• Title/Summary/Keyword: Ventilation rates

Search Result 221, Processing Time 0.027 seconds

간이 농업시설의 환경해석 (Environmental Analyses in Rain Shelters)

  • 손정익
    • 한국농공학회지
    • /
    • 제38권3호
    • /
    • pp.41-49
    • /
    • 1996
  • One of the typically simple structures in protected horticulture is the rain shelter, which is widely applied in summer regardless of its poor ventilation. To evaluate ventilation performance of rain shelters, the ventilation rate as well as inside temperature of one conventional and two improved rain shelters were predicted and compared under various wind speeds and irradiations. More accurate model in which the inside space of rain shelter was subdivided into three parts considering the crops grown, was developed. The ventilation rate of each opening and the general direction of air flow in the rain shelter can be predicted by the model. The ventilation rates as well as inside temperatures of each rain shelter obtained by the model and the actual measurement, proved that the ventilation performance of improved rain shelters were superior to that of conventional one.

  • PDF

철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 수치연구 (Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires)

  • 장원철;김동운;유홍선;이성혁
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2130-2138
    • /
    • 2008
  • The present study investigates the ventilation effects on smoke spreading characteristics in railway tunnels with the rescue stations. Experiments were carried out for n-heptane pool fires with a square length 4 cm at different fire locations, and the heat release rates (HRR) were obtained by the measurement of burning rates. In addition, using the commercial code (FLUENT), the present article presents numerical results for smoke behavior in railway tunnels with rescue station, and it uses the MVHS (Modified Volumetric Heat Source) model for estimation of combustion products resulting from the fire source determined from the HRR measurement. As a result, it is found that smoke propagation is prevented successfully by the fire doors located inside the cross-passages and especially, the smoke behavior in the accident tunnel can be controlled through the ventilation system because of substantial change in smoke flow direction in the cross-passages.

  • PDF

DMF를 사용하는 합성피혁 공장 인쇄공정의 산업환기시스템 평가 및 개선 (A Valuation and Improvement of Industrial Ventilation System of Printing Process in Synthetic Leather Factory using Dimethylformamide)

  • 이선우;김태형;김정만;김종철
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.113-126
    • /
    • 2009
  • In the recent years, health effect of dimethylformamide(DMF) has been one of critical industrial hygiene issues. There might be many factors to increase the exposure level of DMF. Among those factors, industrial ventilation would be one of the main factors. In this study, industrial ventilation systems of printing processes in synthetic leather factories were thoroughly surveyed and the improved ventilation systems were proposed. 7 synthetic leather factories were selected for this study. After the ventilation systems were visually inspected, each component of the system was tested by using the appropriate instruments. Hood face velocities, fan exhaust flow rates, fan static pressures, fan rotation rates, etc were measured. In addition, flow visualization techniques were used to observe flow patten around hoods and inside the factory buildings. After gathering all qualitative and quantitative information, the test results were analysed to see if any improvement might be necessary. For the system to be improved, the re-design plans were made by using computational fluid dynamics softwares. The softwares used in this study were AIRPAK and STAR-CD. The effectiveness of the several improvement options were tested, then the best cost effective option was selected. Finally, the standard ventilation systems were proposed to minimize the exposure levels of DMF.

무창산란계사의 환경분석에 관한 연구 (Environmental Analysis in the Windowless Laying Hen Houses)

  • 이성현
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.225-230
    • /
    • 2003
  • This study was carried out to analyze the environmental variation of layer house at Iowa State in the USA. The analyzed seasons for this study were summer and winter. Analyzing factors are inside temperature and relative humidity, carbon dioxide concentration, ammonia concentration and emission. All factors were collected every 30 second from each house with portable monitoring units. In this study, two types of laying hen houses were monitored at the same season. One was a manure belt house, the other was a high-rise house. In order to estimate the ventilation rates of the laying hen houses, carbon dioxide concentration balance was used in this study. Ammonia concentrations and emission rates of the manure belt house are much lower than those of the high rise house. Daily mean ammonia concentrations in the manure belt house and high-rise house ranged from 3 to 7 ppm and 5 to 34 ppm, respectively. The daily ammonia emission rates averaged 0.68g/h$\cdot$500kg and 0.73g/h$\cdot$500kg for the manure belt house and 0.93g/h$\cdot$500kg and 2.89g/h$\cdot$500kg for the high-rise house in summertime and wintertime, respectively. Summertime is associated with much higher ammonia emission rates than wintertime because of much higher ventilation rates and ambient air temperature, even though the concentrations may be lower.

