• 제목/요약/키워드: Vertebral artery dissection

검색결과 14건 처리시간 0.019초

Long-Term Outcomes of Stenting on Non-Acute Phase Extracranial Supra-Aortic Dissections

  • Jiang, Yeqing;Di, Ruoyu;Lu, Gang;Huang, Lei;Wan, Hailin;Ge, Liang;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권3호
    • /
    • pp.422-429
    • /
    • 2022
  • Objective : Extracranial supra-aortic dissections (ESADs) with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke. Endovascular stenting to reconstruct non acute phase ESADs (NAP-ESADs) is an alternative to anticoagulant or antiplatelet therapy. However, its feasibility, safety and efficacy of stenting in NAP-ESADs is unclear. This study aims to investigate the long-term outcomes of the feasibility, safety and efficacy of stenting in NAP-ESADs. Methods : Seventy-four patients with 91 NAP-ESAD vessels with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke who underwent stent remodeling were enrolled into this respective study from December 2008 to March 2020. Technical success rate, complications, clinical and angiographic results were harvested and analyzed. Results : Success rate of stent deployment was 99% (90/91) with no procedural mortality or morbidity. Transient ischemic attack occurred in three patients during operation (4.1%, 3/74). Asymptomatic embolisms of distal intracranial vessels were found in two patients (2.7%, 2/74). One hundred and forty-two stents deployed at 85 carotid (135 stents) and six vertebral (seven stents) vessels. Six stent types (Wingspan, 28/135, 20.7%; Solitaire, 10/135, 7.4%; Neuroform, 8/135, 5.9%; LVIS, 2/135, 1.5%; Precise, 75/135, 55.6%; Acculink, 12/135, 8.9%) were deployed at carotid arterial dissection while two types (Wingspan, 5/7, 71.4%; Solitaire 2/7, 28.6%) at vertebral arterial dissection. Digital subtracted angiography (56%, 51/91), computational tomography angiography (41.8%, 38/91) and high resolution magnetic resonance imaging (2.2%, 2/91) were adopted for follow up, with a mean time of 17.2±15.4 months (5-77). All patient modified Rankin Scale scores showed no increase at discharge or follow-up. Angiographically, dissections in 86 vessels in 69 patients (94.5%, 86/91) were completely reconstructed with only minor remnant dissections in four vessels in four patients (4.4%, 4/91). Severe re-stenosis in the stented segment required re-stenting in one patient (1.1%, 1/91). Conclusion : Stent remodeling technique provides feasible, safe and efficacious treatment of ESADs patients with severe stenosis, occlusion and/or pseudoaneurysm.

전신성 홍반성 루푸스의 초기 증상으로 나타난 교뇌경색의 증례 보고: 자기공명영상 및 디지털감산 혈관조영술에서의 진단 단서 (A Case Report of Pontine Infarction as an Initial Manifestation of Systemic Lupus Erythematosus: Diagnostic Clues from MRI and Digital Subtraction Angiography)

  • 정미선;변준수;임영희
    • 대한영상의학회지
    • /
    • 제82권5호
    • /
    • pp.1281-1286
    • /
    • 2021
  • 척추기저동맥의 혈류공급감소로 인한 뇌간 경색은 매우 드문 전신성 루푸스 환자의 초기 증상으로, 경색의 직접적인 원인으로 매우 작은 기저동맥 분지인 교뇌공급혈관의 박리성 동맥류는 보고된 사례가 없다. 이에 저자들은 디지털감산 혈관조영술과 고해상도 혈관벽 자기공명영상를 이용하여 작은 교뇌공급혈관의 박리성 동맥류의 진단과 추적관찰 중 치유된 20세 여성의 사례를 보고하고자 한다. 전신성 루푸스의 진단은 신경학적장애의 유무와 혈액화학검사 결과를 바탕으로 하였다. 추적 고해상도 혈관벽 자기공명영상에서 환자의 교뇌천공지의 박리성동맥류는 폐색되어 있었고 우측 척추동맥의 박리성동맥류는 치유되어 보이지 않았다. 환자는 퇴원 시 수정랭킨척도 점수가 1점으로 증상 개선을 보였으며 3개월과 12개월 추적관찰에서도 증상이 악화되지 않고 1점을 유지하였다.

