• Title/Summary/Keyword: Vertical field

검색결과 1,679건 처리시간 0.031초

배경조건에 따른 Visual Field에서의 Stationary Field의 변화

  • 기도형;정의승;신용탁
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1994년도 춘계공동학술대회논문집; 창원대학교; 08월 09일 Apr. 1994
    • /
    • pp.375-384
    • /
    • 1994
  • Depending upon the eye and head movement, the visual field is often classified into three categories; stationary field, eye field and head field. To investigate the effect of background condition on the size of stationary field, an experiment was conducted, in which the subject was instructed to search a target with distinct orientations. In each trial, a single target was presented on the rear-view screen projected by the two-field tachistoscope, with the visual angle subtended 4.3.deg. vertically and horizontally. Density, meridian and subject showed a significant effect on stationary field at .alpha.=0.01, where density was inversely proportional to the size of stationary field. The size of the stationary field on horizontal axis was larger than that on vertical axis, and that on right and below meridian also larger than on left and lower meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. The regression equation to predict stationary field on the given background condition was suggested. These results were expected to be used as a designing guideline when arranging displays and controls on panels such as automobile display panels, cockpits, etc. In addition, it can be inferred from the results that eye field and head field are also subjected to the influence of background condition.

멀티콥터를 이용한 수직방향 DTV 신호 레벨 측정 (Measurement of Vertical-Directional DTV Signal Level Using a Multi-Copter)

  • 박형도;임솔;김대진
    • 방송공학회논문지
    • /
    • 제19권3호
    • /
    • pp.372-384
    • /
    • 2014
  • DTV 필드 테스트는 실내와 실외에서 전계강도와 수신 가능성 등을 측정하는 것으로 실외의 경우 측정 차량을 도로에서 수평적으로 이동하면서 9m 높이의 안테나를 사용 DTV 신호를 측정하였다. 현대의 고층 빌딩과 같은 수직 집단 구조의 주거 형태에서는 수직적인 DTV 신호 측정을 통하여 수직 방향 전파 환경 분석이 필요하다. 특히 전면에 장애물이 많아 다중 경로 간섭과 임펄스 잡음의 영향으로 전계강도가 수신 임계값인 $43dB{\mu}V/m$ 이상인 경우에도 수신이 불가한 경우가 있어 건물 밀집지역이나 특수한 측정 환경에 적합한 필드 측정 및 분석이 절대적으로 필요하다. 이를 위하여 자유롭게 비행하면서 DTV 수신신호 레벨을 측정할 수 있는 비행체 옥토형 멀티콥터를 개발하고 시험을 거쳐 실용성 있게 성능을 개선하였다. 휴대형 소형 DTV 수신신호 레벨 측정기와 안테나 및 데이터 전송용 M/W 송신기 또는 녹화용 장비가 탑재되어 DTV 수신신호 레벨 측정이 가능한 이 멀티콥터를 이용하여 전파환경이 다른 3지역의 측정을 통해 신뢰성 검증과 실용성을 입증하였다. 수직 방향 수신신호 레벨 측정은 수직 방향 전파 환경 변화가 큰 장소, 고층 아파트 같은 집단적 수직 주거 형태, 도보나 차량으로 접근이 불가능한 지역 등 측정점의 특수한 환경에 적합한 데이터를 얻을 수 있어 기존의 수평적 필드 테스트에서는 접근하기 어려운 장소의 전파 변화 분석에 유용하게 사용할 수 있다.

