• Title/Summary/Keyword: Vent Analysis

Search Result 158, Processing Time 0.024 seconds

Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation (CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석)

  • Ha, Jung-Soo;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

Flow visualizations and analysis on characteristics of bubbly flows exhausted from a venturi-type bubble generator with an air vent (공기유입구를 가진 벤츄리 형상의 기포발생기에서 토출되는 기포 유동 특성의 가시화 측정 분석)

  • Bae, Hyunwoo;Lee, Seungmin;Song, Moonsoo;Sung, Jaeyong
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.1
    • /
    • pp.60-68
    • /
    • 2019
  • Flow visualizations have been carried out to analyze the characteristics of bubby flows exhausted from a venturi-type bubble generator with an air vent. For various design parameters and operating conditions of the bubble generator, the images of bubbly flows was recorded using a high-speed camera and a microscope. Then the amount and size distribution of bubble was evaluated by an image processing technique. The results show that for increasing the amount of bubble, it is more effective to reduce the venturi throat than to enlarge the air vent diameter. If the water flow rate increases, the bubble generation rate increases but reaches a status of saturation, whose condition depends on Reynolds number at a given air vent diameter. The bubble size increases as the diameter of venturi throat decreases and Reynolds number increases. However, the air vent diameter is not a significant factor on bubble size.

Evaluation of Thermal Comfort and Cooldown Performance inside Automotive Cabin according to Air-conditioning Vent Location (인체모델을 고려한 자동차 실내의 에어컨 토출구 위치 변화에 따른 냉방성능 및 온열쾌적성 평가)

  • Seo, Jin-Won;Park, Jae-Hong;Choi, Yun-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.120-129
    • /
    • 2012
  • As the recent advancement of automobile industry, there has been a great interest in the thermal comfort of the passengers inside the cabin of an automobile. Thermal comfort is affected by temperature, velocities, and mean radiation temperature of air, thermal resistance of clothes and physical active level of human. The present study performed computational analysis to select the location of air-conditioning vent that improves thermal comfort inside the cabin. In order to do this, we considered various air vent positions, and thermal flow analysis of each case is performed using CFD for the cabin with four passengers. The thermal comfort is evaluated using the computational results and the optimum location of air vent is suggested.

A Study on Improvement of Cooling Performance through Vent Structure Optimization of Carbon Ceramic Composite Disc (카본 세라믹 복합재 디스크의 벤트 구조 최적화를 통한 냉각성능 향상에 관한 연구)

  • Shim, J.H.;Shin, U.H.;Lee, J.H.;Jeon, G.B.;Kim, B.C.;Kwack, J.H.;Lim, D.W.;Hyun, E.J.;Jeon, T.H.;Lee, J.M.
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.1
    • /
    • pp.23-29
    • /
    • 2019
  • Recently, use of composite materials has been increasing for body structures and chassis parts in the car industry because of weight reduction effect and excellent mechanical thermal characteristics. However, application of composite materials in brake system is very difficult because it is hard to obtain enough brake performance due to low heat storage capacity of the composite materials. In this paper, we will present new carbon ceramic composite disc with high flow characteristic. To obtain this characteristic, new vent structures were designed by using ARIZ method and substance-field model analysis. The flow effect of these vent structures on the brake performance was verified by pugh matrix and cooling test. The test results show improvement of cooling performance up to $30^{\circ}C$. Finally, These results will improve brake the reliability of the brake performance for the high performance vehicles and electric vehicles.

Cause of Corrosion and Evaluation of Material Corrosion Resistance on Underground Heat Transport Facilities Connected to Manhole (맨홀과 연결된 지하 열수송설비의 부식 원인 및 재질 내식성 평가)

  • Song, M.J.;Choi, G.;Kim, W.C.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.4
    • /
    • pp.193-202
    • /
    • 2022
  • Manholes and underground spaces are installed to manage the buried heat transport pipes of the district heating system, and the corrosion damage of the equipment placed in this space often occurs. The purpose of this work is to identify locations with a high risk of corrosion damage in the air vent and to establish preventive measures based on precise analysis via sampling of heat transport pipes and air vents that have been used for about 30 years. The residual thickness of the air vent decreased significantly by reaching ~1.1 mm in thickness, and locations of 60~70 mm away from a transport pipe were the most vulnerable to corrosion. The energy dispersive X-ray spectroscopy (EDS) analysis was performed in the corroded oxides, and it was found that chloride ion was contained in the corrosion products. Anodic polarization tests were carried out on the air vent materials (SPPS250, SS304) with varying the amounts of chloride ions at two different temperatures (RT, 80℃). The higher concentration of chloride ions and temperature are, the lower corrosion resistances of both alloys are.

Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent (연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석)

  • Park, Min jung;Choi, Duck kyu;Son, Jin kwan;Yoon, Sung-Wook;Kim, Hee tae;Lee, Seung-Kee;Kang, Dong hyeon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • The objectives of this study were to investigate the standard and roof vent type of multi-span greenhouse and to analyze the characteristics of natural ventilation of multi-span greenhouse with different roof vent using computational fluid dynamics (CFD) code. The vent area proportion of surveyed farms averaged 10%, it was analyzed that the vent design for natural ventilation is insufficient. The results of natural ventilation efficiency of multi-span greenhouse according to roof vent type showed that the temperature of the position in which the crops grew was the lowest in the conical roof vent type and the highest in the half conical roof vent type. For the natural ventilation effect, the conical roof vent type was the best one, but the structural stability should be evaluated in light of wind load.

