• 제목/요약/키워드: Ventilation condition

검색결과 444건 처리시간 0.021초

지하건설공사의 작업환경 개선에 관한 연구 -환기와 조명을 중심으로- (A Study on the improvement of working condition in the downtown Underground construction - Focused on the Ventilation and Lighting -)

  • 고성석;안홍섭
    • 한국안전학회지
    • /
    • 제12권2호
    • /
    • pp.119-132
    • /
    • 1997
  • According to the construction environmental changes due to the trend of large scale and complicated building construction, many construction methods(such as : TOPDOWN )are more often used. However, it is pointed out that occupational pulmonary diseases, reduction of the machinery lifetime and productivity caused to be narrow visual field and collision between the workers. Therefore, this study is mainly dealing with the views of productivity and safety improvement in order to improve work efficiency and to insure the safety in underground construction environment.

  • PDF

대구지역의 국지순환풍의 환기경로 및 대기오염수송에 관한 수치모의 (Numerical Simulation on the Wind Ventilation Lane and Air Pollutants Transport due to Local Circulation Winds in Daegu Districts)

  • 구현숙;김해동
    • 한국지구과학회지
    • /
    • 제25권6호
    • /
    • pp.418-427
    • /
    • 2004
  • 최근 도시기후를 고려한 도시계획이 많은 나라에서 실용화되고 있다. 도시기후의 고려는 주로 도시의 바람 길 조성이라는 개념으로 구체화되고 있다. 도시의 바람 길 조성은 주로 하계에 도시지역의 열적 쾌적성을 개선하는 것을 목표로 한다. 아울러, 과학적 조사에 근거하여 도시의 단지계획을 합리적으로 함으로써 청정한 냉기류의 도심유입을 원활히 하여 도심의 대기오염을 저감하고자 하는 것도 목적으로 한다. 이 연구에서는, 수치실험을 통하여 전형적인 난후기일을 대상으로 대구지역의 국지순환풍이 지나는 바람의 길을 조사하였다. 그리고 이 바람에 의한 대기오염의 수송도 조사하였다. 수치실험에 사용한 모형은 RAMS(지역규모 대기모델)이다. 수치실험의 관심지역은 대구광역시 일대(약900$km^2$)이다. 수평규모는 약 30km이다. 수치실험은 일반풍이 약하고 쾌청한 일기조건을 갖는 늦봄의 기상조건 하에서 수행되었다. 수치실험의 결과 다음과 같은 3가지 결과를 얻었다: (1) 대구의 대표적 산지인 팔공산과 앞산에서 야간에 산정에서 복사냉각으로 생성된 국지풍이 지나는 길을 발견할 수 있었다. 그 바람은 대구의 동쪽 지역에서 중력류의 형태로 계곡을 따라서 흘러내렸다. (2) 평지에서는, 그 바람이 대구의 중심지를 지나 서쪽으로 흘러갔다. (3) 그 결과로, 대기오염물질은 야간에 국지풍에 의해 서쪽지역으로 수송되어졌다.

광산 통기수갱발파에서 전색조건이 발파효율에 미치는 영향에 관한 수치해석적 연구 (Numerical Analysis on Effect of Stemming Condition in Mine Ventilation Shaft Blasting)

  • 김준하;김정규;정승원;고영훈;;김종관
    • 화약ㆍ발파
    • /
    • 제39권3호
    • /
    • pp.15-23
    • /
    • 2021
  • 통기 수갱은 지하공간 개발시 분진 또는 매연 등을 제거하기 위해 광산과 터널에서 사용되는 통로이다. 광산에서는 통기 수갱 개발을 위해 10~20m 구간의 크라운필라 영역을 1회의 장공발파로 굴착하는 공법이 적용 가능하다. 이 경우 천공오차를 파악하기 위해 장약공을 완전히 천공하였을 때 장약공 하부가 구속되지 않으며, 또한 이는 폭약 장약과 발파효율을 떨어트리는 문제를 발생시킨다. 이는 장약공 하부에 전색을 사용함으로 장약공 하부를 전색하여 폭약 장약의 문제를 해결하고 발파효율을 증가시킬 수 있다. 본 연구에서는 ANSYS AUTODYN 2D SPH(Smooth particle hydrodynamics) 해석기법을 이용하여 장약공 직경(45, 76mm)과 다양한 전색장을 달리한 통기 수갱 발파 시뮬레이션을 실시하였다. 또한 발파에 따른 하부의 대괴 사이즈, 저항선을 확인하여 최적의 하부전색장을 도출하였다. 해석 결과 하부전색장 30cm 이하의 경우 발파효율이 저하되며, 발파효율을 높이기 위해서 30cm 이상의 전색장을 적용하여야 함을 확인하였다.

