• Title/Summary/Keyword: Vertical ground reaction force

Search Result 163, Processing Time 0.024 seconds

Kinetic Analysis of Three-Point Jump Shot in Basketball (농구 3득점 점프슛 동작의 운동역학적 분석)

  • Lee, Dong-Jin;Jeong, Ik-Su
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.49-55
    • /
    • 2010
  • The purpose of the study was to analyze kinetic factors required to the three-point jump shot of the basketball games through 3-D analysis and ground reaction force(GRF) analysis. Six university male players participated in this study. The results of the study were showed that (1) resultant velocity in the center of mass(COM) was $0.84{\pm}0.27\;m/s$ since a player didn't shot a ball in the highest peak and shot ball at the moment of going up forward and vertical movement. Therefore, it is necessary to find a proper timing to shot a ball; (2) the angular velocity was largely increased in upper arm and fore arm out of the upper-limb segments and the hands had the largest angular velocity since the body is in a fixed situation and angular speed is rapidly increased by the wrist' snap with the rapid movement of upper arm and forearm at the time of release a ball; (3) it is judged that a player can shot a ball at the accurate and high release point when the player collects power vertically to the maximum by keeping GRF to the right and the rear in a proper way and by keeping the body's balance so that a large power may not be dispersed.

Changes in Balance Characteristics Affected by the Visual Information during Single Leg Stance (외발서기 시 시각정보 차단에 따른 인체 균형 특성 변화 분석)

  • Park, Jung-Hong;Kim, Gwang-Hoon;Youm, Chang-Hong;Son, Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.11
    • /
    • pp.1323-1329
    • /
    • 2011
  • The purpose of study was to analyze how the visual information affects balance control of individuals during single leg stance. A total of 27 young normal people (20 males and 7 females, age: $13.7{\pm}2.6$, height: $162.3{\pm}13.2$ cm, weight: $53.9{\pm}13.9$ kg) was voluntarily involved in the experiment. The subjects were requested to maintain balance for 20 seconds with eyes both open and closed on a force plate and then foot ground reaction data were collected for that duration. Results showed that mean velocity of COP in closed eyes condition was larger 1.84 times than that of the open-eyes condition and range of vertical angle was increased approximately one degree in the closed eyes condition. To accomplish a balance, the frequency power in mediolateral and anteroposterior components of the foot-ground reaction force was increased by 1.3~1.4 times. Consequently, visual absence during single leg stance can result in critical loss of balance and lead to instability of body control.

Accuracy and Reliability of Ground Reaction Force System and Effect of Force Platform Mounting and Environment (지면반력장비의 정밀성, 신뢰도와 장비설치.사용 환경의 영향)

  • Park, Young-Hoon;Youm, Chang-Hong;Sun, Sheng;Seo, Kook-Woong;Kim, Eui-Hwan;Kim, Tae-Whan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • Ground reaction force (GRF) measures are one of the most commonly used in biomechanical study. GRF system is very useful educational tool to explain and demonstrate the Newton's law of universal gravitation and laws of motion as well. However, accuracy, intra- and inter- force platform measures' consistency, reliability, noise, and the effect of platform mounting to GRF measures were not clearly viewed. The aim of this study was to examine the above. GRFs of a plastic dummy and two subjects' quiet upright standing were collected at four university laboratories eight force platforms. The types of platforms, analysis programs, and platform set-up were various. Three 100s-trials were conducted with sampling frequency of 100 Hz. First two trials' vertical component of GRFs, Fz, and CoP sway ranges of mid-60s-portion of 100s trials were analyzed by the paired t-tests and one-way ANOVA. Six of eight platforms' 1st and 2nd trial dummy Fz were statistically different (p<.05) and all platforms ICC were poor (<.28). Fz of the two platforms in every four laboratories were statistically different (p<.05). There were white noises and/or very distinctive noises at specific frequency ranges in all Fz measures. 5 Hz low-pass filtering made clear the Fz differences. CoP ranges of dummy were less than 0.5 cm and the best was 0.02 cm. This CoP range finding agrees with previous results suggests the importance of force platform mounting and A/D card resolution.

