• Title/Summary/Keyword: Vertical Axis Wind Turbine

Search Result 105, Processing Time 0.022 seconds

Power performance Testing of Small Wind Turbine Generator System (소형 풍력발전시스템의 출력성능검사)

  • Kim, Hyeon-Ki;Kim, Byeong-Min;Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.123-128
    • /
    • 2011
  • In this study, procedures, a power performance testing system of Wind Turbine System Research Center of Kangwon National University is introduced. Test prodedures and results are presented on a stand-alone vertical-axis 200W wind turbine manufactured by Geum-Poong Energy Inc.. Power performance test is performed according to IEC standard. The test results are compared with the power performance standard. Also, the effects of normalization and disturbed sectors are considered.

  • PDF

Great capacity Generator of Wind Turbine (대용량 출력 풍력발전기 설계)

  • Hur, Man-Cheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.366-368
    • /
    • 2007
  • Mr. Hur has developed the 7500KW permanent magnet synchronous generator. The 7500KW generator has dual blade system with vertical axis type generation module. The 7500KW generator will generating that it is too expensive and construction payment. The advantages of dual blade system are cheap in generation with better efficiency, and safety compact structure. But also this system has the expensive slide ring for to distribute electrical power.

  • PDF

Experimental study of the loads induced by a large-scale tornado simulation on a HAWT model

  • Lopez, Juan P.;Hangan, Horia;El Damatty, Ashraf
    • Wind and Structures
    • /
    • v.33 no.6
    • /
    • pp.437-446
    • /
    • 2021
  • As wind turbine rotors increase, the overall loads and dynamic response become an important issue. This problem is augmented by the exposure of wind turbines to severe atmospheric events with unconventional flows such as tornadoes, which need specific designs not included in standards and codes at present. An experimental study was conducted to analyze the loads induced by a tornado-like vortex (TLV) on horizontal-axis wind turbines (HAWT). A large-scale tornado simulation developed in The Wind Engineering, Energy and Environment (WindEEE) Dome at Western University in Canada, the so-called Mode B Tornado, was employed as the TLV flow acting on a rigid wind turbine model under two rotor operational conditions (idling and parked) for five radial distances. It was observed that the overall forces and moments depend on the location and orientation of the wind turbine system with respect to the tornado vortex centre, as TLV are three-dimensional flows with velocity gradients in the radial, vertical, and tangential direction. The mean bending moment at the tower base was the most important in terms of magnitude and variation in relation to the position of the HAWT with respect to the core radius of the tornado, and it was highly dependent on the rotor Tip Speed Ratio (TSR).

Experimental study of the loads induced by a large-scale tornado simulation on a HAWT model

  • Lopez, Juan P.;Hangan, Horia;El Damatty, Ashraf
    • Wind and Structures
    • /
    • v.34 no.3
    • /
    • pp.303-312
    • /
    • 2022
  • As wind turbine rotors increase, the overall loads and dynamic response become an important issue. This problem is augmented by the exposure of wind turbines to severe atmospheric events with unconventional flows such as tornadoes, which need specific designs not included in standards and codes at present. An experimental study was conducted to analyze the loads induced by a tornado-like vortex (TLV) on horizontal-axis wind turbines (HAWT). A large-scale tornado simulation developed in The Wind Engineering, Energy and Environment (WindEEE) Dome at Western University in Canada, the so-called Mode B Tornado, was employed as the TLV flow acting on a rigid wind turbine model under two rotor operational conditions (idling and parked) for five radial distances. It was observed that the overall forces and moments depend on the location and orientation of the wind turbine system with respect to the tornado vortex centre, as TLV are three-dimensional flows with velocity gradients in the radial, vertical, and tangential direction. The mean bending moment at the tower base was the most important in terms of magnitude and variation in relation to the position of the HAWT with respect to the core radius of the tornado, and it was highly dependent on the rotor Tip Speed Ratio (TSR).

Numerical Study of the blade dynamics for a cross-flow turbine

  • Sato Yuko;Kawamura Tetuya
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.230-231
    • /
    • 2003
  • Two and three-dimensional flows around a cross-flow wind turbine are investigated by the numerical simulation. The turbine studied in this paper has cylindrical shape with many small blades along its periphery. Incompressible Navier-Stokes equation is used for this simulation. A rotating coordinate system, which rotates at the same speed of the turbine, is used in order to simplify the boundary conditions on the blades of the turbine. Additionally, a boundary fitted coordinate system is employed in order to express the shape of the blades precisely. A third order upwind scheme is chosen for the approximation of the non-linear terms. When the number of blades is about 10, the highest torque is obtained.

