• Title/Summary/Keyword: Vertical Core

Search Result 365, Processing Time 0.029 seconds

Vertical Distribution of Dinoflagellate Cysts in Sediments from Gwangyang Bay, Korea (한국 남해 광양만 퇴적물에서 와편모조류 시스트의 수직적 군집 분포)

  • KIM So-Young;MOON Chang-Ho;CHO Hyun-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.3
    • /
    • pp.290-297
    • /
    • 2003
  • To describe vertical distribution of dinoflagellate cysts in bottom sediments from Gwangyang Bay, three short-core sediment samples were collected with a gravity core sampler on 24 August 2001: St. 1 core (27.5 cm) in the northeastern part of the bay, St. 14 core (30.5 cm) in the southwestern part, and St. 16 core (25.9 cm) near Yeosu Sound. Total cyst densities generally decreased from the top of the sediment samples through the bottom. The highest cyst densities were observed at 2-3 cm in St. 1 core, 4-5 cm in St. 14 core, and 0-1 cm in St. 16 core respectavely. Living cysts were observed till the bottom of the sediment samples. The increase of heterotrophic dinoflagellate cyst proportion may indicate that the eutrophication process was recently escalated in the study area.

Effect of wing width and thickness on the polarization characteristics of vertical directional couplers using the Double-Sided Deep-Ridge waveguide structure (Double-Sided Deep-Ridge 도파관 구조 수직 방향성 결합기의 날개구조부 폭과 두께가 편광 특성에 미치는 영향)

  • 정병민;윤정현;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.293-298
    • /
    • 2004
  • We investigate the effect of the wing width and thickness of a Double-Sided Deep-Ridge(DSDR) vertical directional coupler on the coupling length dependent on the polarization, We have found that the DSDR vertical directional coupler without a wing does not have polarization independent coupling lengths. The variation of the coupling length of TE and TM modes and the difference between the coupling lengths of the two modes are negligible as the wing width increases beyond the specific wing width for the same wing thickness. Thus, we can see that a DSDR vertical directional coupler has a wing width larger than the minimum wing width to obtain the polarization independent coupling length. The minimum wing width increases as the wing thickness increases for the same core thickness and as the core thickness decreases for the same wing width. Also, we have found that the minimum wing thickness is determined by the core thickness and the minimum wing thickness decreases as the core thickness increases.

A Study of Vertical Circulation System in General Hospitals by Using Space Syntax (공간구문론을 이용한 종합병원 수직동선체계 연구)

  • Lee, Hyunjin;Park, Jaseung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.4
    • /
    • pp.47-60
    • /
    • 2013
  • Purpose: This study examines construction core plans for the users of vertical-typed general hospitals to effectivly use the flow line. Methods: The study sampled representative 9 hospitals, calculated the depth value through Convex Map of Space Syntax and Justified Graph according to the determination of form of construction cire, and analyzed its functional connectivity. Results: The analysis of the connectivity between operation core part and emergency part of core space with high importance in the hospitals showed that the types of hospital and hospital have the lowest depth value in the spatial phase diagram, where central treatment part and outpatient part are arranged well vertically. Elevators for patients at these hospitals are close to operation and emergency parts actually separated from the elevators for passengers. For shortening of flow line of patients and private movement environment, however, it is desirable to arrange the elevators for patients to be adjacent to the operation parts and to arrange the emergent patient entrances more effectively to separate them from the flow line of visitors and guardians. Implications: Consideration should be taken into account for the effective flow line design. This study hopefully may serve as a stepping stone for the standard design of horizontal/vertical flow line.

Seismic fragility analysis of RC frame-core wall buildings under the combined vertical and horizontal ground motions

  • Taslimi, Arsam;Tehranizadeh, Mohsen;Shamlu, Mohammadreza
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.175-185
    • /
    • 2021
  • This study strives to highlight the importance of considering the vertical ground motions (VGM) in the seismic evaluation of RC buildings. To this aim, IDA (Incremental Dynamic Analysis) is conducted on three code-based designed high-rise RC frame-core wall buildings using a suite of earthquake records comprising of significant VGMs. To unravel the significance of the VGM inclusion on the performance of the buildings, IDAs are conducted in two states (with and without the vertical component), and subsequently based on each analysis, fragility curves are developed. Non-simulated collapse criteria are used to determine the collapse state drift ratio and the area under the velocity spectrum (SIm) is taken into account as the intensity measure. The outcome of this study delineates that the inclusion of VGM leads to the increase in the collapse vulnerability of the structures as well as to the change in the pattern of inter-story drifts and failure mode of the buildings. The results suggested that it would be more conservative if the VGM is included in the seismic assessment and the fragility analysis of RC buildings.

A novel vertical directional coupler with polarization independent very short coupling lengths (편광에 무관한 매우 짧은 결합 길이를 가지는 새로운 수직 방향성 결합기)

  • 정병민;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.359-364
    • /
    • 2003
  • We propose a novel vertical directional coupler with polarization independent very short coupling lengths using the double-sided deep-ridge waveguide structure which could be implemented using double-sided process to polarization insensitive deep-ridge waveguide structures and investigate the effect of various structure parameters on the coupling length. Variation of coupling length for the variation of the waveguide width is smaller than that for the variation of the core thickness. Coupling length decreases as the inner cladding layer thickness and the core thickness decrease. The waveguide width with the polarization independent coupling length decreases as the inner cladding layer thickness decreases for the same core thickness and the core thickness decreases for the same inner cladding layer thickness.

