• 제목/요약/키워드: Velocity measurement

검색결과 2,151건 처리시간 0.037초

THE LUMINOSITY-LINEWIDTH RELATION AS A PROBE OF THE EVOLUTION OF FIELD GALAXIES

  • GUHATHAKURTA PURAGRA;ING KRISTINE;RIX HANS-WALTER;COLLESS MATTHEW;WILLIAMS TED
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.63-64
    • /
    • 1996
  • The nature of distant faint blue field galaxies remains a mystery, despite the fact that much attention has been devoted to this subject in the last decade. Galaxy counts, particularly those in the optical and near ultraviolet bandpasses, have been demonstrated to be well in excess of those expected in the 'no-evolution' scenario. This has usually been taken to imply that galaxies were brighter in the past, presumably due to a higher rate of star formation. More recently, redshift surveys of galaxies as faint as B$\~$24 have shown that the mean redshift of faint blue galaxies is lower than that predicted by standard evolutionary models (de-signed to fit the galaxy counts). The galaxy number count data and redshift data suggest that evolutionary effects are most prominent at the faint end of the galaxy luminosity function. While these data constrain the form of evolution of the overall luminosity function, they do not constrain evolution in individual galaxies. We are carrying out a series of observations as part of a long-term program aimed at a better understanding of the nature and amount of luminosity evolution in individual galaxies. Our study uses the luminosity-linewidth relation (Tully-Fisher relation) for disk galaxies as a tool to study luminosity evolution. Several studies of a related nature are being carried out by other groups. A specific experiment to test a 'no-evolution' hypothesis is presented here. We have used the AUTOFIB multifibre spectro-graph on the 4-metre Anglo-Australian Telescope (AAT) and the Rutgers Fabry-Perot imager on the Cerro Tolalo lnteramerican Observatory (CTIO) 4-metre tele-scope to measure the internal kinematics of a representative sample of faint blue field galaxies in the red-shift range z = 0.15-0.4. The emission line profiles of [OII] and [OIII] in a typical sample galaxy are significantly broader than the instrumental resolution (100-120 km $s^{-l}$), and it is possible to make a reliable de-termination of the linewidth. Detailed and realistic simulations based on the properties of nearby, low-luminosity spirals are used to convert the measured linewidth into an estimate of the characteristic rotation speed, making statistical corrections for the effects of inclination, non-uniform distribution of ionized gas, rotation curve shape, finite fibre aperture, etc.. The (corrected) mean characteristic rotation speed for our distant galaxy sample is compared to the mean rotation speed of local galaxies of comparable blue luminosity and colour. The typical galaxy in our distant sample has a B-band luminosity of about 0.25 L$\ast$ and a colour that corresponds to the Sb-Sd/Im range of Hub-ble types. Details of the AUTOFIB fibre spectroscopic study are described by Rix et al. (1996). Follow-up deep near infrared imaging with the 10-metre Keck tele-scope+ NIRC combination and high angular resolution imaging with the Hubble Space Telescope's WFPC2 are being used to determine the structural and orientation parameters of galaxies on an individual basis. This information is being combined with the spatially resolved CTIO Fabry-Perot data to study the internal kinematics of distant galaxies (Ing et al. 1996). The two main questions addressed by these (preliminary studies) are: 1. Do galaxies of a given luminosity and colour have the same characteristic rotation speed in the distant and local Universe? The distant galaxies in our AUTOFIB sample have a mean characteristic rotation speed of $\~$70 km $s^{-l}$ after correction for measurement bias (Fig. 1); this is inconsistent with the characteristic rotation speed of local galaxies of comparable photometric proper-ties (105 km $s^{-l}$) at the > $99\%$ significance level (Fig. 2). A straightforward explanation for this discrepancy is that faint blue galaxies were about 1-1.5 mag brighter (in the B band) at z $\~$ 0.25 than their present-day counterparts. 2. What is the nature of the internal kinematics of faint field galaxies? The linewidths of these faint galaxies appear to be dominated by the global disk rotation. The larger galaxies in our sample are about 2"-.5" in diameter so one can get direct insight into the nature of their internal velocity field from the $\~$ I" seeing CTIO Fabry-Perot data. A montage of Fabry-Perot data is shown in Fig. 3. The linewidths are too large (by. $5\sigma$) to be caused by turbulence in giant HII regions.

