• Title/Summary/Keyword: Venous

Search Result 1,325, Processing Time 0.027 seconds

Replantation of Nose Amputation by Use of Medical Leech (거머리를 이용한 코 절단의 재접합술)

  • Yim, Youngmin;Kwan, Ho;Oh, Deuk Young;Lee, Ji Yeon;Jung, Sung-No
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.124-130
    • /
    • 2005
  • In the microsurgical era, replantation with microvascular anastomosis is considered as the most superior method in aspects of texture, color, shape in case of nose amputation. There are some reported cases of replantation in nose amputation historically, but most of them are composite graft cases rather than microvascular anastomosis. Only a few cases of successful nasal replantation with microvascular anastomosis have been reported due to the reason that the size of vessels is usually very small and identifying suitable vessels for anastomosis is difficult. Microanastomosis of artery and microanastomosis of vein are ideal in replantation, but identifying suitable veins is often difficult. Without venous anastomosis, resolving the venous congestion remains to be a problem. We can carry out arteriovenous shunt if we can find two arteries in amputee. However, the smaller the size of amputee is, the more difficult it is to find two arteries. Instead of arteriovenous shunt, we can try external venous drainage(frequently swab, pin-prick, stab incision, IV or local heparin injection, dropping, apply of heparin-soaked gauze, use of medical leech). Here, we present three cases of replantation with microscopical arterial anastomosis (one angular artery, two dorsal nasal arteries) and external venous drainage (stab incision, application of medical leech and heparin-soaked gauze) even though the size of amputee may be as small as $1.5{\times}1.0cm$. In all cases, surgical outcomes were excellent in cosmetic and functional aspects. This report describes successful replantation by microvasular anastomosis in case that suitable veins are not found.

Analysis of Relationship between Mixed Venous PO2 and Status of Cardiac Performance with Hemodynamic Values after Correction of Cyanotic Congenital Heart Disease (청색심기형 교정술후 혼합정맥혈 산소분압과 심근상태 및 혈류역학치와의 상관관계 분석)

  • An, Jae-Ho;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.212-219
    • /
    • 1989
  • We utilized pulmonary artery pressure monitoring system in risky patients for preventing the postoperative pulmonary hypertensive crisis and for sampling the mixed venous blood. And this mixed venous blood oxygen saturation [MVSO2] or partial pressure [MVPO2]tells us many meaningful patients state. We selected 59 cyanotic congenital heart diseased patients, who were operated in our hospital from Nov. 1987 to Oct. 1988, in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital, who had pulmonary artery pressure monitoring catheter and who made us know their mixed venous oxygen condition. We found that there was no close relationship between MVPO2 and Cardiac Index [C.I.] during early postoperative period, but on the first and second day after operation the correlation coefficient was increased as r=0.35[p=0.008], r=0.78[p=0.0001]. So we concluded that the correlation between MVPO2 and C.I. was more reliable with time going as hemodynamic stabilization. And we experienced no survivors whose MVPO2 was under 20 torr, but that was not the only factor for death. From these results, we conclude that we can consider the MVPO2 [or MVSO2] representing C.I. after stabilized postoperative condition of the open heart surgery patients, but during early postoperative period, in addition to this MVPO2, we should do also apply other parameter such as urine output, arterial blood pressure, left atrial pressure and pulmonary arterial pressure for exact estimation of the patients status.

  • PDF

Reconstruction of the Superior Vena Cava with Extra-luminal Bypass Shunt (우회단락을 사용한 상대정맥증후군의 수술)

  • Shin Jae Seung;Jo Won-Min;Min Byung Zoo;Chung Won Jae;Lee In Sung
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.68-71
    • /
    • 2006
  • We operated on a 41-year-old man using venous bypass shunt for superior vena cava (SVC) syndrome caused by mediastinal fibrosis. The patient had substantially high venous pressure and high risk of postoperative neurologic deficits. The collateral veins were deemed to be interrupted during the surgical reconstruction of SVC. Treatment included resection of the obstructed SVC and innominate vein and reconstruction with an autologous pericardial tube graft. During the operation, venous drainage from upper body was maintained with an extraluminal bypass shunt. The shunt was effective at prompt relief of venous hypertension, eliminating the time constraints, and preventing the postoperative complications.

