• 제목/요약/키워드: Vertical-axis tidal current turbine

검색결과 17건 처리시간 0.018초

CFD를 이용한 수직축 터빈 설계 및 유동특성 분석 (Vertical Axis Tidal Turbine Design and CFD hydrodynamic Analysis)

  • 조철희;고광오;이준호;노유호;이강희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.159.1-159.1
    • /
    • 2011
  • Due to the global warming, the need to secure the alternative resources has become more important worldwide. Having very strong current on the west coast with up to 10 m tidal range, there are many suitable sites for the application of TCP(Tidal current power) in Korea. Not only from the current produced from the high tidal range, but also it can be widely applied to the offshore jetties and piers. The VAT(Vertical axis turbine) system could be very effective tidal device to extract the energies from the attacking flow to the structures. For the relatively slow current speed, the VAT system could be more effective application than HAT(Horizontal axis turbine) device. The performance of VAT can be evaluated by various parameters including number of blades, shape, sectional size, diameters and etc. The paper introduces the multi-layer vertical axis tidal current power system with savonius turbine. The turbine was designed with consideration of optimal blade numbers and the performance was simulated by CFD analysis.

  • PDF

항력식 조류발전 터빈의 최적 형상 설계 및 유동 수치해석을 통한 성능 평가 (Design and Performance Evaluation of the Savonius Tidal Current Turbine)

  • 조철희;고광오;이준호;이강희
    • 신재생에너지
    • /
    • 제8권2호
    • /
    • pp.6-13
    • /
    • 2012
  • Due to global warming, the need to secure an alternative resource has become more important nationally. Having very strong current on the west coast with up to 10 m tidal range, there are many suitable site for the application of TCP (Tidal Current Power) in Korea. On the south west regions between many islands that create strong current in the narrow channels. The rotor is one of the essential components which can convert tidal current energy into rotational energy to generate electricity. The design optimization of rotor is very important to maximize the power production. The performance of rotor can be determined by various parameters including number of blades, shape, sectional size, diameters and etc. This paper introduces the multi-layer vertical axis tidal current power system which can be applied to offshore jetties and piers effectively. Various cases of VAT turbine were designed. Specifically, the number of blades and turbine shape are changed in several cases. Also, performance analysis was carried out by CFD.

사보니우스형 조류발전 터빈의 설계 및 회류수조 실험을 통한 성능평가 (Design and Performance Test of Savonius Tidal Current Turbine with CWC)

  • 조철희;이준호;노유호;고광오;이강희
    • 한국해양공학회지
    • /
    • 제26권4호
    • /
    • pp.37-41
    • /
    • 2012
  • Due to global warming, the need to secure alternative resources has become more important nationally. Because of the very strong current on the west coast, with a tidal range of up to 10 m, there are many suitable sites for the application of TCP (tidal current power) in Korea. In the southwest region, a strong current is created in the narrow channels between the numerous islands. A rotor is an essential component that can convert tidal current energy into rotational energy to generate electricity. The design optimization of a rotor is very important to maximize the power production. The performance of a rotor can be determined using various parameters, including the number of blades, shape, sectional size, diameter, etc. There are many offshore jetties and piers with high current velocities. Thus, a VAT (vertical axis turbine) system, which can generate power regardless of flow direction changes, could be effectively applied to cylindrical structures. A VAT system could give an advantage to a caisson-type breakwater because it allows water to circulate well. This paper introduces a multi-layer vertical axis tidal current power system. A Savonius turbine was designed, and a performance analysis was carried out using CFD. A physical model was also demonstrated in CWC, and the results are compared with CFD.