Effects of Contralateral and Ipsilateral Cane Use on Knee Moment (동측과 반대편의 지팡이 사용에 대한 무릎의 모멘트 분석)

  • Lee, Hyun-Ok;Yang, Kyung-Hye;Kwon, Yu-Jeong
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.117-122
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the effects of force of ipsilateral versus contralateral cane usage on knee moments in healthy young adults. Methods: A convenience sample of 10 subjects volunteered for this study. Subjects walked over a force plate under three different conditions; unaided and ipsilateral cane and contralateral cane. Analysis of data on moment of the knee joint and ground reaction force was performed using the OrthoTrak program. Results: Flexion moment of the knee was decreased with the contralateral cane, but increased with the ipsilateral cane compared with normal gait. Extension moment of the knee was decreased with the contralateral cane compared with normal gait(p<0.05) and it was showed a greater decrease with the contralateral cane than with the ipsilateral cane gait(p=0.00). Valgus moment of the knee joint was increased with the ipsilateral cane but decreased with the contralateral cane. Vertical ground peak force was decreased with the ipsilateral cane compared with normal gait (p<0.05). Conclusion: The following conclusions were drawn from our data. Contralateral cane gait is more efficacious for persons with weakness of knee extensors, however, for a patient with varus deformity, the cane should be used in the ipsilateral hand.

Kinetic characteristics of initiation of gait (보행시작의 운동역학적 특성)

  • 김봉옥;조강희
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.141-155
    • /
    • 1995
  • To understand kinetic characteristics during the process of initation of gait from standing, from the visual cue to toe off of the stance limb, vertical ground reaction forces(GRF) and center of pressure(COP) during gait initation period were evaluate with two force platforms placed side by side in thirty two adults(young 16, elderly 16, each mean age 27.79 and 51.70 years) with no history of 7 neuromusculo-skeletal abnormality. Gaint initation period of swing and stance limbs, percentage of gait initiation period and ratio of the vertical forces to body weight at each peak of the vertical forces of both limbs, and also movement of net COP were measured and described. 2 groups, one of 16 young adults and another of 16 elderly adults, were compared statistically. These data showed the increase of initiation of gait period and the decrease of movement of net COP, nd also can now be used as a part of database when initation of gait in subjects with neuromusculoskeletal abnormalities need to be evaluated.

  • PDF

Behavior of Underground Flexible Pipe According to Ground Characteristics (지반특성에 따른 지중 연성관의 거동특성)

  • Chang, Yongchai;Kim, Yonghyu;Lee, Seungeun;Park, Kichul;No, Jinsuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.41-48
    • /
    • 2009
  • A flexible pipe was buried 10cm below the ground formed with standard sand to observe changes in the shape of the pipe according to the behavior of ground at each relative density. Changes in the shape of the pipe in each ground were observed to examine the behavior of the pipe under the state of reinforced ground after installing geogrid under the pipe. Ground reinforced using geogrid formed tensile force on the reinforcement material with increase in the vertical load and showed reduction in settlement under identical vertical load with existence of reinforcement. Distributions of ground deformation of 100% relative density and 70% relative density had clear difference. Reinforced ground with 70% density converged to the ground reaction of final settlement of non-reinforced ground with 100% density at final settlement of 100 mm. Because the shape of lower part strain of the buried pipe is similar to that of un-reinforced ground with relative density of 100%, reinforcement effect by geogrid in soft ground can be anticipated.

  • PDF

Effects of Hallux Valgus Orthoses on Ground Reaction Force Using 3D Motion Analysis in Individuals With Hallux Valgus Deformity

  • Kim, Yong-wook
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.227-232
    • /
    • 2020
  • Background: Hallux valgus (HV) is a foot deformity developed by mediolateral deviation of the first metatarsophalangeal joint. Although various foot-toe orthoses were used to correct the HV angle, verification of the effects of kinetics variables such as ground reaction force (GRF) through three-dimensional (3D) gait analysis according to the various type of orthoses for HV is insufficient. Objects: This study aimed to investigate the effect of soft and hard types of foot and toe orthoses to correct HV deformity on the GRF in individuals with HV using 3D motion analysis system during walking. Methods: Twenty-six subjects participated in the experiment. Participants had HV angle of more than 15° in both feet. Two force platforms were used to obtain 3D GRF data for both feet and a 3D motion capture system with six infrared cameras was used to measure exact stance phase point such as heel strike or toe off period. Total walk trials of each participant were 8 to 10, the walkway length was 6 m. Two-way repeated measures ANOVA was used to determine the effects of each orthosis condition on the various GRF values. Results: The late anteroposterior maximal force and a first vertical peak force of the GRF showed that the hard type orthosis condition significantly increased GRF compared to the other orthosis conditions (p < 0.05). Conclusion: There were significant effects in GRF values when wearing the hard type foot orthosis. However, the hard type foot orthosis was uncomfortable to wear during walking. Therefore, it is necessary to develop a new foot-toe orthosis that can compensate for these disadvantages.