정면에 수직평판을 가진 원주의 유동장 특성실험 (Experiments on the flow field of a circular cylinder having a front vertical plate)

  • 노기덕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.198-204
    • /
    • 2016
  • 본 연구는 상류측에 작은 수직평판를 가진 원주의 유동장 특성을 양 항력측정 실험과 PIV를 이용한 가시화 실험으로 파악한 것이다. 실험 파라메터는 원주의 직경에 대한 수직평판의 폭비(H/B = 0.2~0.6) 및 원주의 앞면 중심에서부터 수직평판까지의 거리(G/B = 0~3)로 했다. 수직평판의 폭비를 고정시킨 경우 원주의 항력감소율은 간격비가 증가할수록 증가하다 감소하는 특성을 보였다. 또한 같은 간격비에서는 수직평판의 폭비가 클수록 원주의 항력감소율이 컸다. 원주의 Strouhal 수는 간격비가 증가할수록 증가하다 감소하는 특성을 보였다. 수직평판을 설치한 경우 원주 상류측과 하류측에 정체영역이 나타났으며, 그 크기는 상류측은 수직평판의 폭비가 클수록 증가하는데 비해, 하류측은 거의 일정했다.

Research on Vertical Space System of Mixed-Use Complex

  • Wang, Zhendong;Wang, Yinpu
    • 국제초고층학회논문집
    • /
    • 제4권2호
    • /
    • pp.153-160
    • /
    • 2015
  • As the predominant mode of vertical urban development in China, mixed-use complexes provide the optimal case for the research of sustainable and vertical urbanism. This paper reviews three typical mixed-use complexes with various vertical space systems in Shanghai via the combination of field observation, questionnaires and software analysis. It then proceeds to determine which vertical space system is most effective for encouraging sustainable vertical urban development from the perspective of spatial efficiency. Finally, it concludes with an evaluation of the relative capabilities of the design features of a mixed-use complex: to create external dimensional-connections, to create multiple internal connections, and to organize overall composite functions.

시각작업의 배경 조건과 8개 Meridian을 고려한 시각영역의 생성 (Generation of Visual Field Considering 8 Meridians and Background Conditions of Visual Tasks)

  • 기도형;김형수;정의승;강동석
    • 대한산업공학회지
    • /
    • 제23권3호
    • /
    • pp.533-544
    • /
    • 1997
  • Among numerous factors that have an effect on visual field, the effects of background condition on the size of the visual field were investigated to obtain more practical visual field that can be readily applicable to industrial settings. A visual experiment was conducted, in which the subject was instructed to search a target with distinct orientations. Size contrast, meridian, nontarget density, and subject's gender showed a significant effect on the size of the visual field at $\alpha=0.01$. The size of the visual field was linearly proportional to size contrast, and inversely proportional to density. Female's visual fields were found to be significantly larger than male subjects', The size of the visual field on horizontal axis was larger than that on vertical axis, and the size of the head & eye field on right meridian was also larger than that on left meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. The regression equations to predict the visual fields on the given background condition were suggested. The visual fields suggested in this study would be valuable to the design of visual displays and the panel layout of various displays and controls.

  • PDF

제품설계와 평가를 위한 시각영역의 생성 (Generation of a practical visual field for the design and evaluation)

  • 기도형
    • 대한인간공학회지
    • /
    • 제14권1호
    • /
    • pp.59-67
    • /
    • 1995
  • Depending upon the eye and head movement, the visual field is often classified into three categories ; stationary field, eye field and head and eye field. To investigate the effect of background condition on the size of the visual field, an experiment was conducted, in which the subject was instructed to search a target with distinct orientations. In each trial, a single target was presented on the perimeter modified to cover the range of 330 .deg. around the fixation point, with the visual angle subtended 1.4 .deg. vertically and horizontally. Nontarget density, meridian, size contrast and subject showed a significant effect on the visual field at .alpha. =0.01, where density was inversely proportional to the size of the visual field, and size contrast linearly proportional to the size of the visual field. The size of the visual field on horizontal axis was larger than that on vertical axis, and that on right and upper meridian was also larger than on left and lower meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. In addition, the regression equations to predict the visual field on the given background condition were suggested. These results were expected to be used as a design guideline when arranging displays and controls on panels such as automobile display panels, cockpits, etc.

