• Title/Summary/Keyword: Vertebral body

Search Result 342, Processing Time 0.025 seconds

Development of a Semi-Automated Detection Method and a Classification System for Bone Metastatic Lesions in Vertebral Body on 3D Chest CT (3차원 흉부 CT에서 추체 골 전이 병변에 대한 반자동 검출 기법 및 분류 시스템 개발)

  • Kim, Young Jae;Lee, Seung Hyun;Choi, Ja Young;Sun, Hye Young;Kim, Kwang Gi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.10
    • /
    • pp.887-895
    • /
    • 2013
  • Metastatic bone cancer, the cancer which occurred in the various organs and progressively spread to bone, is one of the complications in cancer patients. This cancer is divided into the osteoblast and osteolytic metastasis. Although Computer Tomography(CT) could be an useful tool in diagnosis of bone metastasis, lesions are often missed by the visual inspection and it makes clinicians difficult to detect metastasis earlier. Therefore, in this study, we construct a three-dimensional(3D) volume rendering data from tomography images of the chest CT, and apply a 3D based image processing algorithm to them for detection bone metastasis lesions. Then we perform a three-dimensional visualization of the detected lesions.From our test using 10 clinical cases, we confirmed 94.1% of average sensitivity for osteoblast, and 90.0% of average sensitivity, respectively. Consequently, our findings showed a promising possibility and potential usefulness in diagnosis of metastastic bone cancer.

Giant Cell Tumor of the Cervical Spine - Case Report - (경추에 발생한 거대 세포종 - 증례 보고 -)

  • An, Ki-Chan;Chung, Kyung-Chil;Kim, Yoon-Jun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Giant cell tumors are potentially malignant tumors in vertebrae, affecting frequently difficult to diagnose and are often inoperable. So it will be treated using radiation because of their high recurrence rate and the mechanical compression of spinal cord, but many surgeons described tumors of the vertebra, and the affected vertebral body can be treated using radical or near to total excision, with anteroposterior vertebral fusion or instrumentation of the spine. we report a case of giant cell tumor affecting the third cervical vertebra which caused neck pain and destroyed the vertebra body had treated using radical excison with fusion of posterior arch using instrumentation of the spine together with a literature review.

  • PDF

Determination of Adequate Entry Angle of Lumbar Sympathetic Ganglion Block in Korean

  • Kim, Won-Ho;Kim, Sang-Kwon;Lee, Chul-Joong;Kim, Tae-Hyeong;Sim, Woo-Seok
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • Background: The target of lumbar sympathetic ganglion block is the anterolateral surface of the L2, 3 and 4 vertebral bodies, where the lumbar sympathetic ganglion usually lies. In most cases, a block-needle is inserted approximately 5-8 cm lateral to spinous process on the skin and directed to the anterolateral surface of vertebral body obliquely. The purpose of this study is to determine the safe entry angle and entry point in Korean by using the abdominal CT scan images. Methods: The abdominal CT images of eighty five patients were recruited to this study. The minimal angle aimed at the lumbar sympathetic ganglion that can pass through the lateral aspect of body and maximal angle that avoids puncturing the kidney, ureter or retroperitoneal space were measured. The distance from midline to skin entry point was also measured. Results: There was no significant difference in entry angle among L2, 3, and 4 level. The entry angle was similar in the right and left side, and in males and females. The entry angle of old age group was significantly smaller than that of young age group. The calculated safe entry angle was $30.5{\pm}0.4^{\circ}$ and entry point was $7.7{\pm}0.2\;cm$ and $6.7{\pm}0.1\;cm$ lateral from midline in males and females respectively. Conclusions: These measurements can be used as a reference for lumbar sympathetic ganglion block and radiofrequency lesioning. Prior to performing the lumbar sympathetic ganglion block for cancer patients, the abdominal CT scan should be reviewed to prevent complications.

Short-segment Pedicle Instrumentation of Thoracolumbar Burst-compression Fractures; Short Term Follow-up Results