Acute and Chronic Isolated Splenic Torsion in Two Dogs (개에서 단독으로 발생한 급성 비장 염전과 만성 비장 염전의 비교)

  • Jung, Joo-Hyun;Chae, Woong-Joo;Chang, Jin-Hwa;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.52-57
    • /
    • 2008
  • An intact male, 3-year old, Sapsari, weighing 29 kg with a history of respiratory distress, anorexia, abdominal distension, and depression for 1 day was referred. Radiographic findings included a C-shaped soft tissue mass in the mid-abdominal cavity and loss of serosal detail. Ultrasonographs showed splenomegaly with hypoechoic coarse parenchyma, loss of venous flow in the dilated splenic veins, and thrombi. Based on image findings, acute isolated splenic torsion was diagnosed. Splenectomy and prophylactic gastropexy was performed. Another case was a spayed female, 8-year old, Shih-tzu, weighing 3.7 kg with a history of intermittent abdominal pain and a palpable abdominal mass for 1 year. Radiographic findings showed splenomegaly characterized by a soft tissue round mass. Ultrasonographs revealed displaced splenic hilum and absence of venous flow in the dilated splenic vein. Chronic isolated splenic torsion was diagnosed and also splenectomy and gastropexy was performed. Two dogs were recovered normally after surgery without any complications. Acute form of isolated splenic torsion showed acute systemic clinical signs, severe C-shaped splenomegaly on radiographs, and loss of all of splenic venous flow, perivenous hyperechoic triangle sign, and thrombi on ultrasonographs. Chronic form of isolated splenic torsion showed chronic obscure clinical signs, moderate splenomegaly on radiographs, and partial loss of splenic venous flow on ultrasonographs.

A Case of Massive Air Embolism after Contrast-enhanced Computed Tomography (조영증강 흉부전산화 단층촬영 후 발생한 대량의 공기 색전증 1예)

  • Park, Byeong Chool;Kil, Ho;Park, Chan Sun;Jeong, Jee In;Choi, Eun Young;Shin, Yoon Mi;Lee, Ki Man;Kim, Sung Jin;Choe, Kang Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.2
    • /
    • pp.178-182
    • /
    • 2007
  • A venous air embolism is a complication of various venous access procedures such as contrast-enhanced computed tomography (CECT). Although most cases of iatrogenic venous air embolisms during CECT involve a few milliliters of air and are asymptomatic, a massive venous air embolism can be fatal. We report a case of a massive intraventricular air embolism after CECT with a review of the literature regarding the pathophysiology and treatment of air embolisms.

Outcomes of Surgery for Total Anomalous Pulmonary Venous Return without Total Circulatory Arrest

  • Lee, Youngok;Cho, Joon Yong;Kwon, O Young;Jang, Woo Sung
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.337-343
    • /
    • 2016
  • Background: Recent developments in surgical techniques and hospital care have led to improved outcomes following total anomalous pulmonary venous return (TAPVR) repair. However, the surgical repair of TAPVR remains associated with a high risk of mortality and need for reoperation. We conducted this retrospective study to evaluate mid-term outcomes following in situ TAPVR repair without total circulatory arrest (TCA), and to identify the risk factors associated with surgical outcomes. Methods: We retrospectively reviewed 29 cases of surgical intervention for TAPVR conducted between April 2000 and July 2015. All patients were newborns or infants who underwent in situ TAPVR repair without TCA. Results: Four anatomic subtypes of TAPVR were included in this study: supracardiac (20 cases, 69.0%), cardiac (4 cases, 13.8%), infracardiac (4 cases, 13.8%), and mixed (1 case, 3.4%). The median follow-up period for all patients was 42.9 months. Two (6.9%) early mortalities occurred, as well as 2 (6.9%) cases of postoperative pulmonary venous obstruction (PVO). Preoperative ventilator care (p=0.027) and preoperative PVO (p=0.002) were found to be independent risk factors for mortality. Conclusion: In situ repair of TAPVR without TCA was associated with encouraging mid-term outcomes. Preoperative ventilator care and preoperative PVO were found to be independent risk factors for mortality associated with TAPVR repair.