  • PDF

Predicting Double-Blade Vertical Axis Wind Turbine Performance by a Quadruple-Multiple Streamtube Model

  • Hara, Yutaka;Kawamura, Takafumi;Akimoto, Hiromichi;Tanaka, Kenji;Nakamura, Takuju;Mizumukai, Kentaro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.1
    • /
    • pp.16-27
    • /
    • 2014
  • Double-blade vertical axis wind turbines (DB-VAWTs) can improve the self-starting performance of lift-driven VAWTs. We here propose the quadruple-multiple streamtube model (QMS), based on the blade element momentum (BEM) theory, for simulating DB-VAWT performance. Model validity is investigated by comparison to computational fluid dynamics (CFD) prediction for two kinds of two-dimensional DB-VAWT rotors for two rotor scales with three inner-outer radius ratios: 0.25, 0.5, and 0.75. The BEM-QMS model does not consider the effects of an inner rotor on the flow speed in the upwind half of the rotor, so we introduce a correction factor for this flow speed. The maximum power coefficient predicted by the modified BEM-QMS model for a DB-VAWT is thus closer to the CFD prediction.

Starting Characteristics of Darrieus Wind Turbine (다리우스 풍력터빈 발전기의 기동특성)

  • Lee, Kyu-Yong;Lee, Woo-Suk;Seo, Young-Teak;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1018-1020
    • /
    • 2003
  • Wind-powered generator system converts wind energy into utilized electric energy. Wind power generator is classified into two categories, as horizontal or vertical axis turbine. The former is equipped with yawing mechanism which is subject to set the blade-face towards the wind direction. However, the latter does not need this mechanism, but this system needs a external power for starting. This paper deals with the method how to overcome such trouble and with the analysis of the starting characteristic and a field test with a prototype of the Darrieus wind generator was performed.

  • PDF

Numerical Analysis on the Low Noise Designs of Savonius Wind Turbines by Inducing Phase Difference in Vortex Shedding (와류이탈 위상차를 이용한 사보니우스형 풍력터빈의 소음 저감 설계에 관한 수치적 연구)

  • Kim, Sanghyeon;Cheong, Cheolung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.269-274
    • /
    • 2014
  • In this study, low noise designs for a Savonius wind turbine were numerically investigated. As was reported in our previous study, the harmonic components with a fundamental frequency higher than the BPF were identified as being dominant in the noise spectrum of a Savonius wind turbine, and these components were a result of vortex shedding. On a basis of this observation, an S-shaped blade tip is proposed as a means of reducing the noise generated by small vertical(Savonius) wind turbines. This blade induces phase differences in the shedding vortices from the blades, and thus reduces the noise from the wind turbine. The aerodynamic noise characteristics of the conventional and "S-shaped" Savonius turbines were investigated by using the Hybrid CAA method where the flow field around the turbine is computed using the CFD techniques and the radiated noise are predicted by applying acoustic analogy to the computed flow field data. The degree of noise reduction resulting from the proposed design and its reduction mechanism were confirmed by comparing the predicted noise spectrum of these turbines and the flow characteristics around them.

A Fundamental Study on the Vertical-Axis Wind Turbine for Fishing Boat using Numerical Analysis (수치해석을 이용한 어선용 수직축 풍력터빈의 기초연구)

  • Jeong, Kwang-Leol;Lee, Young-Gill;Ha, Yoon-Jin;Kang, Bong Han;Kang, Dae-Sun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.6
    • /
    • pp.365-372
    • /
    • 2013
  • In this study, the flow characteristics and structural safety of a 500W class vertical-axis wind turbines(VAWT) for a fishing boat are investigated by numerical simulations. Guide vanes to increase the performance of the VAWT are investigated. And the best guide vane in the numerical simulations is applied to the VAWT. Also, modal analyses are performed to find out the natural frequencies of the VAWT, and the resonance safety of the VAWT is evaluated. The structural analysis of the VAWT is carried out by one-way FSI(Fluid Structure Interaction). And the results are used for the evaluation of structural safety according to IEC 61400-1 code. Finally, the possibility of the installation of the VAWT on the wheelhouse of a 9.77ton class fishing boat is checked. The results of the present research could be used as one of the fundamental data to design a VAWT for a fishing boat.

Improving the Self-starting Performance of a VAWT (수직축 풍차의 자기동 성능 개선)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Shon, Jae-Yul;Mag-isa, Alexander;Kim, Shin-Ho;Choi, Myoung-Su
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.13-20
    • /
    • 2006
  • The inherent problem of a Darrieus wind turbine is its inability to self-start. Usually, a motor is used to provide angular acceleration until lift forces are produced in the airfoil blades or up until the turbine can already sustain its speed on its own. This paper describes a method of improving the self-starting of an H-type Darrieus vertical axis wind turbine (VAWT) by incorporating a helical Savonius turbine thus utilizing a drag-lift combination. The effect of each turbine in the combination relative to each other is investigated by testing a prototype windmill consisting of three NACA 0015 airfoil blades combined with a Savonius rotor with a helix angle of 180 degrees and whose swept area equals 30% of the entire turbine.

  • PDF