Kinetics Analysis during Stance Phase of Fore Foot Contact versus Rear Foot Contact in Running

  • Cho, Woong;Han, Jae Woong;Kim, A Young;Park, Sung Kyu;Kim, Hyung Soo
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.8 no.1
    • /
    • pp.1084-1089
    • /
    • 2017
  • The purpose of this study was to compare and analyze the difference of the ankle joint movements during landing. Seven adult males voluntarily participated in the study and the average foot size of the subjects was 269.8 mm. Image analysis equipment and the ground reaction force plate (landing type) was used to measure th kinetic variables. As a result of this study, it was confirmed that the vertical ground reaction force peak point appeared once in the barefoot with forefoot, while two peak points appeared in the barefoot and functional shoe foot with rear foot landing. About ankle angle, fore foot landing ankle angle, the average with bare foot landing was $-10.302^{\circ}$ and the average with functional shoe foot landing was $-2.919^{\circ}$. Also about rear foot landing, ankle angle was $11.648^{\circ}$ with bare foot landing and $15.994^{\circ}$ with functional shoe landing. The fore foot landing, ankle joint force analysis produced 1423.966N with barefoot and 1493.264N with functional shoes. But, the rear foot landing, ankle joint force analysis produced 1680.154N with barefoot and 1657.286N with functional shoes. This study suggest that the angle of ankle depends on the landing type and bare foot running/functionalized shod running, and ankle joint forces also depends on landing type.

Ground Reaction Force Characteristics During Forward and Backward Walking Over 20 Degree Ramp (20° 경사로 앞.뒤 보행 동작 시 지면반력의 형태 비교 분석)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.71-82
    • /
    • 2008
  • W. S. CHAE, Ground Reaction Force Charateristics During Forward and Backward Walking Over 20 Degree Ramp. Korean Journal of Sport Biomechanics, Vol. 18, No. 3, pp. 71-82, 2008. The purpose of this study was to compare GRF characteristics during forward and backward walking over 20 degree ramp. Temporal parameters, GRFs, displacement of center of pressure (DCP), and loading and decay rates were determined for each trial. The results showed that the vertical GRF in BD during RTO was significantly greater than those found in FU. This reults indicated that GRF patterns may be changed by different walking conditions and altering position of ankle, knee, and center of mass throughout the walking cycle. The DCP during $RHC_2$-LHC in antero-posterior direction for downward was smaller than the corresponding value for upward condition. It' seems that the ankle and knee joints are locked in an awkward fashion at the toe contact to compensate for imbalance. Reducing the magnitude of loading rate can be achieved by walking in the backward direction. Accordingly, the results can be a benefit if one is suffering from an impact-type injury.

An Attention-based Temporal Network for Parkinson's Disease Severity Rating using Gait Signals

  • Huimin Wu;Yongcan Liu;Haozhe Yang;Zhongxiang Xie;Xianchao Chen;Mingzhi Wen;Aite Zhao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.10
    • /
    • pp.2627-2642
    • /
    • 2023
  • Parkinson's disease (PD) is a typical, chronic neurodegenerative disease involving the concentration of dopamine, which can disrupt motor activity and cause different degrees of gait disturbance relevant to PD severity in patients. As current clinical PD diagnosis is a complex, time-consuming, and challenging task that relays on physicians' subjective evaluation of visual observations, gait disturbance has been extensively explored to make automatic detection of PD diagnosis and severity rating and provides auxiliary information for physicians' decisions using gait data from various acquisition devices. Among them, wearable sensors have the advantage of flexibility since they do not limit the wearers' activity sphere in this application scenario. In this paper, an attention-based temporal network (ATN) is designed for the time series structure of gait data (vertical ground reaction force signals) from foot sensor systems, to learn the discriminative differences related to PD severity levels hidden in sequential data. The structure of the proposed method is illuminated by Transformer Network for its success in excavating temporal information, containing three modules: a preprocessing module to map intra-moment features, a feature extractor computing complicated gait characteristic of the whole signal sequence in the temporal dimension, and a classifier for the final decision-making about PD severity assessment. The experiment is conducted on the public dataset PDgait of VGRF signals to verify the proposed model's validity and show promising classification performance compared with several existing methods.