• 제목/요약/키워드: Ventilation Fan

검색결과 279건 처리시간 0.021초

급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구 (A Study on the Reaching Time of Setting Temperature with Ventilation Air)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

에어컨 실외기 풍량증가를 통한 성능 향상 및 상대적 원가절감 (Improved Performance Through Air Conditioner Outdoor Fan Airflow Increase and Relative Cost Reduction)

  • 김재열;최승현;김성현;기석호;윤성운
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.570-574
    • /
    • 2012
  • Spread of household air conditioning system is continued to be increased. Axial fan in the external unit of air conditioning system is for ventilation and air supplying unit, and the related products have been widely adopted as household electronics, automobile engine, big sized blower in factory, tunnel, and subway. In this study, commercial 3-winged propeller fan is modified to shape and modified to 2-winged fan for the airflow increase and cost reduction. Using 3D modelling, the fan shape is modified, and analysis flow is adopted to provide the way to airflow increase and reduce cost while maintaining the same wind capacity.

화력발전용 보일러의 맥동 측정 장치 (Apparatus for Measuring Fan Stall of Boiler for Power Station)

  • 조현섭
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1681-1684
    • /
    • 2014
  • 본 논문에서는 석탄화력 발전소의 보일러에서 통풍계통의 맥동을 실시간으로 측정할 수 있는 장치에 관한 것이다. 500MW급 대용량 보일러 통풍계통의 맥동 감시장치는 팬 이상 발생시 팬을 보호하기 위하여 정지시키는 기능을 한다. 그러나 맥동 감시 장치의 빈번한 고장으로 신뢰성이 저하되고 운전에 영향을 미치므로 이것을 DCS(Distributed Control System) 로직으로 구성하여 신뢰성을 향상시켰다.

취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구 (A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping)

  • 김세환;김동규;박종일
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

침실 공기질 개선을 위한 강제 환기횟수에 관한 연구 (A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment

  • Kim, Hyunjoo;Kim, Jin Seog;Lee, Jongman;Kim, Dalho
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.49-57
    • /
    • 2020
  • Controlling the quality of indoor air is important in order to maintain a healthy life. In this study, we investigated the correlation between the hazardous substance concentration of indoor air and circulation based on different ventilation methods in the apartment, which is one of the representative housing types in Korea. As target substances, we considered the hazardous substances which are generated during the cooking process and radon gas which is originated from building materials. We measured the concentrations of carbon dioxide and fine particles in relation to type of food and ventilation methods in order to determine the change in the concentration levels of hazardous substances which are generated during the cooking process. On the other hand, we measured the concentration of radon gas before and after letting fresh air into a room through windows in order to determine the change in the concentration level of radon gas which is originated from building materials. The results show that turning on the ventilation fan plays a major role in reducing the concentration levels of hazardous substances in the kitchen, and that it is more effective to turn on the ventilation fan during cooking than after cooking to prevent the diffusion of hazardous materials produced by cooking through the indoor air. Also, the results indicate that letting fresh air into a room through windows more than one time a day is necessary to reduce the concentration level of radon gas in the room to safe concentration range.

철도터널 화재시 연결통로 및 대피로 제연을 위한 수치해석 연구 (Numerical Simulation of Smoke Ventilation in Rescue Route and Cross Passage of Railroad Tunnel)

  • 양성진;허남건;유홍선;김동현;장용준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2008
  • A transient 3-D numerical simulation was performed to analyze the fire safety in a railway tunnel equipped with a mechanical ventilation system. The behavior of pollutants was studied for the emergency operation mode of ventilation system in case of fire in the center of the rescue station and near the escape route. Various schemes of escape route construction for connection angle($45^{\circ}$, $90^{\circ}$, 135^{\circ}$) and slope($10^{\circ}$) were evaluated for the ventilation efficiency in the fire near the escape route. From the results, it was shown that the mode of the ventilation fan operation which pressurizes the tunnel not under the fire and ventilates the smoke from the tunnel under the fire is most effective for the smoke control in the tunnel in case of the fire occurrence. It was also shown that the blowing of jet fan from the rescue tunnel to the main tunnel should be in the same direction as the flow direction in the main tunnel arising from the traffic and the buoyancy.