유츨 허브를 갖는 HDD내 동시회전디스크 표면에서의 열전달 및 유동특성 해석 (Heat Transfer and Flow Characteristics on Co-rotating Disks with a Ventilation Hub in Hard Disk Drive)

  • 조형희;원정호;류구영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.382-389
    • /
    • 2001
  • In the present study, local heat transfer rates for co-rotating disks with two modified hubs having ventilation holes are investigated for Rossby number of 0.04, 0.1 and 0.35 to evaluate the influence of incoming flows through hub holes. A naphthalene sublimation technique is employed to determine the detailed local heat/mass transfer coefficients on the rotating disks using the heat and mass transfer analogy. Flow field measurements are conducted using Laser Doppler Anemometry (LDA) and numerical calculations are performed simultaneously to analyze the flow patterns induced by the disk rotation. The basic flow structure in a cavity between co-rotating disks consists of three regions; the solid-body rotating inner region, the outer region with turbulence vortices and the shroud boundary layer region. The heat/mass transfer. rates on the co-rotating disks are very low near the hub due to the solid-body rotation and those increase rapidly in the outer region due to turbulence mixing. The modified hubs with ventilation holes enhances significantly the heat/mass transfer rates on the region near the hub. The results also show that the heat transfer of Hub-2 is superior to that of Hub-1, but Hub-1 is more profitable for destructing the solid-body rotating inner region.

  • PDF

초·중·고등학교의 이산화탄소 농도 및 환기량 평가 (Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools)

  • 최영태;허정;박진현;김은채;류현수;김동준;조만수;이채관;이종대;양원호
    • 한국환경보건학회지
    • /
    • 제46권3호
    • /
    • pp.344-352
    • /
    • 2020
  • Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

Removal of Serratia marcescens Aerosols Using an Electrostatic Precipitator Air-Cleaner

  • Ko, Gwang-Pyo;Burge, Harriet
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권10호
    • /
    • pp.1622-1628
    • /
    • 2007
  • We characterized the efficacy of an electrostatic precipitator (ESP) air-cleaner in reducing the concentration of Serratia marcescens in an enclosed space. We used an experimental room ($4.5{\times}3{\times}2.9\;m$) in which electrostatic air-cleaners were located. Two air-cleaners enhanced the equivalent ventilation rates in the chamber by about 3.3 air changes per hour (ACH) over the 2 ACH provided by the mechanical ventilation system. Natural die-off of the organisms provided an additional equivalent of 3 ACH, so that the total ventilation rate with the ESP air-ccleaners was 8.3 ACH. We also examined whether the ESP air-cleaners altered the deposition of Serratia marcescens aerosols on the experimental room surfaces. We did not find any significant differences in the number of colony forming units recovered from surfaces with and without the air-cleaners. We installed UV lights inside the ESPs and determined if UV light, in addition to electrical fields, increased the efficacy of the ESPs. The presence of UV light inside the ESP reduced S. marcescens aerosols by approximately 2 ACH. Finally, a box model indicates that the efficiency of the air-cleaner increases for both biological and nonbiological particles at ventilation rates of 0.2-1, which are typical for residential settings.

초보자에서 마네킨에게 직접 후두경과 삽관용 후두마스크기도기를 이용한 기관내삽관의 비교 (Comparison of tracheal intubation using the Macintosh laryngoscope versus the intubating laryngeal mask airway in novice users - A manikin study -)

  • 황지영;조근자
    • 한국응급구조학회지
    • /
    • 제16권2호
    • /
    • pp.75-89
    • /
    • 2012
  • Purpose : This research was designed to provide basic data for advanced pre-hospital airway management by comparing the time to ventilation and success rate for tracheal intubation performed with Macintosh laryngoscope and intubating Laryngeal Mask Airway(ILMA) in a manikin. Methods : All participants were novice users among EMT-Paramedic students and were divided into two groups: (1) the group for Macintosh laryngoscope guided tracheal intubation(MLG-TI) (2) the group for ILMA guided tracheal intubation(ILMA-TI). After an introductory lecture and demonstration, each group made an attempt ten tracheal intubation to compare the ventilation time and success rate for tracheal intubation. Results : 1) There was significant difference in the time to ventilation through MLG-TI, the time to first and second ventilation through ILMA-TI of the 10 attempts. 2) The time to first ventilation through ILMA-TI was significantly shorter than that of ventilation through MLG-TI. 3) There was no significant difference between the time to ventilation through MLG-TI and the time to second ventilation through ILMA-TI. 4) The success rates of ILMA-TI were significantly higher than those of MLG-TI. Conclusion : ILMA-TI can be an alternative method for MLG-TI in advanced pre-hospital airway management.

난류유동해석을 통한 환기효율의 수치해석적 연구 (Numerical Analysis of Ventilation Effectiveness using Turbulent Airflow Modeling)

  • 한화택
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.253-262
    • /
    • 1992
  • A numerical procedure is introduced to calculate local ventilation effectiveness using the definitions of local decay rate and local mean age. A low Reynolds number $k-{\varepsilon}$ model is implemented to calculate steady state turbulent velocity distributions, and a step-down method is used to calculate transient concentration distributions. Simulations are carried out for several different values of air change rates and several different diffuser angles in a two-dimensional model of a half scale office room. The results show that the local ventilation effectiveness within a room could vary significantly from one location to another. The nominal air change rate based on the assumption of complete mixing of room air does not provide the local ventilation effectiveness information. It is numerically proved that the local mean age distribution obtained from the transient calculation is equivalent to the steady state concentration distribution with homogeneously distributed contaminant sources.

  • PDF

겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 - (Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling -)

  • 이재석;한충수;함택모;연광석
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.