조류발전용 수직축 터빈 주위의 비정상 유동 수치해석 (A Numerical Study of Unsteady Flow around a Vertical Axis Turbine for Tidal Current Energy Conversion)

  • 정현주;이신형;송무석;현범수
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제12권1호
    • /
    • pp.9-14
    • /
    • 2009
  • 2차원 비정상의 RANS 방정식을 이용하여 피치가 고정된 3개 혹은 4개의 날개(hydrofoil)를 가지는 조류발전용 수직축 터빈주위의 비정상 유동장 해석을 수행하였다. 상용수치해석코드인 Fluent를 이용하여, 균일류에 놓인 $NACA65_3$-018날개에 대하여 받음각(angle of attack)의 변화를 주며 계산되는 유체력을 실험값과 비교하였고, 이를 바탕으로 대표적인 수직축 조류발전 터빈의 특성을 2차원적으로 고찰하였다. 사용된 수치해법은 대상 유동을 효과적으로 모사할 수 있음을 확인 하였고, 터빈의 최적 효율은 날개수 및 유속 대비 회전수 등의 적절한 조합으로 실현 될 수 있음을 파악하였다.

  • PDF

조류발전용 수직축 터빈의 공진 회피 설계를 위한 프로그램 개발 (Development of Vibration Analysis Program for Anti-resonance Design of Vertical-axis Tidal Current Turbine)

  • 배재한;성혜민;조대승;김재호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.336-341
    • /
    • 2012
  • The vertical-axis tidal current turbine (VAT) consisting of blades, struts to support blades, shaft, generator and so forth requires anti-resonance design against fluid fluctuation forces generated on blades to ensure its stable operation. In this study, a free vibration analysis program based on the finite element method is developed for efficient anti-resonance design of VAT in the preliminary design stage. In the finite element modeling, the VAT structure components are regarded as beam elements. Added masses due to the fluid and structure interaction of VAT evaluated by empirical formulas are considered as lumped mass elements. In addition, input parameters required for the analysis can be automatically prepared from the principal dimensions of VAT to make anti-resonance design more convenient. The validity of applied methods is verified by the comparison of the numerical results obtained from MSC/Nastran and the developed program for two VAT models.

  • PDF

수직축 조류 터빈 발전효율 평가를 위한 유동-터빈 연동 CFD 해석 (II) (Flow-Turbine Interaction CFD Analysis for Performance Evaluation of Vertical Axis Tidal Current Turbines (II))

  • 이진학;오상호;박진순;이광수;이상열
    • 한국해양공학회지
    • /
    • 제27권3호
    • /
    • pp.73-78
    • /
    • 2013
  • CFD (computational fluid dynamics) analyses that considered the dynamic interaction effects between the flow and a turbine were performed to evaluate the power output characteristics of two representative vertical-axis tidal-current turbines: an H-type Darrieus turbine and Gorlov helical turbine (GHT). For this purpose, a commercial CFD code, Star-CCM+, was utilized, and the power output characteristic were investigated in relation to the scale ratio using the relation between the Reynolds number and the lift-to-drag ratio. It was found that the power coefficients were significantly reduced when the scaled model turbine was used, especially when the Reynolds number was lower than $10^5$. The power output characteristics of GHT in relation to the twisting angle were also investigated using a three-dimensional CFD analysis, and it was found that the power coefficient was maximized for the case of a Darrieus turbine, i.e., a twisting angle of $0^{\circ}$, and the torque pulsation ratio was minimized when the blade covered $360^{\circ}$ for the case of a turbine with a twisting angle of $120^{\circ}$.

수평축 조류발전 터빈 설계 및 후류 특성 분석 (Design of Horizontal Axis Tidal Current Power Turbine with Wake Analysis)

  • 조철희;김도엽;이강희;노유호;김국현
    • 신재생에너지
    • /
    • 제7권3호
    • /
    • pp.92-100
    • /
    • 2011
  • With the increased demand of clean energy and global warming measures, the renewable energy development has been increased recently. The TCP (Tidal Current Power) is one of the ocean renewable energy sources. Having the high tidal energy source in Korea, there are many potential TCP sites with strong current speed. The rotor, which initially converts the energy, is a very important component because it affects the efficiency of the entire system. The rotor performance is determined by various design parameters including number of blades, shape, sectional size, diameters and etc. However, the interactions between devices also contribute significantly to the energy production. The rotor performance considering the interaction needs to be investigated to predict the exact power in the farm. This paper introduces the optimum design of TCP turbine and the performance of devices considering the interference between rotors.