  • PDF

Programming Characteristics on Three-Dimensional NAND Flash Structure Using Edge Fringing Field Effect

  • Yang, Hyung Jun;Song, Yun-Heub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.537-542
    • /
    • 2014
  • The three-dimensional (3-D) NAND flash structure with fully charge storage using edge fringing field effect is presented, and its programming characteristic is evaluated. We successfully confirmed that this structure using fringing field effect provides good program characteristics showing sufficient threshold voltage ($V_T$) margin by technology computer-aided design (TCAD) simulation. From the simulation results, we expect that program speed characteristics of proposed structure have competitive compared to other 3D NAND flash structure. Moreover, it is estimated that this structural feature using edge fringing field effect gives better design scalability compared to the conventional 3D NAND flash structures by scaling of the hole size for the vertical channel. As a result, the proposed structure is one of the candidates of Terabit 3D vertical NAND flash cell with lower bit cost and design scalability.

수직자장하에서 원관내 자성유체의 거동에 관한 연구 (A Study on the Flow Behavior of Magnetic Fluids in a Circular Pipe with a Vertical Magnetic Field)

  • 박정우;유신오;서이수
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.25-32
    • /
    • 1999
  • In the present paper, we theoretically analyze the flow of magnetic fluids in a circular pipe with a vertical magnetic field and investigate the magnetic response by the external magnetic field. Theoretical study through the governing equation derived by Siliomis is carried out with numerical analysis by the Gauss Elimination Method. Using polar and magnetic effect parameters, theoretical equations and distributions for the velocity, vorticity, internal angular momentum and induced magnetization as the magnetic response are shown. Especially, in the region of strong magnetic field the specific property is appeared by finding a critical magnetic effect parameter for a polar effect parameter.

연직드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains)

  • 이달원;강예묵
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.376-381
    • /
    • 1998
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system 1. The relation of measurement settlement( $S_{m}$) versus design settlement( $S_{t}$) and measurement consolidation ratio( $U_{m}$) versus design consolidation ratio( $U_{t}$) were shown $S_{m}$=(1.0~l.1) $S_{t}$, $U_{m}$=(1.13~l.17) $U_{t}$, at 1.0m drain spacing and $S_{m}$=(0.7~0.8) $S_{t}$, $U_{m}$=(0.92~0.99) $U_{t}$ at 1.5m drain spacing, respectively. 2. The relation of field compression index( $C_{cfield}$) and virgin compression index( $V_{cclab}$) was shown $C_{cfield}$=(1.0~1.2) $V_{cclab}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio( $C_{h}$/ $C_{v}$) were $C_{h}$=(2.4 ~ 3.0) $C_{v}$. $C_{h}$=(3.5 ~ 4.3) $C_{v}$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacingngasing of drain spacingng spacingng

  • PDF

보리새우의 전기 어법 (ELECTRICAL FISHING METHOD OF PENAEUS JAPONICUS BATE)

  • 고관서;김상한;윤갑동
    • 한국수산과학회지
    • /
    • 제5권4호
    • /
    • pp.115-120
    • /
    • 1972
  • The data Presented in this Paper, on the body and Jumping voltage of Penaeus japonicus BATE, are part of a current study on shrimp behaviour in order to improve fishing efficiency of the fishing gear. The experiments concerning electrical stimuli was mostly carried out at the Marine Laboratory of Busan Fisheries College in 1972. The following are the results obtained from the present investigations : 1. When the voltages between a pair of electrodes were fixed constant, the voltage drops between them showed almost constant electrical field. 2. Threshold voltages of the animals varied with body direction to the electrical field, i. e., 200 -500 mV for parallel, 500-1400 mV for vertical and 300-800 mV for diagonal ($45^{\circ}$) settings. 3. Jumping voltages of the animals also varied with the body direction to the electrical field; i. e., 250-1000 mV for parallel, 800-2500 mV for vertical and 400-1300 mV for diagonal settings. 4. The shrimp, in general, were more sensitive to the electrical stimuli when oriented to the cathode rather than the anode. 5. Jumping voltages decreased when the interrupted current was applied to the animals, i. e., less than 200 mV for paralled and 500mV for vertical direction of the body to the electrical field.

  • PDF