  • Shin, Tae-Sob;Kim, Hyun-Woo;Park, Keung-Suk;Kim, Jae-Myung;Jung, Chul-Ku
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2007
  • Objective : The current literature implies that the use of short-segment pedicle screw fixation for spinal fractures is dangerous and inappropriate because of its high failure rate, but favorable results have been reported. The purpose of this study is to report the short term results of thoracolumbar burst and compression fractures treated with short-segment pedicle instrumentation. Methods : A retrospective review of all surgically managed thoracolumbar fractures during six years were performed. The 19 surgically managed patients were instrumented by the short-segment technique. Patients' charts, operation notes, preoperative and postoperative radiographs (sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis, regional kyphosis), computed tomography scans, neurological findings (Frankel functional classification), and follow-up records up to 12-month follow-up were reviewed. Results : No patients showed an increase in neurological deficit. A statistically significant difference existed between the patients preoperative, postoperative and follow-up sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis and regional kyphosis. One screw pullout resulted in kyphotic angulation, one screw was misplaced and one patient suffered angulation of the proximal segment on follow-up, but these findings were not related to the radiographic findings. Significant bending of screws or hardware breakage were not encountered. Conclusion : Although long term follow-up evaluation needs to verified, the short term follow-up results suggest a favorable outcome for short-segment instrumentation. When applied to patients with isolated spinal fractures who were cooperative with 3-4 months of spinal bracing, short-segment pedicle screw fixation using the posterior approach seems to provide satisfactory result.

Huge pheochromocytoma presented with paraaortic lymph node and spine metastases (척추와 대동맥주위 림프절로 전이한 거대 갈색세포종)

  • Park, Yeon Won;Moon, Han Ju;Han, Jung Suk;Han, Ji Min;Park, Jong Wook;Ku, Yun Hyi
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.247-253
    • /
    • 2017
  • Approximately 10-15% of pheochromocytomas are malignant. There are insufficient histologic criteria for the diagnosis of malignant pheochromocytoma. Thus, the term malignant pheochromocytoma is restricted to tumors with local invasion or distant metastases. We experienced a case of malignant pheochromocytoma recurred with spinal metastasis 4 years after the surgery for huge benign pheochromocytoma. A 68-year-old female was admitted for trunk and back pain. The patient had a history of surgery 4 years ago for a $10.0{\times}9.5{\times}7.5cm$ sized benign pheochromocytoma at the left adrenal gland. A thoracolumbar magnetic resonance imaging showed a tumor in the 7th thoracic vertebral body and a 24-hour urinary norepinephrine increased, suggesting metastatic recurrence of malignant pheochromocytoma. After metastasectomy in the 7th thoracic vertebral body, urine catecholamine was normalized and pain also disappeared. However, a metastatic lesion was found in the paraaortic area on a follow-up abdominal computed tomography scan and an additional metastasectomy was performed. The pathology confirmed the diagnosis of metastatic pheochromocytoma in the paraaortic lymph nodes. She is supposed to be treated with adjuvant iodine 131-meta-iodobenzylguanidine therapy. In our experience, a close follow-up should be considered in patients who had a huge benign pheochromocytoma due to the possibility of malignant metastases.

Clinical Significance of Radiological Stability in Reconstructed Thoracic and Lumbar Spine Following Vertebral Body Resection

  • Sung, Sang-Hyun;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2014
  • Objective : Vertebral body replacement following corpectomy in thoracic or lumbar spine is performed with titanium mesh cage (TMC) containing any grafts. Radiological changes often occur on follow-up. This study investigated the relationship between the radiological stability and clinical symptoms. Methods : The subjects of this study were 28 patients who underwent corpectomy on the thoracic or lumbar spine. Their medical records and radiological data were retrospectively analyzed. There were 23 cases of tumor, 2 cases of trauma, and 3 cases of infection. During operation, spinal reconstruction was done with TMC and additional screw fixation. We measured TMC settlement in sagittal plane and spinal angular change in coronal and sagittal plane at postoperative one month and last follow-up. Pain score was also checked. We investigated the correlation between radiologic change and pain status. Whether factors, such as the kind of graft material, surgical approach, and fusion can affect the radiological stability or not was analyzed as well. Results : Mean follow-up was 23.6 months. During follow-up, $2.08{\pm}1.65^{\circ}$ and $6.96{\pm}2.08^{\circ}$ of angular change was observed in coronal and sagittal plane, respectively. A mean of cage settlement was $4.02{\pm}2.83mm$. Pain aggravation was observed in 4 cases. However, no significant relationship was found between spinal angular change and pain status (p=0.518, 0.458). Cage settlement was seen not to be related with pain status, either (p=0.644). No factors were found to affect the radiological stability. Conclusion : TMC settlement and spinal angular change were often observed in reconstructed spine. However, these changes did not always cause postoperative axial pain.

Diagnostic Radiology and Conservative Management of L1 Lumbar Spine with Compression Fracture (L1 요추 압박골절에 대한 진단방사선학 및 보존적 치료)

  • 김재웅
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.165-170
    • /
    • 1998
  • Diagnostic radiology and conservative management for S75 patient with L1 lumbar fracture by traffic accidents were discussed with references, and then the obtained results were as follows ; 1. Wedging compression fractures with 10% deformity was confirmed at anterior vertebral body of L1 lumbar spine through lateral plain X-ray film. 2. Irregular bony fractures were observed at anterior vertebral body of L1 lumbar spine by CT scans, anatomically T12-L1 sites showed highly frequency of injuries, Denis's fracture type was classified as multiple compression fracture at anterior column without abnormal middle and posterior column, also no Cobb's angle, and then Frankel's neurological classification was E grade. 3. Orthopaedic treatments were performed with conservative methods. With rest on the bed, anti-in-flammatory medication, electrolyte and nutritional solution, the pain diminished. 4. After 3 weeks, rehabilitation was worked with putting on polyethylene back corset, although pains remained slightly until after 8 weeks, thereafter the spine showed gradually stability.