지하철 화재시 본선터널 환기시스템에 따른 열 및 연기배출특성 (A Study of Heat St Smoke Evacuation Characteristics by the Changing of Operational Method of Tunnel Fan Shaft Ventilation System for Fire on Subway Train Vehicle)

  • 이동호;유지오
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.62-69
    • /
    • 2003
  • 국내의 경우, 지하철 승강장 제연설비는 전용설비로 구축되어 있지 않고 화재발생시 승강장환기설비 및 본선터널부의 환기설비를 제연모드로 절환하여 운영되고 있다. 제연효과는 이러한 까닭으로 환기설비의 위치, 용량 및 급배기방식에 종속된다. 따라서 본 연구는 승강장에 정차한 열차에서 화재가 발생하는 경우를 대상으로 승객의 대피 소요시간을 산출하고 지하철환경해석 프로그램인 SES(Subway Environmental Simulation)를 사용하여 터널부 환기설비의 제연절환운전으로 승강장부에 형성되는 기류의 해석 및 FDS(Fire dynamics Simulator)을 이용하여 화재해석을 제연방식별로 수행한다. 얻어진 가시도 및 승강장 의 온도로부터 본선 터널부 제연모드별 특성을 규명한다.

차량 운전자의 공기오염물질 잠재적 노출 및 차량용 공기청정기에 의한 제어 (Potential Exposure to Air Pollutants for Driver and Its Control Using Commercial Air Cleaning Device Inside Vehicle)

  • 김대원;김문현;양원호
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.481-486
    • /
    • 2004
  • Vehicle occupant exposure to air pollutants has been a subject of concern in recent years because of higher levels of air pollutants inside gasoline or diesel-using vehicle, comparing to the surrounding atmosphere. Contrary to previous studies, fuel of vehicles operated in this study was liquefied petroleum gas (LPG). This study examined the potential exposure and removal efficiency of selected volatile organic compounds (VOCs), nitrogen dioxide ($NO_2$) and respirable suspended particle (RSP) by commercial air cleaning device inside vehicle under different ventilation conditions. Vehicle concentrations inside of benzene, toluene, m,p-xylene, $NO_2$ and RSP were lower under the low ventilation condition. This was indicated that outdoor air pollutants could affect the vehicle air quality inside in case metropolitan cities such as Daegu. The urban vehicle concentrations inside of benzene, toluene, m,p-xylene, $NO_2$ and RSP with air cleaning device were higher than those without air cleaning device. This means that the use of air cleaning device equipped with activated carbon filter, which was used in this study, in the interior of vehicles could be expected to reduce the vehicle occupants exposure to air pollutants effectively. In batch type reactor of laboratory scale, removal efficiencies of air cleaning device used were $97.0\%,\;95.7\%,\;94.6\%\;and\;85.5\%$ respectively in benzene, toluene, m,p-xylene and $NO_2$.

폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구 (A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System)

  • 곽경민;배철호;김지용;주의성
    • 청정기술
    • /
    • 제13권4호
    • /
    • pp.281-286
    • /
    • 2007
  • 본 연구에서는 폐열회수형 환기장치(전열교환기)로부터의 휘발성 유기화합물이 측정되었다. KS 냉방 및 난방표준조건하에서 휘발성유기화합물의 초기 배출특성을 연구하기 위하여 폐열회수 환기장치로부터 2종류의 열교환소자(L형과 M형)가 평가되었다. 휘발성 유기화합물은 다양한 풍량 변화와 운전시간 변화에 대하여 측정되었다. 본 연구의 분석방법 및 기기상의 한계로 인하여 농도가 비교적 큰 물질만을 살펴보니 페열회수 환기장치에서는 acetic acid, 2-butanone (MEK), 2-(methylthio)ethylamine, toluene, styrene 및 x-acids (Ion 57) 등의 6종의 휘발성 유기화합물이 배출됨을 확인하였다. 배출된 휘발성 유기화합물의 농도는 운전조건에 대해서는 크게 영향을 받지 않았다. 높은 작동온도 때문에 휘발성 유기화합물의 농도는 난방조건보다는 냉방조건에서 더 크게 나타났다.

  • PDF

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

Characterization of Fruitbody Morphology on Various Environmental Conditions in Pleurotus ostreatus

  • Jang, Kab-Yeul;Jhune, Chang-Sung;Park, Jeong-Sik;Cho, Soo-Muk;Weon, Hang-Yeon;Cheong, Jong-Chun;Choi, Sun-Gyu;Sung, Jae-Mo
    • Mycobiology
    • /
    • 제31권3호
    • /
    • pp.145-150
    • /
    • 2003
  • This study investigated the morphological differences of P. ostreatus grown in the artificial environmental conditions such as humidity, temperature, ventilation, and watering. Oyster mushroom, which was cultivated on artificial environmental condition, was shown to have different morphology of fruitbodies. The optimum $CO_2$ concentration for good morphology of P.ostreatus was 0.3%. But most fruitbody showed the morphologically low qualities in more than 0.5% of $CO_2$ concentration. In the humidity in excess of 80% at $13{\sim}16^{\circ}C$, the best morphology of P. ostreatus was investigated. The growth of fruitbodies of P. ostreatus in the ventilation system was good at the wind velocity ranging from $0.2{\sim}0.5$ fpms and expouring type. In other conditions, P. ostreatus generally showed the morphology closing to malformation.

오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획 (Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations)

  • 김지영;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

공동주택에서 취침 시 실내공기환경 평가에 관한 연구 (A Study on the Assessment of the IAQ during Nightime)

  • 김동규;김삼열;김세환
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.