Corrosion Failure Analysis of Air Vents Installed at Heat Transport Pipe in District Heating System (지역난방수 공급관 에어벤트 부식 파손 분석)

  • Lee, Hyongjoon;Chae, Hobyung;Cho, Jeongmin;Kim, Woo Cheol;Jeong, Joon Cheol;Kim, Heesan;Kim, Jung-Gu;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.189-195
    • /
    • 2020
  • Two air vents situated on a heat transport pipe in district heating system were exposed to the same environment for 10 years. However, one air vent was more corroded than the other. It also had a hole on the top of the front-end pipe. Comparative analysis was performed for these air vents to identify the cause of corrosion and establish countermeasures. Through experimental observation of the damaged part and analyses of powders sampled from air vents, it was found that corrosion was initiated at the top of the front-end pipe. It then spread to the bottom. Energy dispersive X-ray spectroscopy results showed that potassium and chlorine were measured from the corroded product in the damaged air vent derived from rainwater and insulation, respectively. The temperature of the damaged air vent was maintained at 75 ~ 120 ℃ by heating water. Rainwater-soaked insulation around the front-end pipe had been hydrolyzed. Therefore, the damaged air vent was exposed to an environment in which corrosion under insulation could be facilitated. In addition, ion chromatography and inductively coupled plasma measurements indicated that the matrix of the damaged front-end pipe contained a higher manganese content which might have promoted corrosion under insulation.

As tudy on the underwater stability according to the composition of the sea anchor (씨앵커의 구성에 따른 수중 안정성에 관한 연구)

  • Jung-Mo, JUNG;Hyung-Seok, KIM
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.4
    • /
    • pp.289-298
    • /
    • 2022
  • Sea anchor for fishery is commonly used in jigging fishery and purse seine. The study of sea anchor was studied for improvement of opening efficiency and drag by changing the type of shape and the diameter of vent. However, standard specification of sea anchor is not set and has not been studied for underwater stability. Therefore, this study aimed to improve underwater stability of sea anchor by changing a vent diameter and weight of sinker. The experiment was conducted in flume water tank. The experiment model of sea anchor was made from actual model of sea anchor which is used in fishery by similarity law. The model of sea anchor was designed to different types of vent diameter and weight of sinker in different current speed. The value of movement of side to side (X-axis), drag of sea anchor (Y-axis) and movement of up and down (Z-axis) was measured for 30 seconds. Each value of X, Y, Z-axis was analyzed through t-test and ANOVA analysis to verify that each value had a significant difference according to the difference compositions. There was correlation between the movement of X-axis and Z-axis. The drag of sea anchor was stronger as the current speed increased. However, the larger the vent diameter, the weaker the drag. From the result of the standard deviation, the movement of X-axis was inversely proportional to the vent diameter. However, movement of Z-axis was larger as the weight of sinker was the heaviest or lightest from the result of the standard deviation. These results suggest that the sea anchor should be combined with proper size of the vent diameter and the weight of sinker to improve the stability.

Comparison of internal porosity of dental titanium castings with different casting machines (주조방식에 따른 티타늄 주조체의 내부결함 비교)

  • Lee, Kyung-Eun;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.129-140
    • /
    • 2007
  • The purpose of this study was to evaluate the titanium castability (internal porosity) between pressure type casting machine & centrifugal casting machine with air-vent or not. Internal porosity is a well-known problem in dental titanium casting, resulting in inferior mechanical properties of dental restorations. To evaluate the castability, the square plate was chosen. 40 plate patterns($20{\times}20{\times}1.8mm$)were attached to funnel-shaped sprue. Then 20 plate patterns were attached air-vent. They were invested in titanium investment material and cast in a pressure type casting machine(20castings) and centrifugal casting machine(20castings). Each group were divided with air-vent(10castings) or not(10castings). The titanium castings were evaluated by radiographic photograph for the location of the internal porosities. The percentage porosity of each specimen was determined using standardized digital radiographs. The results were analyzed with analysis of variance and t-test for paired comparison between two groups.

  • PDF

Analysis of the High Pressure Die Casting Process by Computer Simulation (수치해석에 의한 고압다이캐스팅용 금형설계 및 주조공정해석)

  • Lee, Chang-Ho;Choi, Jae-Kwon;Nam, Tae-Woon
    • Journal of Korea Foundry Society
    • /
    • v.20 no.6
    • /
    • pp.400-406
    • /
    • 2000
  • Computer simulation for the predictions of casting defects is very important to produce high quality castings with less cost. Complicate shaped Al solenoid housing part was selected to be cold chamber die cast and a numerical simulation technique was applied for the optimization of the chill vent position and gating. A first design led to insufficient central flow. This flow left the last filled areas falling into the inner portion of the part. And last filled area did not fit the chill vent position. So these resulted in a high possibility of air entrapment in the casting and the design was not proper for the part. The design was improved by using a proper gating system, a more chill vent and proper overflow positions. New design provided a homogenous mold filling pattern and the last filled areas that being located at the overflow and chill vent. Casting plan which produce good quality solenoid housing part was established by using the computer simulation.

  • PDF