• Title/Summary/Keyword: Vertebral Alignment

Search Result 23, Processing Time 0.02 seconds

The Safety and Efficacy of Cadaveric Allografts and Titanium Cage as a Fusion Substitutes in Pyogenic Osteomyelitis

  • Kim, Hyun-Woo;Ryu, Je-Il;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.348-356
    • /
    • 2011
  • Objective : The safety and efficacy of various fusion substitutes in pyogenic osteomyelitis has not been investigated. We evaluated and compared the cadaveric allograft and titanium cages used to reconstruct, maintain alignment and achieve fusion in the management of pyogenic spinal infection. Methods : There were 33 patients with pyogenic osteomyelitis underwent fusion in this study. Fifteen of the 33 patients were operated on by fusion with allografts (cadaveric patella bones) and 18 of those were operated with titanium mesh cages filled with autologous cancellous iliac bone. After the affected disc and vertebral body resection with pus drainage, cadaveric allograft or titanium cages were inserted into the resected space. Posterior transpedicular screw fixation and rod compression in resected space, where cadaveric allograft or titanium cages were inserted, was performed to prevent the malposition in all patients except in 1 case. Recurrent infection was identified by serial erythrocyte sedimentation rate and cross reactive protein follow-up. Osseous union and recurred infection available at a minimum of 2 years following operation was identified. The amount of kyphosis correction and the subsidence were measured radiographically. Results : Spinal fusion was achieved in 29 of 33 patients. In the cadaveric allograft group, 93.3% of patient (14 of 15) showed the osseous union while 83.3% of patient (15 of 18) in the titanium cage group showed union. Subsidence was noted in 12 of the patients. Twelve patients (36.3%) showed unsettling amounts of subsidence postoperatively whereas 46.6% of patients in the cadaveric allograft group and 37.7% of patients in the titanium cage group showed similar subsidence, respectively. There were statistical difference in the fusion rate (p=0.397) and subsidence rate (p=0.276) between the two groups. There was significant statistical difference in the postoperative improvement of segmental kyphosis between the two groups (p=0.022), that is the improvement in sagittal alignment was greater in the titanium cage group than in the cadaveric allograft group. There was no case of recurred infection. Conclusion : The cadaveric allograft and titanium cages are effective and safe in restoring and maintaining sagittal plane alignment without increased incidence in infection recurrence in pyogenic osteomyelitis. The postoperative improvement of segmental kyphosis was better in the cage group.

Titanium Mesh Cage for Anterior Stabilization in Tuberculous Spondylitis : Is It Safe?

  • Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Kim, Seung-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.412-418
    • /
    • 2006
  • Objective : The safety of titanium metal cages in tuberculous spondylitis has not been investigated. We evaluated the outcome and complications of titanium mesh cages for reconstruction after thoracolumbar vertebrectomy in the tuberculous spondylitis. Methods : There were 17 patients with 18 operations on the tuberculous spondylitis in this study. Sixteen patients were operated with anterior corpectomy and reconstruction with titanium mesh cage followed by posterior transpedicular screw fixations on same day, two pateints were operated by either anterior or posterior approach only. After the affected vertebral body resection and pus drainage from the psoas muscle, titanium mesh cage, filled with morselized autogenous bone, was inserted. All the patients had antituberculosis medication for 18 months. The degree of kyphosis correction and the subsidence of cage were measured in the 15 patients available at a minimum of 2 years. Outcome was assessed with various cross-sectional outcome measures. Recurrent infection was identified by serial ESR[Erythrocyte Sedimentation Rate] and CRP[Cross Reactive Protein]. Results : There was no complication from the use of a titanium mesh cage. Recurrent infection was not detected in any case. Average preoperative of $9.2^{\circ}$ was reduced to $-2^{\circ}$ at immediate postoperative period, and on final follow up period kyphotic angle was measured to be $4.5^{\circ}$. Postoperatively, subsidence was detected in most patients especially at ambulation period, however further subsidence was prevented by the titanium mesh cage. Osseous union was identified in all cases at the final follow-up. Conclusion : The cylindrical mesh cage is a successful instrument in restoring and maintaining sagittal plane alignment without infection recurrence after vertebrectomy for tuberculous spondylitis.

Analysis of the Risk Factors for Unfavorable Radiologic Outcomes after Fusion Surgery in Thoracolumbar Burst Fracture : What Amount of Postoperative Thoracolumbar Kyphosis Correction is Reasonable?

  • Seo, Dong Kwang;Kim, Chung Hwan;Jung, Sang Ku;Kim, Moon Kyu;Choi, Soo Jung;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.96-105
    • /
    • 2019
  • Objective : The aims in the management of thoracolumbar spinal fractures are not only to restore vertebral column stability, but also to obtain acceptable alignment of the thoracolumbar junction (T-L junction) to prevent complications. However, insufficient surgical correction of the thoracolumbar spine would be likely to cause late progression of abnormal kyphosis. Therefore, we identified the surgical factors that affected unfavorable radiologic outcomes of the thoracolumbar spine after surgery. Methods : This study was conducted in a single institution from January 2007 to December 2013. A total of 98 patients with unstable thoracolumbar spine fracture were included. In these patients, fixation was done through transpedicular screws with rods by three surgical patterns. We reviewed digital radiographs and analyzed the images preoperatively and postoperatively during follow-up visits to compare the change of the thoracolumbar Cobb angle with radiologic parameters and clinical outcomes. The unfavorable radiologic group was defined as the patients who were measured as having greater than 20 degrees of thoracolumbar Cobb angle on the last follow-up, or who underwent kyphotic progression of thoracolumbar Cobb angle greater than 10 degrees from the immediate postoperative state to final follow-up, or who had overt instrument failure with/without additional surgery. We assessed the risk factors that affected the unfavorable radiologic outcomes. Results : We had 43 patients with unfavorable radiologic outcomes, including 35 abnormal thoracolumbar alignments and 14 instrumental failures with/without additional surgery. The multivariate logistic regression test showed that immediate postoperative T-L junction Cobb angle less than 10.5 degrees was a statistically significant risk factor, as well as the presence of osteoporosis (p=0.017 and 0.049, respectively). Conclusion : Insufficient correction of thoracolumbar kyphosis was considered to be a major factor of an unfavorable radiological outcome. The spinal surgeon should consider that having a T-L junction Cobb angle larger than 10.5 degrees immediately after surgery could result in an unfavorable radiological outcome, which is related to a poor clinical outcome.