• Title/Summary/Keyword: Vertebral artery dissection

Search Result 14, Processing Time 0.023 seconds

Long-Term Outcomes of Stenting on Non-Acute Phase Extracranial Supra-Aortic Dissections

  • Jiang, Yeqing;Di, Ruoyu;Lu, Gang;Huang, Lei;Wan, Hailin;Ge, Liang;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.422-429
    • /
    • 2022
  • Objective : Extracranial supra-aortic dissections (ESADs) with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke. Endovascular stenting to reconstruct non acute phase ESADs (NAP-ESADs) is an alternative to anticoagulant or antiplatelet therapy. However, its feasibility, safety and efficacy of stenting in NAP-ESADs is unclear. This study aims to investigate the long-term outcomes of the feasibility, safety and efficacy of stenting in NAP-ESADs. Methods : Seventy-four patients with 91 NAP-ESAD vessels with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke who underwent stent remodeling were enrolled into this respective study from December 2008 to March 2020. Technical success rate, complications, clinical and angiographic results were harvested and analyzed. Results : Success rate of stent deployment was 99% (90/91) with no procedural mortality or morbidity. Transient ischemic attack occurred in three patients during operation (4.1%, 3/74). Asymptomatic embolisms of distal intracranial vessels were found in two patients (2.7%, 2/74). One hundred and forty-two stents deployed at 85 carotid (135 stents) and six vertebral (seven stents) vessels. Six stent types (Wingspan, 28/135, 20.7%; Solitaire, 10/135, 7.4%; Neuroform, 8/135, 5.9%; LVIS, 2/135, 1.5%; Precise, 75/135, 55.6%; Acculink, 12/135, 8.9%) were deployed at carotid arterial dissection while two types (Wingspan, 5/7, 71.4%; Solitaire 2/7, 28.6%) at vertebral arterial dissection. Digital subtracted angiography (56%, 51/91), computational tomography angiography (41.8%, 38/91) and high resolution magnetic resonance imaging (2.2%, 2/91) were adopted for follow up, with a mean time of 17.2±15.4 months (5-77). All patient modified Rankin Scale scores showed no increase at discharge or follow-up. Angiographically, dissections in 86 vessels in 69 patients (94.5%, 86/91) were completely reconstructed with only minor remnant dissections in four vessels in four patients (4.4%, 4/91). Severe re-stenosis in the stented segment required re-stenting in one patient (1.1%, 1/91). Conclusion : Stent remodeling technique provides feasible, safe and efficacious treatment of ESADs patients with severe stenosis, occlusion and/or pseudoaneurysm.

A Case Report of Pontine Infarction as an Initial Manifestation of Systemic Lupus Erythematosus: Diagnostic Clues from MRI and Digital Subtraction Angiography (전신성 홍반성 루푸스의 초기 증상으로 나타난 교뇌경색의 증례 보고: 자기공명영상 및 디지털감산 혈관조영술에서의 진단 단서)

  • Mi Sun Chung;Jun Soo Byun;Younghee Yim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1281-1286
    • /
    • 2021
  • Brainstem infarction due to vertebrobasilar insufficiency is a rare initial presentation of systemic lupus erythematosus (SLE) patients and small-vessel dissection as the direct cause of infarction has not been reported. We report the case of a 20-year-old female with acute infarction on the right side of the pons due to a small artery (pontine perforator) dissection, identified on digital subtraction angiography and high-resolution vessel wall MRI (vwMRI). She was diagnosed with SLE based on the presence of neurologic disorders and relevant laboratory findings. The pontine perforator-dissecting aneurysm had occluded and the right distal vertebral artery had resolved on subsequent vwMRI. She had a modified Rankin Scale (mRS) score of 1 at discharge with mild symptom improvement, and exhibited no further aggravation of symptoms at 3 or 12 months, maintaining an mRS score of 1.

Review on Efficacy and Safety of Manipulation Therapy including Chuna Manipulation (추나요법을 포함한 수기치료의 효과 및 안전성에 관한 문헌고찰)

  • Kim, Ki-Byoung;Park, Tae-Yong;Lee, Jeong-Han;Kong, Jae-Cheol;Lee, Su-Kyung;Shin, Byung-Cheul;Kwon, Young-Dal;Song, Yung-Sun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.4
    • /
    • pp.103-120
    • /
    • 2008
  • Objectives : This study aims to educate clinical doctors of the valuable practice of Manipulative Therapy(MT) as an opportunity for evidence-based medicine. Consequently it also serves to review the effectiveness and safety of MT. Methods : The literature studies of overseas were done by Cochrane Library and Medline website; those of domestic researches were completed by utilizing the sources which are gained from KERIS, KISS, DBpia, Kisti, and domestic institutes related with MT. Results : Eight papers related to the effectiveness of MT were published in South Korea, which concluded with the positive effects of MT. None of them are, however, well-designed randomized controlled trials(RCT). On the other hand, fifteen cases of nine articles indicate the adverse reaction of MT, and numbers of the researches in overseas revealed the side effects of MT in order of cervical, lumbar, and thoracic vertebrae. A vascular adverse reaction such as vertebral and carotid artery dissection was a highly reported cervical adverse reaction; in the thoracic and lumbar regions, neurological adverse reaction in terms of disc hemiation was frequently discovered. Conclusions : Henceforth, highly qualitative studies are required developing the effective outcomes and preventing any possible complications of MT. Therefore, systemic curriculums in institutions and sufficient clinical training in the filed are strongly recommended.

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF