• Title/Summary/Keyword: Vertical circulation system

Search Result 97, Processing Time 0.027 seconds

A Study on Circulation System in conjunction with the multi-floored Art Museum - With reference to art museum in Europe - (미술계뮤지엄의 다층화에 따른 동선체계의 변화에 관한 연구 - 유럽 소재 뮤지엄을 중심으로 -)

  • Moon, Jung-Mook
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.107-116
    • /
    • 2010
  • In Europe, traditionally the low-rised buildings for public art museum have been constructed since the 18th century like any other buildings and these are because of the technical issue for construction difficulty. Even if the low-rised art museum buildings are still continued for it's construction, gradually the high-rised art museum buildings begin to be build due to the development of contemporary technology in high-dense modern urban space. This tendency of high-rised art museum building in recent years is expected to affect on the interior space of it and most of all the spatial change in conjunction with circulation system variation is remarkable. Because the circulation system in art museum means tourist's spatial experience and it normally controls the experience of knowledge in art museum. This study is to understand how the multi-floored art museums in Europe affect to the spatial structure and how this is related to the circulation system. And also the study raised an issue on what it's social meaning is. Through these analysis the study can provide the meaning of multi-floored art museum and basic indication in art museum planning. To understand this, the study calculated the number of stories, number of vertical circulation and number of ring-structure space. Also the study tired to use space syntax tools, which are connectivity, integration value, integration value in major space, integration value in vertical circulation and intelligibility value. those tools alculated topological transfiguration of the whole space.Throughout the study, it was concluded that the influence of high-rised art museum in Europe changed the spatial structure and circulation system. The topological center of art museum that has been the grand space since 18th century changed to the vertical circulation due to the it's roll of distributing visitors to each floor. It became a starting point of spatial deployment and experience in art museum.

A Study on the Baggage Allocation Method of Passenger-Baggage Hybrid Train (여객-화물 복합열차의 화물 배치방법에 관한 연구)

  • Choi, Yong Hoon;Shin, Sang Hoon;Han, Gee Pyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3426-3433
    • /
    • 2015
  • Three baggage allocation methods of passenger-baggage hybrid train in restricted railway transportation capacity including round conveyor system, vertical circulation system, and horizontal circulation system are presented. Loading/Unloading time is calculated based on the volume transported from Busan to Seoul via Daegu, Daejeon, and Osong with the parcel company P's logistics data. The horizontal circulation system shows less baggage volume capacity to be allocated and the maximum loading/unloading time with 434 secs. The vertical circulation system presents more loading time, but it shows best result with 408 secs. Loading/Unloading times are compared for each system and useful method is presented to improve transportation efficiency of the train.

Performance Analysis and Test of a Small-Scale Natural Circulation Vertical Evaporator (소형 자연순환 수직형 증발기 해석 및 성능실험)

  • Cha, Sang-Jin;Kim, Nae-Hyun;Ryu, Jin-Sang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.595-603
    • /
    • 2011
  • In this study, an effort has been made to analyze the subcooled boiling heat transfer in a natural circulation vertical evaporator. To verify the analysis, a small-scale model was made and tested. The friction correlation by Ueda, void fraction and quality correlation by Saha and Zuber along with the superposition heat transfer model by Rohsenow yielded a satisfactory agreement with the model test data. The analysis was extended to simulate a 1 ton/day concentration system. Comparison with the test results of 1 ton/day prototype revealed that the data were overpredicted by 13%. The capacity of the prototype was 1.2 ton/day with COP of 5.77.

A Review on the Vertical Coordinate Systems used in Oceanic and Atmospheric Circulation Numerical Model (해양 및 대기 순환 수치모델에 사용하는 연직 좌표계에 대한 고찰)

  • HyukJin Choi;Shin Taek Jeong;Hong-Yeon Cho;Dong-Hui Ko
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.36 no.4
    • /
    • pp.158-166
    • /
    • 2024
  • In a numerical method for the study of the circulation model, various vertical coordinate systems are used to simulate the physical response of the ocean and atmosphere to the increasing greenhouse gas emission. In this study, four types of vertical coordinate systems frequently used in oceanic and atmospheric circulation numerical models, i.e., height, general, pressure, and normalized vertical coordinate systems, respectively are introduced. Finally, the hydrostatic pressure equation, vertical velocity, equation of horizontal motion, and continuity equation expressed in a vertical coordinate system were introduced, and the pros and cons of the vertical coordinate system were summarized to promote the accuracy of numerical model development.

Optimizing a Low-resolution Global Ocean Circulation Model Using MOM6 (MOM6 저해상도 전지구 해양순환모델의 최적화 연구)

  • HO CHAN PARK;INSEONG CHANG;HYUNKEUN JIN;GYUNDO PAK;YOUNG-GYU PARK;YOUNG HO KIM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.29 no.3
    • /
    • pp.139-152
    • /
    • 2024
  • This study conducted various sensitivity experiments to assess and improve the performance of low-resolution global ocean circulation models. The MOM6 (Modular Ocean Model Version 6), developed by the Geophysical Fluid Dynamics Laboratory, was utilized. We focused on analyzing the effects of implementing the ePBL (energetics based planetary boundary layer) mixed layer scheme, including tidal simulation, and applying hybrid vertical coordinate system on the simulation accuracy of ocean circulation. The results revealed that the ePBL scheme effectively mitigated excessive mixed layer thickness and high temperature biases in the equatorial Pacific, while tidal simulations contributed to improving the oceanic structures in the Yellow Sea and the East Sea. Additionally, the hybrid vertical coordinate system enabled more accurate simulations of the vertical structure of temperature and salinity, enhancing model performance. This study proposes specific approaches to enhance the accuracy of ocean circulation models, contributing to global ocean and climate modeling efforts.