  • PDF

껌씹기가 저작근의 경도와 탄성도에 미치는 효과 (Muscle Stiffness and Elasticity of Masticatory Muscles on Gum Chewing)

  • 원태희;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제32권4호
    • /
    • pp.421-429
    • /
    • 2007
  • 최근 tactile sensor 를 사용하여 근육의 경도와 탄성도를 조사하는 방법이 저작근의 새로운 평가방법으로 제시되고 있다. 본 연구의 목적은 촉각센서를 이용하여 일정시간 껌씹기를 시행전, 중, 후의 저작근의 경도와 탄성도를 조사하여 향후 턱관절 장애 환자의 저작근 평가를 위한 기초자료를 확보하는 데 있다. 건강한 성인 8명을 대상으로 양측 전측두근(anterior temporalis), 하교근(inferior masseter)의 경도와 탄성도를 촉각센서 (Venustron II, Axion Co., Japan)를 이용하여 다음과 같이 측정하였다. 피검자들을 unit-chair에 바로 앉힌 상태에서 양측 교근 및 측두근 부위를 촉진을 통해 전 측두근(temporalis anterior), 하 교근(masseter inferior) 두 부위를 펜으로 표시하였다. 실험의 재현성을 위하여 투명한 종이에 ala-tragus line을 표시한 후 두 부위를 투명종이 위에 표시하였다. 편안한 상태에서 촉각센서를 사용하여 양측 하 교근 및 전 측두근의 경도와 탄성도를 측정한 후, 껌(Excellent Breath, Taiyo Co., Japan)을 양측으로 씹게 하여 1초당 2회의 속도로 씹게 하였다. 껌을 40분동안 저작하는 동안 10분, 20분, 30분, 40분에 양측 하 교근 및 전 측두근의 경도와 탄성도를 측정하였다. 그 후 껌을 뱉게 하고 하악의 안정위 상태에서 10분, 20분, 30분, 40분 후 양측하 교근 및 전 측두근의 경도와 탄성도를 각각 측정하였다. 측정치들을 반복측정 이원분산분석과 다중비교를 통하여 비교하였다. 실험결과 측두근과 교근을 비교 시 탄성도, 경도 모두 교근의 변화가 유의하게 크다. 또한 저작하면 서서히 경도는 증가하며 탄성도는 반대로 감소한다. 탄성도 및 경도는 저작 시 신속히 증가하나 저작 종료 후에는 탄성도만 신속히 회복되나 경도는 약 10분 이상의 일정시간이 지나야 회복된다. 이상의 결과들을 보아 임상적으로 좀 더 다양한 연구와 기초자료가 확보된다면, 저작근의 근육 상태를 평가하는데, 근육의 탄성도와 경도를 조사하는 tactile sensor system은 유익한 기기로서 활용될 수 있을 것이다.

후정해변 고파랑 조건하에서 파랑유속 방향전환점에서 발생하는 난류성분의 측정 (Measurement of Turbulence Properties at the Time of Flow Reversal Under High Wave Conditions in Hujeong Beach)

  • 장연식;도종대;김선신;안경모;진재율
    • 한국해안·해양공학회논문집
    • /
    • 제29권4호
    • /
    • pp.206-216
    • /
    • 2017
  • 교란운동에너지(TKE)와 레이놀즈 응력의 수직성분($-{\bar{u^{\prime}w^{\prime}}}$)에 대한 한 주기 파장 안에서의 시간변화를 관측자료를 사용하여 분석하였다. 관측자료는 동해에서 온대성저기압이 발달하였던 2017년 1월 14일부터 18일까지 동해안 후정해변에서 측정한 파랑자료를 사용하였다. 이 기간 동안 관측된 모든 파랑자료들 중에서 비슷한 형태를 갖는 수백 개의 규칙파들을 구분하였으며 이 자료를 토대로 Ensemble Average 기법을 사용하여 이 기간 파랑특성을 대표하는 세 개의 평균파를 계산하였다. 그리고 이 평균파를 기준으로 각 파의 요동을 측정하여 한 주기 동안의 교란운동에너지와 레이놀즈 응력을 계산하였다. 이렇게 계산된 자료들을 분석한 결과 교란운동에너지는 파랑의 평균유속과 비슷한 분포를 나타내었으나(즉 유속이 최대값을 나타낼 때 교란운동에너지도 최대값을 나타내었다), $-{\bar{u^{\prime}w^{\prime}}}$는 파랑의 수평유속 방향이 전환되는 '방향전환점'에서 가파르게 증가하는 경향을 나타내었다. 이러한 $-{\bar{u^{\prime}w^{\prime}}}$의 독특한 분포는 Nielsen(1992)에 의해 제안된 난류 convection 현상을 뒷받침하는 발견으로 퇴적물과 같은 물질들의 부유현상이 파랑의 '방향전환점(한 주기 안에서 파랑의 횡단방향 유속 부호가 바뀌는 시점)'에서 촉진될 수 있음을 보여준다. 이렇게 관측된 난류에너지 분포 특성을 CADMAS-SURF 모델을 사용하여 구현해 보았다. 그 결과 교란운동에너지의 경우 모델결과와 관측치 사이에 유사성이 발견되었으나 레이놀즈 응력($-{\bar{u^{\prime}w^{\prime}}}$)의 경우 모델이 '방향전환점'에서의 증가현상을 구현해 내지 못하였다. 이는 CADMAS-SURF와 같은 Reynolds-Averaged Navier-Stokes(RANS) 모델들이 가지는 한계점으로 RANS 모델의 경우 레이놀즈 응력과 같은 난류에너지가 평균유속의 분포에 강한 영향을 받기 때문인 것으로 판명되었다.