수직축 조류 터빈 발전효율 평가를 위한 유동-터빈 연동 CFD 해석 (I) (Flow-Turbine Interaction CFD Analysis for Performance Evaluation of Vertical Axis Tidal Current Turbines (I))

  • 이진학;오상호;박진순;이광수;이상열
    • 한국해양공학회지
    • /
    • 제27권3호
    • /
    • pp.67-72
    • /
    • 2013
  • In this study, numerical analyses that considered the dynamic interaction effects between the flow and a turbine were carried out to investigate the power output performance of an H-type Darrieus turbine rotor, which is one of the representative lifting-type vertical-axis tidal-current turbines. For this purpose, a commercial CFD code, Star-CCM+, was utilized for an example three-bladed turbine with a rotor diameter of 3.5 m, a solidity of 0.13, and the blade shape of an NACA0020 airfoil, and the optimal tip speed ratio (TSR) and corresponding maximum power coefficient were evaluated through exhaustive simulations with different sets of flow speed and external torque conditions. The optimal TSR and maximum power coefficient were found to be approximately 1.84 and 48%, respectively. The torque and angular velocity pulsations were also investigated, and it was found that the pulsation ratios for the torque and angular velocity were gradually increased and decreased with an increase in TSR, respectively.

500kW 조류력 발전장치 개발 및 울돌목 실증시험 (Development of 500kW Tidal Current Energy Converter and Uldolmok Field Test)

  • 심우승;최익흥;이규찬;김해욱;배종국;민계식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.159.2-159.2
    • /
    • 2011
  • Hyundai Heavy Industries has developed a tidal current energy converter utilizing the accumulated technology as the world largest constructor for ship and offshore structures. The model has two sets of turbines in both ends in order to utilize the bi-directional current flows in flood and ebb tide. The torque produced by turbine in tidal current is directly delivered to generator along the horizontal axis, in which the turbine, gear, generator, gear and turbine are connected successively. The manufactured model for field test has the turbine diameter of 5 meters to produce the maximum power of 500kW at maximum current speed of 5m/s. The technical verification of tidal power converter was performed by means of small scale model test in towing tank as well as field test at the Strait of Uldolmok located in Jindo of Jeollanamdo province. Field test was performed by mounting the tidal current converter on the SEP(Self Elevating Platform) which could lower the 4 vertical legs on the seabed and could elevate platform over the water surface using the hydraulic power for itself. The field test performed for a month shows that power output is similar or larger compared with the expected one in design stage. This paper presents the development of tidal current energy converter and real sea field test by Hyundai Heavy Industries. This project has finished successfully and provided the technical advance toward commercial services for tidal current power generation in the south-west region in Korea.

  • PDF

수평축 조류발전로터 성능실험의 수치적 재현과 연구 (Numerical Analysis of HAT Tidal Current Rotors)

  • 조철희;임진영;이강희;채광수;노유호;송승호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.620-623
    • /
    • 2009
  • 여러 해양에너지 중 유체의 빠른 흐름을 이용하는 조류발전은 서해안과 남해안에 적용하기에 적합하며 해양환경의 영향을 최소화 하면서 많은 에너지를 연속적으로 생산할 수 있는 장점이 있다. 조류발전에서 1차적으로 에너지를 변환시키는 로터는 조류발전시스템의 주요한 장치중의 하나로 여러 변수에 의해 그 성능이 결정된다. 블래이드 수, 형상, 단면적, 허브, 직경 등 여러 요소를 고려하여 로터를 설계하며, 설계정보와 실험데이터를 바탕으로 수치모델을 구현하여 실험에서 직접 계측할 수 없는 로터 주변의 유체현상 및 간섭영향 등을 예측할 수 있다. 본 논문에서는 변화하는 유속에 따른 HAT 로터의 시동속도, 회전수를 측정하여 로터 형상과 허브-직경비가 다른 로터의 성능을 고찰하고, 이를 수치모델로 구현하여 로터주변 유동변화를 연구하였다.

  • PDF