Open BIM-based Vertical Circulation Planning and Verifying Modules for Super-Tall Building at the Schematic Design Phase (계획설계 단계에서의 개방형 BIM 기반 초고층건축물 수직동선 계획 및 검증모듈 개발)

  • Kim, In-Han;Cho, Geun-Ha;Choi, Jung-Sik;Chun, Eui-Young
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.156-164
    • /
    • 2011
  • The automation technology is able to enhance the business process more rapidly and effective. Open BIM technology which supports automation technology of building overcomes the limitations of two dimensions drawings system. The purpose of this study is on the development of open BIM based modules for creating and verifying the core model for super-tall building in the schematic design phase. The module is expected to create cases of core models automatically and it is expected to verify the requirement of building model. This module is anticipated to utilize for creating the core model rapidly in order to create the alternative plan and to make the model accurate by its verification.

Estimation on Serrated Core Machining Load for Metal Gasket using Elasto-plastic Analysis (탄소성해석을 이용한 금속 개스킷용 톱니형 코어 가공 하중 평가)

  • Kim, Tae-Hyung;Lee, Seong-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.145-151
    • /
    • 2012
  • In this study, finite element analysis is carried out to estimate horizontal forces needed for the required power calculation and vertical forces applied on the structural analysis model for the development of automatic serrated surface at metal gasket core machining system. By considering of elasto-plastic material characteristics, nonlinear contact analysis was conducted to compute these loads according to the change of roll reduction, frictional coefficient and core thickness. As the result, horizontal and vertical reaction force variations are found according to parameters and maximum reaction force is also confirmed to be most affected by roll reduction.

Effect of refractive index difference between core and cladding on the characteristics of a vertical directional coupler using the double sided deep ridge waveguide structure (Double Sided Deep Ridge 도파관 구조를 가지는 수직 방향성 결합기의 코어와 클래딩의 굴절율 차이가 소자의 특성에 미치는 영향)

  • Yun, Jeong-Hyeon;Jeong, Byeong-Min;Kim, Bu-Gyun
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2004.02a
    • /
    • pp.300-301
    • /
    • 2004
  • Effect of refractive index difference between core and cladding on the characteristics of a vertical directional coupler using double sided deep ridge waveguide structure is investigated.

  • PDF

An experimental assessment of resistance reduction and wake modification of a KVLCC model by using outer-layer vertical blades

  • An, Nam Hyun;Ryu, Sang Hoon;Chun, Ho Hwan;Lee, Inwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.1
    • /
    • pp.151-161
    • /
    • 2014
  • In this study, an experimental investigation has been made of the applicability of outer-layer vertical blades to real ship model. After first devised by Hutchins and Choi (2003), the outer-layer vertical blades demonstrated its effectiveness in reducing total drag of flat plate (Park et al., 2011) with maximum drag reduction of 9.6%. With a view to assessing the effect in the flow around a ship, the arrays of outer-layer vertical blades have been installed onto the side bottom and flat bottom of a 300k KVLCC model. A series of towing tank test has been carried out to investigate resistance (CTM) reduction efficiency and improvement of stern wake distribution with varying geometric parameters of the blades array. The installation of vertical blades led to the CTM reduction of 2.15~2.76% near the service speed. The nominal wake fraction was affected marginally by the blades array and the axial velocity distribution tended to be more uniform by the blades array.

INFLUENCE OF VARIOUS PROPERTIES OF POST AND CORE ON THE STRESS DISTRIBUTION IN ENDODONTICALLY TREATED TOOTH (다양한 포스트와 코어의 물성이 근관치료된 치근의 응력분산에 미치는 영향)

  • Cho Jin-Hyun;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.10-19
    • /
    • 2006
  • Statement of problem : The various kinds of properties of post and core may affect the stress distribution to the root of endodontically treated teeth Purpose: To evaluate the influence of various kinds of properties of post and core to the stress distribution to the root of endodontically treated teeth. Material and methods: Mandibular first premolar, prepared by general shape of post and core with gold crown, was used to two dimensional axisymmetric modeling for finite element analysis. Then property values of 8 different kinds of post and core was substituted for each. Finally, stress distribution shown areas around the root of post and core was analysed after applying 50N of vortical and oblique load. Results: 1. Stress value of oblique load was much higher than the maximum stress value of vertical load. 2. Under oblique load, very concentrated stress was located on post periapical area and variations in stress were very severe. Contrary to this, stress distribution was relatively uniform in vertical load. 3. Post materials with higher elastic modulus showed relatively more apically focused stress, and post materials with lower elastic modulus showed stress focused on cervical area on the axial wall of post. 4. Stress change according to the properties of core was shown only in the cervical area of post and below core as the higher elastic modulus, then increased in stress. 5. Post and core with medium value of elastic modulus showed relatively uniform stress distribution. Conclusions: Post materials with higher elastic modulus showed relatively more apically focused stress, and post materials with lower elastic modulus showed stress focused on cervical area on the axial wall of post. Stress change according to the properties of core was shown only in the cervical area of post and below core.