• Title/Summary/Keyword: Vena Cava, Superior

Search Result 135, Processing Time 0.021 seconds

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Type A Aortic Dissection with Aortocaval Fistula -Report of 1 case- (대동맥-상대정맥루를 동반한 A형 대동맥 해리증 수술 치험 -1례보고-)

  • 김흥수;양승인;정성운;김종원;이형렬
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.599-604
    • /
    • 2002
  • Acute or chronic aortic dissection may lead to the rupture, which is the major cause of death. A dissecting aneurysm of ascending aorta(Stanford type A dissection) can rupture into the superior vena cava producing a aortocaval fistula, which is rare, but has been reported mostly in the cases of abdominal aortic aneurysm. We report a case of 67-year-old man with type A chronic dissection and aortocaval fistula, presenting symptoms of superior vena syndrome. The preoperative diagnosis was composed of radiologic examinations, including computed tomography, magnetic resonance imaging angiography and aortography. The dissecting aneurysm was resected and replaced, and the aortocaval fistula was repaired under deep hypothermic circulatory arrest. The details are described here.

Mediastinal Cavernous Hemangioma (상대정맥에 발생한 해면상 혈관종 -1례 보고-)

  • 김동원;이재영;배철영;신원선;맹대현;곽영태;이신영
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.69-72
    • /
    • 1998
  • Mediastinal hemangioma is a rare tumor and only few cases have been reported in the literatures. We have experienced one case of cavernous hemangioma occuring at the superior vena cana. The patient was a thrity-five year old female with no specific symtoms except palpable cystic mass in the right cervical area. A routine chest radiography showed an upper mediastinal mass. Computed Tomography showed about 4$\times$5 cm sized cystic mass communicating to the superior vena cava 2 cm above of the veno-atrial junction. After the evaluation, surgical excision was performed and the pathologic diagnosis was confirmed to cavernous hemangioma. Postoperative course was uneventful and the patient has been followed up without any problems.

  • PDF

Unroofed Coronary Sinus Syndrome with Valvular Disease - Report of A Case - (판막질환을 동반한 관상정맥동 천정결손 증후군 - 수술 치험 1례 -)

  • 박성달
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.162-168
    • /
    • 1990
  • Unroofed coronary sinus syndrome is an uncommon anomaly which is caused by incomplete formation of the left atriovenous fold and it is usually associated with persistent left superior vena cava. It may be diagnosed by cardiac catheterization and cineangiography but, if it is not diagnosed, it can bring out significant complications due to right to left shunt, such as brain abscess, cerebral embolism, transient ischemic attack, arterial desaturation and there will reduced patient`s life expectancy. Therefore corrective operation was needed. A case of unroofed coronary sinus syndrome which combines with valvular heart disease was experienced at the department of thoracic & cardiovascular surgery of Kosin medical college. The patient was 49 years old female and she complained dyspnea on exertion for 2 yrs. Cardiac catheterization with cineangiography and both superior venacavogram were performed for diagnosis and she was diagnosed as unroofed coronary sinus syndrome combined with mitral and tricuspid regurgitation. Surgical correction was accomplished by reroofing of coronary sinus with pericardial patch, closure of atrial septal defect and annuloplasty of both atrioventricular valves. Postoperative results were satisfactory and course of recovery was uneventful. We report a case of unroofed coronary sinus syndrome with review.

  • PDF

Pancoast Syndrome Accompanied by Rotator Cuff Tear

  • Nam, Seung Oh;Shin, Dongju;Park, Kihong;Kim, Tae Kyun;Kim, Han Sang
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.43-46
    • /
    • 2015
  • Pancoast syndrome (PS) is characterized by a malignant neoplasm of the superior sulcus of the lung with destructive lesions of the thoracic inlet and involvement of the brachial plexus and cervical sympathetic nerves. The most common initial symptom of PS is shoulder pain; however, cough, dyspnea, and hemoptysis, signs often associated with lung cancer, are not as common. Investigation of PS can be difficult even with plain radiographs of the chest because it is surrounded by osseous structures such as the ribs, vertebral bodies, and manubrium. Due to these characteristics, orthopedic surgeons tend to make a misdiagnosis resulting in delay of appropriate treatment. Here we report on a patient who was supposed to undergo rotator cuff repair for his shoulder pain and weakness, and was eventually diagnosed with PS.