추나요법을 포함한 수기치료의 효과 및 안전성에 관한 문헌고찰 (Review on Efficacy and Safety of Manipulation Therapy including Chuna Manipulation)

  • 김기병;박태용;이정한;공재철;이수경;신병철;권영달;송용선
    • 한방재활의학과학회지
    • /
    • 제18권4호
    • /
    • pp.103-120
    • /
    • 2008
  • Objectives : This study aims to educate clinical doctors of the valuable practice of Manipulative Therapy(MT) as an opportunity for evidence-based medicine. Consequently it also serves to review the effectiveness and safety of MT. Methods : The literature studies of overseas were done by Cochrane Library and Medline website; those of domestic researches were completed by utilizing the sources which are gained from KERIS, KISS, DBpia, Kisti, and domestic institutes related with MT. Results : Eight papers related to the effectiveness of MT were published in South Korea, which concluded with the positive effects of MT. None of them are, however, well-designed randomized controlled trials(RCT). On the other hand, fifteen cases of nine articles indicate the adverse reaction of MT, and numbers of the researches in overseas revealed the side effects of MT in order of cervical, lumbar, and thoracic vertebrae. A vascular adverse reaction such as vertebral and carotid artery dissection was a highly reported cervical adverse reaction; in the thoracic and lumbar regions, neurological adverse reaction in terms of disc hemiation was frequently discovered. Conclusions : Henceforth, highly qualitative studies are required developing the effective outcomes and preventing any possible complications of MT. Therefore, systemic curriculums in institutions and sufficient clinical training in the filed are strongly recommended.

경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교 (Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength)

  • 박춘근;황장회;지철;이재언;성재훈;최승진;이상원;;박성찬;조경석;박춘근;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1210-1219
    • /
    • 2001
  • 서 론 : 후방 경유 경추 융합을 위한 후관절 금속판 고정술은 외상성 및 퇴행성 불안정성의 치료에 효과적인 방법이다. 후관절 금속판 고정의 안정성은 여러 가지 인자에 의해 결정된다. 이중 하나가 나사못의 삽입깊이이다. 이 방법이 처음 소개될 때에는 양피질골성 삽입이 이용되었다. 외과의사의 관심은 어떻게 안전하면서 생역학적으로 강력한 고정을 얻느냐에 있다. 목 적 : 이 연구의 목적은 사체에서 단피질성과 양피질성 나사못 삽입술을 시행한 후 안전성, pull-out 강도, 방사선학적 특성을 분석하고 나사못의 삽입에 대한 교육 훈련의 수준에 따른 영향을 평가하는데 있다. 방 법 : 평균 나이 78.9세인 21구의 사체에 대하여, Magerl의 기술을 변형하여 C3-C6(n=168)까지 3.5mm AO 나사못을 양쪽 후관절에 삽입하였다. 수술중 방사선 사진영상은 사용되지 않았다. 오른 쪽(단피질성 삽입)은 14mm 나사못(11mm의 유효 길이)을 이용하고, 왼쪽은 양피질성 삽입을 시도하였다. 각 사체는 3개의 군으로 나누어 척추 수술 수련의 수준이 다른 받은 3명의 척추 외과 의사들(전임 강사, 임상 강사, 수석 레지던트)이 수술을 시행했다. 수술 후 경추를 떼어내어 나사못의 위치를 육안적으로 확인하고 방사선학적으로 안정성과 삽입 위치 (1,2,3)를 평가하였다. 척수, 후관절, 신경근과 척추 동맥에 대한 나사못의 위치를"만족할 만한","위험한", 그리고"직접적인 손상"으로 구분하였다. material testing machine을 이용하여 모든 나사못에 대해서 Pull-out 강도를 측정하였다. 결 과 : 대다수의 나사못(92.9%)은 만족할 만한 상태였다. 전예에서 척수에 대한 위험성은 없다. 오른 편(단피질성 : 14mm) 나사못의 98.9%는"만족할 만한"에 속했다. 그리고 왼쪽 편(양피질성)의 68.1%는"만족할 만한"에 속했다. 양피질성 나사못 군에서 5.8%의 척추 동맥에 대한 직접적인 손상이 있었고 신경근의 직접적인 손상 발생율은 17.4%였다. 반면에 단피질성 나사못 군에서는 이들에 대한 직접적인 손상은 없었다. 양피질성 나사못에서 보인"직접 손상"의 거의 대부분은 외과 의사의 경험 부족으로 발생하였다. 나사못의 안정성과 삽입 위치 사이에는 특별한 관련이 없었다. 모든 나사못의 pull-out 강도는 $542.0{\pm}296.6N$였다. 단피질성에 있어서의 pull-out 강도($519.0{\pm}289.9N$)와 양피질성($565.2{\pm}306N$) 나사못에는 아무런 통계학적으로 의미있는 차이점을 발견할 수 없었다(p>0.05). 나사못 삽입위치와 pull-out 강도 사이에는 의미있는 차이가 없었다. 결 론 : 이번 연구는 경추 후관절 나사못 고정술시 단피질성과 양피질성 나사못의 안정성과 효능을 집중적으로 알아보았다. 명백한 것은 14mm의 나사못(효과적인 길이는 11mm)이 보다 긴 양피질성 나사못 보다 손상의 위험이 훨씬 낮고 거의 동등한 pull-out강도를 갖는다는 것이다. 또한, 수술시 방사선 영상을 사용할 수 없을 때, 훈련과 축적된 경험에 의해 나사못 삽입의 정확성과 안전성이 향상될 수 있다.

  • PDF