• Title/Summary/Keyword: Vent control

Search Result 84, Processing Time 0.026 seconds

Evaluation of Natural Ventilation Performance for Multi-span Plastic Greenhouses (다연동 플라스틱 온실의 자연환기성능 평가)

  • Nam, Sang-Woon;Kim, Young-Shik;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • Environmental measurements in the many different types of horticultural farms were carried out to evaluate the ventilation performance for multi-span plastic greenhouses according to the eaves height, the number of spans, the existence of side wall vents and the position of roof vents. Hydroponic tomatoes were being cultivated in all experimental greenhouses, and ventilation rates of the greenhouses were analyzed by the heat balance method. It showed that the ventilation rate in the greenhouse with 4 m eaves height increased about 22% compared to the greenhouse with 2 m eaves height. The ventilation rate in the greenhouse with 9 spans decreased about 17% compared to the greenhouse with 5 spans. In the greenhouse with 9 spans, if there were no side wall vents, the ventilation rate showed about a third of the case that side wall vents were open. Overall, as the eaves height was higher and the number of spans was smaller in multi-span greenhouses, the natural ventilation performance was better. And the ventilation performance was best in the greenhouse which the eaves height was high and the position of roof vents was ridge, not gutter. Therefore, in order to maximize the natural ventilation performance, multi-span plastic greenhouses need to improve their structures such as that make the eaves height higher, place the roof vents on the ridge, install the side wall vents as much as possible, and the number of spans is limited to about 10 spans.

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

Development of Multi-span Plastic Greenhouse for Tomato Cultivation (토마토 재배용 연동 플라스틱 온실 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Kim, Young Chul
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.428-436
    • /
    • 2012
  • This study aimed to develop the multi-span plastic greenhouse which is suitable for tomato cultivation and is safe against climatic disasters such as typhoon or heavy snow. The width and heights of eaves and ridge of newly developed tomato greenhouse are 7, 4.5 and 6.5 m, respectively. The width is the same but the eaves and ridge heights are 1.8 and 2 m higher than conventional 1-2 W greenhouses, respectively. Cross beam has been designed as a truss structure so it can sustain loads of tomato and equipment. Tomato greenhouse has been designed according to climatic disaster preventing design standard maintaining the high height. In other words, the material dimensions and interval of materials including column and rafter have been set to stand against $40m{\cdot}s^{-1}$ of wind and 40 cm of snow. Tomato greenhouse has been equipped with rack-pinion type roof vents which have been used in glass greenhouse in order to prevent excessive rise in air temperature. This vent type is different from that of 1-2 W type greenhouse which is made by rolling up and down the vinyl at upper part of column. Roof vents are installed at ridge, and thus external air inflow and natural ventilation are maximized. As the height increases, heating cost increase as well and, therefore, tomato greenhouse has been equipped with multi-layered thermal curtain, of which thermo-keeping is excellent, to prevent heat from escaping.

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

A HISTOLOGIC STUDY OF THE OSSEOINTEGRATION PROCESS TO THE TITANIUM TOOTH ROOT IMPLANT (타이타늄 치근형 매식체에 대한 골유착 과정에 관한 조직학적 연구)

