• Title/Summary/Keyword: Verification fimls

Search Result 2, Processing Time 0.014 seconds

The analysis of radiatin field accuracy in uterine cervical cancer patients using verification films. (조사야 확인용 film을 이용한 자궁 경부암 환자의 조사야 정확성 연구)

  • Jung Hee-Young;Kweon Young-Ho;Jeong Deok-Yang;Whang Woong-Ku;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.133-145
    • /
    • 1995
  • 1. Purpose : 30 patients with uterine cervical cancer who had been treated at Department of radiation Oncology of Korea university Hospital from June, 1, 1994. to December. 31, 1994. were analyzed to the radiation field accuracy using verification films. 2. Methods and Materials : 30 patients were divided by 6 groups, 5 patients respectively : Group (1) : Standard physique, supine not-fixed Group (2) : Standard physique, supine fixed Group (3) : Obesity physique, supine, not-fixed Group (4) : Obesity physique, supine, not-fixed Group (5) : Obesity physique, prone, not-fixed Group (6) : Obesity physique, prone, fixed All groups were taken verification fimls during the whole treatment period, and it compared with simulation films and portal fimls, 3. Results : This results suggest that all patients should be immovilized and especially obesity physique patients should be treated by prone position in order to reduce radiation field discrepancy. In addition, this results should help to prescribe appropriate safty margins for patients simulation.

  • PDF

'THE METHOD OF TBI FOR ACCURATE REPRODUCTION OF RADIATION FIELD AND PATIENT POSITION' (방사선 전신 조사 치료시 정확한 환자자세 및 조사야 재현을 위한 방법)

  • KWEON YOUNG-HO;LEE BYOUNG-GOO;WHANG WOONG-KU;KIM YOU-HYUN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.156-166
    • /
    • 1995
  • Total body irradiation (TBI) requires large radiation field and extended source to axis distance (SAD), therefore in needs large size treatment room and it needs compensators which components. Appropriate thickness beam spoiler should be used to raise skin dose. Treatment machine, photon energy, total dose, dose rate, dose fractionation, patient position, shield of normal tissues and organs were known to important parameters for TBI. TBI disturbes regular daily treatment schedule and significantly overloads Radiation on oncology departments and during the treatment session it requires accurate reproduction of radiation field and patient position. We were enable to TBI in small size treatment room and short SAD with parallel opposing lateral fields technique and achieved homogenious whole body dose distribution using pb compensators and controled lung dose by lung shield blocks. Drawing a patient shadow on the wall, we could shortened set up time and possible to accurate reproduction of radiation field and patient position.

  • PDF