2002년 여름철 경사진 광릉 낙엽 활엽수림에서의 이산화탄소 교환 (CO2 Exchange in Kwangneung Broadleaf Deciduous Forest in a Hilly Terrain in the Summer of 2002)

  • 최태진;김준;임종환
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.70-80
    • /
    • 2003
  • 본 연구에서는 KoFlux네트워크 타워 관측소의 하나인 광릉 낙엽 활엽수림에서 최초로 직접 관측된 이산화탄소 플럭스를 보고한다. 2002년 6월부터 8월까지 에디 공분산 시스템을 다른 기상 관측 기기들과 함께 30 m 타워에 설치하였다. 관측 장소가 계곡과 같은 경사지에 위치해 있음에도 불구하고 관측된 난류 특성이, 제한된 풍향(즉, 90$\pm$45$^{\circ}$)의 경우, 평평하고 균질한 이상적인 장소에서 관측된 것들과 크게 다르지 않았다. 관측 자료 회수율은 비록 낮았으나, 분석된 예비 결과는 고무적이고, 연구해야 할 가치가 있는 것으로 나타났다. 이류 항을 무시하면, 생태계의 순 $CO_2$ 교환(NEE)은 6월에서 8월까지 약 -1.2에서 0.7 mg m$^{-2}$ s$^{-1}$의 범위를 보였다. 약한 난류가 야간 NEE에 미치는 효과를 마찰 속도(u*)및 저류 항의 산출과 관련하여 살펴보았다. 낮은 u*가 NEE에 미치는 영향은 약 0.2 m s$^{-1}$의 문턱 값을 기점으로 뚜렷하게 나타났다. 야간 NEE에 미치는 저류 항의 역할은 거의 나타나지 않았는데, 이는 밤 동안 산림 내에 축적된 $CO_2$가 경사면을 따라 배수류로 빠져나갔기 때문인 것으로 사료된다. 이는 또한 저류 항을 한 높이에서만 관측된 농도 자료를 사용함으로 생긴 오차로 인한 인위적인 결과일 수도 있다. 쌍곡선 광 반응식을 적용한 결과, 관측된 NEE 변화의 80% 이상이 설명되어, 이 산림 지역의 $CO_2$ 교환이 주로 빛에 의해 조절됨을 보여주었다. 이러한 관계식은 계절에 걸쳐 빠진 자료를 채워 넣는 자료 처리 과정에 효과적으로 사용될 수 있다. 마지막으로, 선형류 모형에 근거한 간단한 규모 분석에 의하면, 이류항의 효과가 NEE산출에 큰 영향을 미칠 수 있는 것으로 나타났다.

폭 함수를 기반으로 한 Clark 모형의 매개변수 추정 (Parameters Estimation of Clark Model based on Width Function)