  • Ahn, Chang Young;Kim, Yung Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.1-28
    • /
    • 1990
  • The severe atrophic edentulism with poor neuromuscular control militates against successful conventional denture therapy. To such situation, a prescribing of dental implant treatment has been considered with some probability. Implant materials used as a trial for dental implants includes metals, plastic polymers and ceramics. The purpose of this study was to observe histologic response in osseointegration process at titanium implant-tissue interface based on biocompatibility at specific period of sequential natures which were divided into a half month, one, month, two months, three months and immediate as a base line. In this study, unilateral lower left premolar and molar teeth were extraced in three dogs. After allowing to heal for 6 months, three kinds of osseointegrated implant, $Br{\aa}nemark$, Corevent and kimplant(a prototype of SNU implant study)were inserted in each dog respectively according to the above sequence from front to back. The specimens were taken from those dogs at the same time since implant were inserted quite reverse order of the specified periods, and decalcified and processed for histologic examination for the light microscopy and the electron microscopy. The microscopic histologic findings at the interface between titanium implants and tissue were interpretated as follows : A. Light microscopic findings : a. Immediate : Implant were surrounded by compact bone and spongy bone. Microcrak was observed in the superficial bone tissue. Osteocytes were disappeared and bone lacunae were observed as a vacant space in some parts. In the contacting with the spongy bone, bone trabeculae and bone marrow were in contact with the implant. b. A half Month : Osteoblasts exist as a monolayer in th inner bone trabeculae and do bone additiocn. Osteoblasts&inflammatory cells were observed in some parts. c. One Month : The presence of osteoclasts decreased. Osteoblasts did active bone fromation, and bone marrow was in contact with the implant in the many places. d. Two Months : Bone formation was advanced in comparison with the b and c. The presence of osteoclsts was not observed. e. Three Months : The superficial bone tissue contacted with the implants was entirely composed by the compact bone. B. Electron microscopic findings : a. A half month and one month group : In the parts of the active bone formation, osteoblasts with the well developed endoplasmic reticulum and Golgi apparatus were arranged in the monolayer. In the parts of the bone resorption, ruffled border was well developed and many osteoclasts with the well-developed golgi apparatus, mitochondria, vacuole, vesicle and lysosome were existed. b. Three months group : No osteoblasts were observed in the superficial bone tissue. Bone matrix with collaen fiber was observed. c. No significant dirrerence in the histologic findings was observed in $Br{\aa}nemark$, Core-vent and kimplant.

  • PDF

Effects of Drying Methods Based on Exhaust Cycle and Time on the Quality and Drying of Red Peppers

  • Nam, Sang Heon;Ha, Yu Shin;Kim, Tae Wook
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.101-110
    • /
    • 2014
  • Purpose: The purpose of this study is to develop a system to optimize drying potential energy of the exhausted hot air by changing relative humidity of the air. This study modified the conventional drying method into a drying method changing exhaust cycle and time in order to control the relative humidity of the exhausted hot air during drying process. Method: A valve on the vent was controlled according to a preset time to change the exhaust cycle and time. This study analyzed the influence of the two different types of drying method on the drying characteristics, required energy, and quality of the dried peppers: conventional drying method exhausting hot air continuously and new drying method controlling exhaust cycle and time. Results: Drying characteristics based on exhaust time showed that drying time increased with exhaust time, and specific energy consumption was reduced by 28% from 18.39 MJ/kg (conventional method) to 13.24 MJ/kg when exhaust time was set to one minute. Drying characteristics based on heating time showed that drying time increased with heating time and specific energy consumption was reduced by 30% from 18.39 MJ/kg (conventional method) to 12.87 MJ/kg when exhaust time was set to 22 minutes. Drying characteristics based on exhaust cycle showed that drying time increased with exhaust cycle, and specific energy consumption was reduced by 31% from 18.39 MJ/kg (conventional method) to 12.69 MJ/kg when exhaust time was set to one minute and exhaust cycle was set to 22 minutes before drying and 40 minutes after drying. The quality of the dried red peppers showed that capsaicin, color, and sugar content were high as 34.87 mg/100g, 66.33, and 11.87%, respectively, when exhaust time was set to one minute and exhaust cycle was set to 22 minutes before drying and 40 minutes after drying. Conclusions: In order to utilize the drying potential energy of the exhausted air during drying process, the conventional drying method was modified into the drying method controlling exhaust cycle and time. The results showed that drying with exhaust cycle of one minute was more efficient in terms of drying time, required energy, and quality of the dried peppers than the one with exhaust cycle of 20~40 minutes.

Analysis on the installation criteria and ventilation effect for round roof windows in single-span plastic greenhouses (단동 플라스틱 온실의 천창 환기효과와 설치기준 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Ko, Gi-Hyuk;Sung, In-Mo
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.2
    • /
    • pp.271-277
    • /
    • 2012
  • Dimensions, operation conditions and improvement items for round roof windows were investigated in arch shape single-span plastic greenhouse with roof vents, and natural ventilation performance was analyzed based on the ventilation theory. Diameter of round roof windows was mostly 60 cm, and chimney height projected on roof was average 30 cm. Installation space was mostly 5 to 6 m but farmhouse of 10 m and over was 16.7% also. A round roof window which has 60 cm diameter was installed to 6 m space generally and 80 cm diameter was installed to 10 m space, but correct standards did not exist. There were a lot of opinions that ventilation effect of round roof windows is fairly good and user satisfaction is generally excellent. It is problem that there is few effects in summer and that vinyl around each vent tears well and rainwater leaks, and improvement hope item required development of automatic control system. In the wind speed of 0.3 m/s, it was estimated that natural ventilation rates were 0.69, 0.55, 0.50 and 0.48 volumes per minute in case of 2, 4, 6 and 8 m installation space for round roof windows, respectively. It was analyzed that the ratio of ventilation due to buoyancy out of total ventilation were 65.2, 41.9, 29.9 and 22.8% in case of 2, 4, 6 and 8m installation space, respectively. By the round roof windows installed at space of 6 m, ventilation rate was estimated to 0.5 volumes per minute, and we can expect the increase in ventilation rate of 30%. In order to meet the recommended ventilation rate for summer season, we have to install the round roof windows at space of 1 to 2 m. However, it is difficult to apply those installation space because of falling productivity due to lower light transmittance as well as rising costs. It is estimated that the installation space of 6m is appropriate for spring or fall season. Therefore it is necessary to encourage installing the roof windows in single-span plastic greenhouses.

