluated for wind turbine tower structures which are subjected to harmonic force excitation. Firstly, the algorithm of vibration-based damage alarming for the wind turbine tower (WTT) is visited. The natural frequency change, modal assurance criterion (MAC) and frequency-response-ratio assurance criterion (FRRAC) are utilized to recognize changes in dynamic characteristics due to a structural damage. Secondly, a finite element model based on a real wind turbine tower is established in a structural analysis program, Midas FEA. The harmonic force is applied at the rotor level as presence of excitation. Several structural damage scenarios are numerically simulated in segmental joints of the wind turbine model. Finally, the natural frequency change, MAC and FRRAC algorithm are employed to identify the structural damage occurred in the finite element model. The results show that these criteria could be used as promising damage existence indicators for the damage alarming in wind turbine supporting structures.

Assessment of Anti-vibration Gloves for Reduction of Hand-transmitted Vibration Exposure (수전달 진동 피폭 저감을 위한 방진 장갑의 성능 평가)

  • Choi, Seok Hyun;Hong, Seok In;Jang, Han Kee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing, evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm. Whole procedure of ISO 10819:1996 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of 9 anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of the corrected vibration transmissibility were also calculated. All tested gloves fulfilled criterion for M-spectrum($\overline{TR_M}$<1.0), but one glove fulfilled criterion for H-spectrum($\overline{TR_H}$<6.0),

A Theoretical Study on a Weight per Delay (지발당 장약량에 대한 이론적 연구)

  • Kim, Jong-In;Kang, Choo-Won;Kim, Jea-Wong
    • Explosives and Blasting
    • /
    • v.24 no.2
    • /
    • pp.33-39
    • /
    • 2006
  • The blasting vibration prediction in Korea is mainly carried out by the scaled distance method. The delay interval of the scaled distance method is generally considered to be 8ms, where the effect of vibration between adjacent holes is not included. In this study, the origin and issues of 8ms criterion are reviewed from literatures and Langefors' 2.5T criterion is applied to evaluate the applicabilities of 8ms, 17ms and 25ms intervals in which a vibration does not affect an adjacent hole.

A Case on Excavation Plan and Design of Adjacent Railroad Tunnel (근접 철도터널의 굴착계획 및 설계 사례)

  • 김선홍;정동호;석진호;정건웅;서성호
    • Explosives and Blasting
    • /
    • v.20 no.3
    • /
    • pp.59-71
    • /
    • 2002
  • The points of this design case are the planning and excavation method of a new double-tracked railroad tunnel which is approx. 11∼22 meters apart from existing single-tracked railroad tunnel. For the optimum excavation method some needs are required in design stage, such as the reduction of noise and vibration, public resentment, damage of buildings and construction costs. Hence the estimation and application of allowable noise and vibration criterion is important. The ground coefficient (K, n) of this site is determined by field trial blasting. The excavation method is chosen to satisfy the allowable noise and vibration criterion. In addition, in order to ensure the stability of existing single-tracked railroad tunnel, the instrumentation of maintenance level is accompanied during the construction stage. As a result of this design condition, central diaphragm excavation with line drilling and pre-large hole boring blasting is applied to the area within 15 meters apart from existing tunnel. And above 15 meters apart, pre-large hole boring blasting is designed.

Reproduction of vibration patterns of elastic structures by block-wise modal expansion method (BMEM)

  • Jung, B.K.;Cho, J.R.;Jeong, W.B.
    • Smart Structures and Systems
    • /
    • v.18 no.4
    • /
    • pp.819-837
    • /
    • 2016
  • The quality of vibration pattern reproduction of elastic structures by the modal expansion method is influenced by the modal expansion method and the sensor placement as well as the accuracy of measured natural modes and the total number of vibration sensors. In this context, this paper presents an improved numerical method for reproducing the vibration patterns by introducing a block-wise modal expansion method (BMEM), together with the genetic algorithm (GA). For a given number of vibration sensors, the sensor positions are determined by an evolutionary optimization using GA and the modal assurance criterion (MAC). Meanwhile, for the proposed block-wise modal expansion, a whole frequency range of interest is divided into several overlapped frequency blocks and the vibration field reproduction is made block by block with different natural modes and different modal participation factors. A hollow cylindrical tank is taken to illustrate the proposed improved modal expansion method. Through the numerical experiments, the proposed method is compared with several conventional methods to justify that the proposed method provides the improved results.

Evaluation of Vibration Reduction Performance of Operator Seat for Agricultural Tractors (트랙터 운전석의 진동 감쇠 성능 평가)

  • Shin, Chang-Seop;Kim, Kyeong-Uk
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Six models of operator seat supplied to local tractor manufacturers were tested in the laboratory in accordance with ISO 5007 and 78/764/EEC. No models out of the six met the allowable damping and transmissibility performance criteria of both ISO 5007 and 78/764/EEC. From the ISO criterion standpoint, one model failed in damping performance and 4 models in isolation performance. From the 78/764/EEC criterion standpoint, 4 models failed in damping performance and 4 models in isolation performance. However none of them failed in all of the criteria, either. Each model met the one acceptance criterion but failed in another. This indicated that operator seat must be improved to meet the current ISO 5007 or 78/764/EEC and the exposure limit value that will be enforced in EU tractor market from 2014 by EU Directive 2002/44 EC.