Fluid Dynamic Efficiency of an Anatomically Correct Total Cavopulmonary Connection: Flow Visualizations and Computational Fluid Dynamic Studies

  • Yun, S.H.;Kim, S.Y.;Kim, Y.H.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.1
    • /
    • pp.11-16
    • /
    • 2004
  • Both flow visualizations and computational fluid dynamics were performed to determine hemodynamics in a total cavopulmonary connection (TCPC) model for surgically correcting congenital heart defects. From magnetic resonance images, an anatomically correct glass model was fabricated to visualize steady flow. The total flow rates were 4, 6 and 8L/min and flow rates from SVC and IVC were 40:60. The flow split ratio between LPA and RPA was varied by 70:30, 60:40 and 50:50. A pressure-based finite-volume software was used to solve steady flow dynamics in TCPC models. Results showed that superior vena cava(SVC) and inferior vena cava(IVC) flow merged directly to the intra-atrial conduit, creating two large vortices. Significant swirl motions were observed in the intra-atrial conduit and pulmonary arteries. Flow collision or swirling flow resulted in energy loss in TCPC models. In addition, a large intra-atrial channel or a sharp bend in TCPC geometries could influence on energy losses. Energy conservation was efficient when flow rates in pulmonary branches were balanced. In order to increase energy efficiency in Fontan operations, it is necessary to remove a flow collision in the intra-atrial channel and a sharp bend in the pulmonary bifurcation.

  • PDF

Application of the New Surgical Technique for Orthotopic Heart Transplantation in Dogs (잡견에 있어서 새로운 심장수술기법의 적용)

  • 원태희;한재진;김기봉;노준량
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.207-211
    • /
    • 2000
  • Backgroud: Conventional cardiac transplantation with each atrial anastomosis designed by Shumway and associates has been used widely in cardiac transplantation because of its simplicity and efficiency. There have been many reports about the postoperative atrioventricular value regurgitation resulting from the alteration in atrial geometry after cardiac transplantation by Shumway's technique. New surgical technique of direct anastomosis of superior vena cava, inferior vena cava, right pulmonary vein and left pulmonary vein was introduced to overcome the those problems. We performed this study to test the feasibility of this new surgical technique prior to application to clinical practice. Material and Method: Conventional cardiac transplantation was performed on 12 mongrel dogs(Group I) and cardiac transplantation with new surgical mthod of direct anastomosis of SVC, IVC, left and right pulmonary veins was performed on 11 mongrel dogs(Group II). After weaning from cardiopulmonary bypass, we compared the postoperative rhythm, hemodynamic data, and echocardiographic findings between two groups. Result : The cardiopulmonary bypass time and graft ischemic time were 119.0$\pm$4.4 minutes, 162.0$\pm$4.5 minutes respectively in group I, and 140.0$\pm$7.1 minutes, 180.5$\pm$5.4 minutes respectively in group II. The cardiopulmonary time and graft ischemic time in group II were longer than those of group I (p<0.05). There were 3 cases of failure to weaning from cardipulmonary bypass onein group I and two in group II, and this difference was not significant statistically. Sinus rhythm was regained postoperatively in 58% (group I) and 82%(group II), without statistical significant between 2 groups. Postoperative echolcardiography showed 2 cases of tricuspid value regurgitation and 1 case of mitral regurgitation in group I, and no regurgitation of atrioventricular value in group II. Conclusion: Although these was no statistically significant difference between 2 groups, there was tendency of less arrhythmia and less atrioventricular valvular regurgitation in group II. We suggested that the new surgical technique could be a useful strategy in heart transplantation, especially in the case of size mismatching between donor and recipient.