Development of the Safety Cabinet for Respiratory High-Pressure cylinder according to Consequence Analysis of Physical Explosion Damage (호흡용 고압용기 파열 피해영향 분석에 따른 안전충전함 개발)

  • Jang, Kap Man;Kim, Jeong Hwan;Jang, Yu Ri;Lee, Jin Han;Jo, Young Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.80-88
    • /
    • 2016
  • A fire station and scuba have operated filling facilities for respiratory high-pressure cylinder without getting authority or reporting according to High-Pressure Gas Safety Control Act. They need facility improvement and special management to make provision for the time of accident during filling process. The Government have strived to correct illegal operations and suggested an alternative, establishing and operating the safety cabinet. It insures a safety being distance from danger caused by overpressure and a safety provoked by the protective wall equals or superiors. The safety cabinet is required to have an internal structure that smoothly distribute overpressure at the time of rupture. Plus, it needs to minimize fragments. It is also equipped with the performance of protective wall that makes overpressure to outside vent on the place where there is no person (top or bottom). This study calculated the consequence of physical explosion damage and built a prototype of safety cabinet. In addition, through the gas burst test, it derives for the ways to mitigate the physical explosion damage.

건물의 배수 및 통기시스템: 배관 내부압력의 능동적인 제어

  • Gormly, Michael;Swaffield, John. A.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.9
    • /
    • pp.41-51
    • /
    • 2010
  • 건물의 배수 및 통기시스템에서 나타나는 현상중에 확실한 내용이 아직 밝혀지지 않은 부분이 몇 가지 남아 있다. 이것은 19세기 말엽의 근대 위생공학의 시작 단계에서부터 잘 알려진 사실이다. 건물의 배수 및 통기시스템 운용에 대한 내용은 일반 공학과 특정 유체역학의 범위 내에서 가장 잘 이해할 수 있다. 건물의 배수 및 통기시스템의 운영에 종사했던 초기의 기술진들은 이러한 점을 잘 알고 있었으며 유체역학에 적합하게 응용한 많은 사례를 확인할 수 있었다. 제2차 세계대전이 끝나고 이에 대한 많은 연구가 진행되어 왔으며 특히 유럽에서 시작된 전후 재건 붐을 통해 배수 및 통기시스템의 설계에 좀 더 효율적인 접근이 진척되게 되었다. 이러한 배수시스템의 중심에는 배수관 내부의 오염된 공기가 배수구 또는 위생기구를 통하여 주거 공간으로 유입되는 것을 방지하는 트랩(Water Trap)이 있다. 배수트랩의 주요 기능인 봉수는 일반적으로 깊이가 40 mm에서 50 mm 정도로 위생기구의 종류에 따라 봉수의 깊이는 다소 차이가 있다. 배수관내 공기의 흐름이 중요한 것처럼 트랩의 봉수 메커니즘이 중요하기 때문에 이 메커니즘을 소홀히 여긴다면 안전한 배수시스템의 운영을 기대하기는 어렵다. 배수관 내의 공기의 흐름은 배수에 의해 유입되거나 또는 배출된다. 배수관에서 내부 압력의 불규칙한 변화로 인하여 야기되는 불안정한 배수의 흐름은 트랩의 봉수를 파괴하고 나아가 주거공간으로 오염된 공기가 새어 나갈 수 있는 통로를 제공하게 된다. 관내압력의 천이는 이로 인한 문제가 발생할 가능성이 있는 위치에 그 압력을 완화할 수 있는 장치를 설계단계에 반영하여 적용함으로써 제어할 수 있다. 건물 내부에 상당한 길이의 통기배관을 설치하는 것은 배관의 마찰손실로 인하여 천이 현상을 효과적으로 제어할 수 있는 확실한 방법이 되지는 못한다. 그렇지만 통기밸브를 설치하는 것과 같이 배수관 내로 공기를 공급해주는 유입구를 건물 내부에 분산 설치하는 것이 효율적인 통기방식이 될 수 있고, 정압 천이로 인한 위험을 줄여줄 수 있다. 