  • PDF

Effects of Laennec.N.HO (Hominis placenta.Cervi pontotrionum cornu.Carthami semen) aqua-acupuncture on the ovariectomized osteoporotic Rats (자하거(紫河車).녹용(鹿茸).홍화자(紅花子) 약침액(藥鍼液)이 난소적출(卵巢摘出)로 골다공증(骨多孔症)을 유도(誘導)한 흰쥐에 미치는 영향(影響))

  • Jang, Su-Jin;Lee, Chang-Hyun;Yook, Tae-Han
    • The Journal of Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.5-18
    • /
    • 1998
  • The purpose of this study was to determine the effects of aqua-acupuncture of Laennec N HO (Hominis placenta Cervi pontotrichum cornu Carthami semen). on trabecular area and physiological change in ovariectomized osteoporotic rats. This experiment was performed to .investigate an antiosteoporosis. effects of Laennec N HO(Hominis placenta Cervi pontotrichum cornu Carthmi semen) aqua-acupuncture on the osteoporosis induced by both ovariectomy in Rats. So rats were divided into Sham group and OVX group. OVX groups were divided into control group, Exp. I group, Exp II group and Exp III group). The Ratios of trabecular area seen in ephiphysis and diaphysis of tibia and lumbar vertebral body and physiological change were as follows. 1. In the proximal ephiphysis of tibia, Exp I II III groups were significantly increased compared to that in control group (p<0.05). 2. In the diaphysis of tibia, Exp III group were significantly increased compared to that in control group (p<0.05). 3. In the first lumbar vertebral body, Exp II group were significantly increased compared to that in control group. 4. In the cortical thickness index of tibia, Exp III III groups were significantly increased compared to that in control group. 5. Osteoca1cin was increased in the Exp II group than those of other Experiment groups and control group, and Phosphorus was decreased in the Exp I II group than that in control group, But a significant difference was not seen. GOT, GPT and Alkaline phosphatase were decreased in all Experiment groups than that in control group. But a significant difference was not seen. From the above results, it might be suggested that aqua-acupuncture Laennec N HO(Hominis placenta Cervi pontotrichum cornu Carthami semen) prevented the increase in bone turnover and the decrese in bone mass induced by OVX in rats.

  • PDF

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

The Effect of Repetitive Insertion and Pullout of Spinal Screws on Pullout Resistance : A Biomechanical Study (척추 수술에 사용되는 나사못의 반복 삽입과 인출이 인장항력에 미치는 영향 : 생체 역학적 연구)

  • Bak, Koang Hum;Ferrara, Lisa;Kim, Kwang Jin;Kim, Jae Min;Kim, Choong Hyun;Benzel, Edward C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Object : The clinical uses of screws are increasing with broader applications in spinal disorders. When screws are inserted repeatedly to achieve optimal position, tips of screw pitch may become damaged during insertion even though there are significant differences in the moduli of elasticity between bone and titanium. The effect of repeated screw insertion on pullout resistance was investigated. Methods : Three different titanium screws(cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw) were inserted into the synthetic cancellous material and then extracted axially at a rate of 2.4mm/min using Instron(Model TT-D, Canton, MA). Each set of screws was inserted and pulled out three times. There were six screws in each group. The insertional torque was measured with a torque wrench during insertion. Pullout strength was recorded with a digital oscilloscope. Results : The mean pullout force measurements for the cortical lateral mass screws($185.66N{\pm}42.60$, $167.10N{\pm}27.01$ and $162.52 N{\pm}23.83$ for first, second and third pullout respectively : p=0.03) and the cervical vertebral body screws($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024) showed consecutive decrease in pullout resistance after each pullout, whereas the cancellous lateral mass screws did not($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and 199.49N(36.63 : p=0.24). The SEM after insertion and pullout three times showed a blunting in the tip of the screw pitch and a smearing of the screw surface. Conclusions : Repetitive screw insertion and pullout resulted in the decrease of pullout resistance in certain screws possibly caused by blunting the screw tip. This means screw tips suffer deformations during either repeated insertion or pullout. Thus, the screws that have been inserted should not be used for the final construct.

  • PDF