  • PDF

Complete Transposition of Great Arteries Combined with VSD and Pulmonic Stenosis (S.D.D.) -One Case Report- (대혈관전위증 (S.D.D.) 치험 1례)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.207-214
    • /
    • 1979
  • This 3-year-old girl was observed frequent exertional dyspnea and cyanosis at crying since birth. She was not premature baby and delivered at full term normally. On physical examination, she was underdeveloped-body weight 13.5 kg, height 99 cm.- and cyanotic. There was severe clubbing on fingers. There was grade II/VI ejection systolic murmur on left lateral border of the sternum. The preoperative examinations [EKG, echocardiogram, cardiac catheterization and biventriculogram] showed that complicated T.G.A. combined vena cava[S.D.D.]. Preoperatively, we decided the corrective surgery of Rastelli operation using a. pulmonary valved conduit. The operation was performed under total circulatory arrest using deep profound hypothermia combining with extracorporeal circulation. On operation, the anatomy of the heart showed that, 1. The subaortic conus was seen and subaortic muscles were hypertrophied. 2. The VSD[type II], behind the subaortic conus-about 1 cm. in diameter, was visible only through LV cavity and, 3. The pulmonary valve ring was hypoplastic and pulmonary valvular stenosis was seen also. The subpulmonic area [LV outflow tract] was obstructed with hypertrophied muscle and mitral valve. 4. Left superior vena cava was drained to RA via coronary sinus. 5. LAD coronary artery was originated from right coronary artery and ran anterior to the pulmonary artery. According to above anatomy, we performed the VSD closure with Teflon patch, and Mustard operation combined with LV-to-pulmonary artery bypass graft using the valve contained [Hancock 16 mm] conduit. Postoperatively, adequate blood pressure could be maintained under the state of using inotropic agent [epinephrine]. On the second postoperative day, the patient died of cardiac arrest due to low cardiac output syndrome, acute renal failure and pulmonary edema.

  • PDF

Blood Flow Changes by Anastomotic Method in Fontan Operation (폰탄 수술에서 문합방법에 따른 혈류 변화)

  • Kim, S.H.;Park, Y.H.;Cho, B.K.;Kim, J.H.;Hong, Y.S.;Kim, Y.H.;Kim, S.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.203-206
    • /
    • 1996
  • To understand the local fluid dynamics for different desists of Fontan operation, five models were made out of Pyrex glass to facilitate in-vitro study. Model I, II and III have same position of the center of the anastomosis of the IVC( inferior vena cava) with that of the SVC(superior vena cava), but Model IV and V have 10 mm offset between them. Also the anastomotic junction angles are different(Model I and $IV:90^{\circ}$, Model II and $V:70^{\circ}$, Model $III:45^{\circ}$). These models were then connected to a flow loop for flow visualization study. In Model I any dominant vortex was not seen in the central region of the juntion, but a large unstable vortex was created in the Model II and III. In Model IV and V a significant stagnation region was created in the middle of the offset region. It also showed that the flow direction from the IVC and SVC to the LPA(left pulmonary artery) and RPA(right pulmonary artery) highly depends on the offset of the junction rather than the anastomotic junction angle.

  • PDF

Open heart surgery on tetralogy of fallot (활로 4징증의 완전교정술에 대한 임상적 고찰)

  • 한병선
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.243-249
    • /
    • 1986
  • Thirty-two cases of tetralogy of Fallot corrected totally using extracorporeal circulation in this department are presented during the period from April 1983 to Feb. 1986. Types of right ventricular outflow tract obstruction were a case of pulmonic valvular stenosis, 3 cases of infundibular stenosis, and 28 cases of combined type. There were associated anomaly such as 3 cases of pulmonary arterial hypoplasia, 7 cases of atrial septal defect, a case of left superior vena cava, and 2 cases of right side aortic arch. Transannular patch for right ventricular outflow tract reconstruction was necessary in 12 cases. Operative death was 6 cases and late death was a case, but other remaining cases followed up over 2 months carried out normal life.

  • PDF