통기밸브는 정압 발생의 원인이 되지 않으며 단지 정압에 반응하여 더욱 기밀하게 닫히며, 약화된 압력파를 반사할 뿐이다. 고층 건물에서 배수입상관과 평행하게 설치된 통기입상관(Parallel Vent Pipe)의 경우 극히 일부분의 정압 천이 현상을 완화할 수 있다. (통기 배관의 직경이 배수 입상배관과 동일한 경우 대략 1/3 정도임), 그러므로 정압의 천이로 인한 압력 파동은 배수 시스템의 나머지 부분을 통해 전파되어 배수 트랩에 영향을 미치게 된다. 정압의 천이가 예상되는 위치에 정압천이 완화 장치(Positive Air Pressure Transient Alleviation Device)를 사용하면 배관 내부압력의 급격한 상승을 방지하여 연결된 트랩의 봉수를 보호할 수 있다. 이렇게 되면 순간적으로 발생하는 배관내 압력의 급등 현상을 90% 정도까지 완화 시킬 수 있다. 경험적으로 배수시스템에서 배관이 완전하게 막혀 과도한 정압이 발생하는 경우는 거의 없다. 이러한 경우에는 가장 낮은 위치에 있는 배수 트랩의 봉수가 깨지면서 자연스럽게 배수시스템의 압력이 해소되게 된다. 이러한 사례는 통기 방식과 상관없이 발생할 수 있다. 실제와 유사한 시뮬레이션을 통하여 통기 밸브(Air Admittance Valves)는 전면 통기 시스템 (Fully Vented System)에서 최소한 트랩의 봉수 보호용으로 적합한 것이 확인 되었다. 어떤 경우 에는 고층 건물에 더욱 적합하다는 것을 확인할 수 있었다. 부압 해소용으로 통기밸브를 이용하고 정압완화용으로 정압 완화장치(PAPAs: Positive Air Pressure Transient Attenuators)를 사용하는 전면적 능동 제어시스템(Fully Engineered Designed Active Control System)이 사용자에게 육안으로는 확인하지 못하는 기능을 보장하면서 배수 시스템의 안전과 효율성에 대한 효과적인 방법을 제공하고 있다.

  • PDF

Ventilation Effect of the Greenhouse with Folding Panel Type Windows (패널굴절방식 환기창 온실의 환기효과)

  • Kim, Jin-Young;Lee, Si-Young;Kim, Hyun-Hwan;Chun, Hee;Yun, In-Hak
    • Journal of Bio-Environment Control
    • /
    • v.11 no.1
    • /
    • pp.5-11
    • /
    • 2002
  • In this study, new development of natural ventilation window was accomplished to control environment of greenhouse with no use of farced ventilation during hot season. The ventilation effect of developed ventilation window was investigated in experimental greenhouse which was designed using side wall panel and folding type panel fur natural ventilation. Folding panel type ventilation window was designed to open upper part of the side wall and top of the roof using two hinges which are located bottom of the side wall and the roof panel to grab one side of each panels and guide the other side along with the guidance rail. Developed ventilation window has top ventilation part with maximum moving distance X=ι (1-cos$\theta$)=848.5 mm and side ventilation part with maximum moving distance Y=ι/2 $\times$sin$\theta$=1,184.4 mm at 45$^{\circ}$ of theoretical opening angle. It took 4.5 minutes to open roof vent fully and temperature at 1.2 and 0.8 m height decreased after 1 minute from starting opening and became equilibrium state maintaining 3-4$^{\circ}C$ difference after 2 minutes from complete opening. Air exchange rate was 15.2~39.3 h$^{-1}$ which was more than 10~15 h$^{-1}$ of continuous type and Venlo type greenhouse. The descent effect of temperature by ventilation windows was two times higher than Venlo type greenhouse.