The Effect of Surface and Vertical Observation Data Assimilation on the Horizontal and Vertical Flow Fields Depending on the Upper Wind Conditions (종관 특성에 따른 지상 및 연직 관측자료 동화가 수평 및 연직 확산장에 미치는 영향)

  • Choi, Hyun-Jung;Lee, Hwa-Woon;Kim, Min-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.177-189
    • /
    • 2010
  • In order to incorporate correctly the large or local scale circulation in an atmospheric model, a nudging term is introduced into the equation of motion. The MM5 model was used to assess the meteorological values differences in each case, during ozone episode days in Gwangyang bay. The main objective of this study is to investigate the effect of horizontal and vertical flow fields according to the surface and vertical observation data assimilation by upper wind conditions. Therefore, we carried out several numerical experiments with various parameterization methods for nudging coefficient considering the upper wind conditions (synoptic or asynoptic condition). Nudging considering the synoptic and asynoptic nudging coefficient does have a clear advantage over dynamic initialization, therefore appropriate limitation of these nudging coefficient values on its upper wind conditions is necessary before making an assessment. Obviously, under the weak synoptic wind, there was apparent advantage associated with nudging coefficient by the regional difference. The accuracy for the prediction of the meteorological values has been improved by applying the appropriate PBL (Planetary Boundary Layer) limitation of circulation.

Studies on the Development of Three-Demensional Positioning System and Numerical Modeling of Fish Behavior I. Three-Demensional Positioning System for Investigating Fish Behavior (3차원 어군행동 계측 시스템의 개발과 어군행동의 수직 모델링에 관한 연구 1 . 3차원 어군행동 계측 시스템 -)

  • 김동수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.21-29
    • /
    • 1998
  • In order to investigate the fish behavior in the water tank, the three dimensional positioning system with two CCD cameras was designed. The positioning system was tested at the vertical circulation water channel with observational part of 1,500L$\times$1,500W$\times$500H mm and the circular water tank with 2,050ø sub(1)$\times$1,850ø sub(2)$\times$400H mm. The observational error of vertical direction was larger than that of horizontal direction, and the observational error became enlarged in all directions according to the increase of depth and distance from the visual axis. The maximum observational errors of horizontal and vertical directions at the circulation channel ranged from -1.7 cm to 1.8 cm (2.4%) and zero to 2.1 cm (4.2%), respectively. But the errors of horizontal and vertical directions at the circular tank ranged from -1.3 cm to 1.3 cm (1.3%) and zero to 1.3 cm (3.3%), respectively.

  • PDF

A Numerical Experiments on the Atmospheric Circulation over a Complex terrain around Coastal Area. Part I : A Verification of Proprietyh of Local Circulation Model Using the Linear Theory (연안부근 복잡지형의 대기유동장 수치실험 I -선형이론을 이용한 국지순환모형의 타당성 검토-)

  • 이화운;김유근;정우식
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.555-558
    • /
    • 1999
  • A sea/land breeze circulation system and a regional scale circulation system are formed at a region which has complex terrain around coastal area and affect to the dispersion and advection of air pollutants. Therefore, it is important that atmospheric circulation model should be well designed for the simulation of regional dispersion of air pollutants. For this, Local Circulation Model, LCM which has an ability of high resolution is used. To verify the propriety of a LCM, we compared the simulation result of LCM with an exact solution of a linear theory over a simple topography. Since they presented almost the same value and pattern of a vertical velocity at the level of 1 km, we had a reliance of a LCM. For the prediction of dispersion and advection of air pollutants, the wind filed should be calculated with high accuracy. A numerical simulation using LCM will provide more accurate results over a complex terrain around coastal area.

  • PDF

A Study of Vertical Circulation System in General Hospitals by Using Space Syntax (공간구문론을 이용한 종합병원 수직동선체계 연구)

  • Lee, Hyunjin;Park, Jaseung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.4
    • /
    • pp.47-60
    • /
    • 2013
  • Purpose: This study examines construction core plans for the users of vertical-typed general hospitals to effectivly use the flow line. Methods: The study sampled representative 9 hospitals, calculated the depth value through Convex Map of Space Syntax and Justified Graph according to the determination of form of construction cire, and analyzed its functional connectivity. Results: The analysis of the connectivity between operation core part and emergency part of core space with high importance in the hospitals showed that the types of hospital and hospital have the lowest depth value in the spatial phase diagram, where central treatment part and outpatient part are arranged well vertically. Elevators for patients at these hospitals are close to operation and emergency parts actually separated from the elevators for passengers. For shortening of flow line of patients and private movement environment, however, it is desirable to arrange the elevators for patients to be adjacent to the operation parts and to arrange the emergent patient entrances more effectively to separate them from the flow line of visitors and guardians. Implications: Consideration should be taken into account for the effective flow line design. This study hopefully may serve as a stepping stone for the standard design of horizontal/vertical flow line.

Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger (수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석)

  • Lee, B.C.;Kang, H.K.;Lee, M.S.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.