Proximal ligation after the side-to-end anastomosis recovery technique for lymphaticovenous anastomosis

  • Suzuki, Yushi;Sakuma, Hisashi;Ihara, Jun;Shimizu, Yusuke
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.344-349
    • /
    • 2019
  • Background Lymphaticovenous anastomosis is an important surgical treatment for lymphedema, with lymphaticovenous side-to-end anastomosis (LVSEA) and lymphaticovenous end-to-end anastomosis being the most frequently performed procedures. However, LVSEA can cause lymphatic flow obstruction because of regurgitation and tension in the anastomosis. In this study, we introduce a novel and simple procedure to overcome this problem. Methods Thirty-five female patients with lower extremity lymphedema who underwent lymphaticovenous anastomosis at our hospital were included in this study. Eighty-five LVSEA procedures were performed, of which 12 resulted in insufficient venous blood flow. For these 12 anastomoses, the proximal lymphatic vessel underwent clipping after the anastomotic procedure and the venous inflow was monitored. Subsequently, the proximal ligation after side-to-end anastomosis recovery (PLASTER) technique, which involves ligating the proximal side of the lymphatic vessel, was applied. A postoperative evaluation was performed using indocyanine green 6 months after surgery. Results Despite the clipping procedure, three of the 12 anastomoses still showed poor venous inflow. Therefore, it was not possible to apply the PLASTER technique in those cases. Among the nine remaining anastomoses in which the PLASTER technique was applied, three (33%) were patent. Conclusions Our findings show that achieving patent anastomosis is challenging when postoperative venous inflow is poor. We achieved good results by performing proximal ligation after LVSEA. Thus, the PLASTER technique is a particularly useful recovery technique when LVSEA does not result in good run-off.

Does the direction of J-tip of the guide-wire influence the misplacement of subclavian catheterization?

  • Kang, Changshin;Cho, Sunguk;Ahn, Hongjoon;Min, Jinhong;Jeong, Wonjoon;Ryu, Seung;Oh, Segwang;Kim, Seunghwan;You, Yeonho;Park, Jungsoo;Lee, Jinwoong;Yoo, Insool;Cho, Yongchul
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.636-640
    • /
    • 2018
  • Objective: Central venous catheter (CVC) misplacement can result in incorrect readings of the central venous pressure, vascular erosion, and intravascular thrombosis. Several studies have examined the correlation between the guidewire J-tip direction and misplacement rate. This study examined whether the guidewire J-tip direction (cephalad vs. caudad) affects the misplacement rate in right subclavian venous catheterization. Methods: This prospective randomized controlled study was conducted between February 2016 and February 2017. The subjects were divided into two groups (cephalad group vs. caudad group) and the misplacement rate was compared according to guidewire J-tip direction in each group. Results: Of 100 patients, the cephalad and caudad groups contained 50 patients each. The age, sex, and operator experience were similar in the two groups. In the cephalad group, misplacement of CVC insertion into the ipsilateral internal jugular vein occurred in two cases. In the caudad group, misplacement of CVC insertion into the contralateral subclavian vein occurred in one case, with loop formation in the brachiocephalic trunk in one case. Guidewire J-tip direction showed no significant correlation with CVC misplacement. Conclusion: The guidewire J-tip direction does not influence the rate of misplacement.

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

Clinical effects of veno-venous extra-corporeal membrane oxygenation for acute myocardial infarction (급성심근경색 환자에게 적용된 정맥-정맥 체외막산화기의 임상 효과)

  • Kim, Su Wan;Seong, Gil Myeong;Lee, Jae-Geun
    • Journal of Medicine and Life Science
    • /
    • v.15 no.2
    • /
    • pp.108-111
    • /
    • 2018
  • Extra-corporeal membrane oxygenation (ECMO) has the potential to rescue patients in cardiac arrest or respiratory failure. ECMO has two systems such as veno-arterial and veno-venous circulation. In cardiac arrest resulting from acute myocardial infarction, veno-arterial ECMO is mandatory for systemic circulation and oxygenation. A 75-year old female patient underwent primary coronary intervention for acute myocardial infarction. Despite successful revascularization, recurrent ventricular tachycardia and heart failure were progressing. We performed a veno-arterial ECMO through the femoral artery and vein, then the patient seemed to be stable clinically. However, laboratory studies, echocardiography, and vital signs indicated multi-organ failure and decreasing cardiac function. We found out an error that we performed veno-venous ECMO instead of veno-arterial ECMO. We added a femoral artery cannula and exchange the circuit system to veno-arterial ECMO. While the systemic circulation seemed to be recovered, the left ventricular function was decreased persistently. A hypovolemia resulting from pulmonary hemorrhage was occurred, which lead to ECMO failure. The patient died of cardiac arrest and multi-organ failure 23 hours after ECMO. Because the color of arterial and venous circuits represent the position and efficacy of ECMO, if unexpected or abnormal circuit colors are detected, prompt and aggressive evaluation for ECMO function is mandatory.