  • 박상현;김주철;정관수
    • 한국수자원학회논문집
    • /
    • 제46권6호
    • /
    • pp.597-611
    • /
    • 2013
  • 본 연구에서는 Clark 모형의 시간-면적곡선의 구성 방법과 적용성을 검토하고 모멘트 원리에 의한 도달시간, 저류상수를 합리적으로 산정하기 위한 방법론을 고찰해 보았다. 격자 기반으로 폭 함수를 구성하고 운동과정을 순수 이류현상으로 가정하여 시간-면적곡선으로 사용하였다. 또한 도달시간과 저류상수는 모멘트 법의 원리에 따라 Clark 모형 구조에 적용하여 해석적으로 산정할 수 있는 방법을 제시하였다. 적용성 검토를 위해 (1) HEC-1에서 기본적으로 제공하는 좌우 대칭형상인 무차원 시간-면적곡선을 적용하고 매개변수 산정은 관측유출수문곡선과 계산된 유출수문곡선의 오차를 최소화하는 HEC-1의 최적화 기법 사용, (2) HEC-1에 폭 함수 기반의 시간-면적곡선을 적용하고 매개변수 산정은 HEC-1의 최적화 기법 사용, (3) 폭 함수 기반의 시간-면적곡선을 이용하여 모멘트 원리에 따라 매개변수를 직접 산정하는 방법을 적용하였다. 방법별로 산정된 Clark 모형의 매개변수들을 HEC-1을 이용하여 직접유출량을 산정하고 관측 직접유출량과 비교하여 얻은 결과는 다음과 같다. (1) 정량적으로 비교하기 위해 산정한 첨두유량과 첨두발생 시간의 상대오차 및 효율계수 E(Efficiency Coefficient)를 비교한 결과, 시간-면적곡선을 폭 함수로 대체하여 HEC-1으로부터 추정된 매개변수가 관측값을 잘 반영하였다. (2) Clark 모형의 올바른 적용을 위해서는 HEC-1에서 기본적으로 제공하는 좌우 대칭형상인 무차원 시간-면적곡선보다는 적용 대상유역의 배수구조가 적절하게 반영된 시간-면적곡선의 사용이 합리적일 것으로 판단된다. (3) 본 연구 방법은 첨두유량과 첨두시간의 상대오차 범위와 재현정도를 나타내는 효율계수를 비교하여 볼 때 대체로 양호하게 모의되었고, 대상유역별 유량측정성과인 하천평균유속과 비교했을 때 본 연구 방법이 다소 실제 유속에 접근하고 있음을 확인하였다. (4) 본 연구에서 모멘트 원리를 기반으로 제안한 매개변수 추정을 위한 방법은 유역의 이류현상과 저류현상을 정량적으로 계량할 수 있는 효율적인 관계식으로 사용할 수 있음을 확인하였다. (5) 본 방법에 의해 계산된 수문곡선이 대부분 관측수문곡선의 우측으로 왜곡되고 첨두유량은 과소평가 되는 것을 보이고 있다. 이것은 평균과 분산만을 고려하여 유역을 하나의 평균이송속도로 모의한 본 연구의 한계점으로 판단된다. 만약 모멘트의 왜곡도를 고려하고 유역을 지표면과 하천으로 나누어 평균이송속도를 모의한다면 물리적인 특성을 충분히 반영하여 매개변수를 추정 할 수 있을 것으로 판단된다.

고려인삼(高麗人蔘)의 노화억제작용(老化抑制作用)에 관한 연구(硏究) 제1보(第1報) 홍삼(紅蔘)과 백삼(白蔘)의 노화억제작용(老化抑制作用) 비교연구(比較硏究) (Studies on the Anti-aging Action of Korean Ginseng (I) Comparative Study of Red and White Ginsengs on Anti-aging Action)

  • 최진호;오성기
    • 한국식품영양과학회지
    • /
    • 제12권4호
    • /
    • pp.323-335
    • /
    • 1983
  • 홍삼(紅蔘)과 백삼(白蔘) 항산화작용(抗酸化作用)에 의한 노화억제작용(老化抑制作用)을 구명(究明)하기 위하여 80% ethanol extract 및 수포화(水飽和)부탄올로 이행(移行)한 saponin을 시료(試料)로 하여 in vitro 및 in vivo 실험(實驗)을 통하여 홍삼(紅蔘)과 백삼(白蔘)의 노화억제작용(老化抑制作用)을 비교(比較)하였다. DPPH에 대한 전자공여능(電子供與能)(EDA), TBA value 및 peroxide value에 의한 과산화지질생성억제작용(過酸化脂質生成抑制作用), superoxide dismutase 및 peroxidase의 활성측정(活性測定)등으로 홍삼(紅蔘)과 백삼(白蔘)의 노화억제작용(老化抑制作用)을 비교(比較)한 결과(結果), 홍삼(紅蔘)은 장기간(長期間)에 걸친 연속투여(連續投與)에서 백삼(白蔘)보다 과산화지질생성억제작용(過酸化脂質生成抑制作用). superoxide dismutase 및 peroxidase의 활성(活性)을 유의성(有意性)있게 증가(增加)하였다. 생체내실험(生體內實驗)에서 홍삼(紅蔘)이 백삼(白蔘)보다 노화억제작용(老化抑制作用)이 현저한 것은 증삼(蒸參) 및 가공처리중(加工處理中) saponin pattern의 변화(變化)에 기인(起因)하며 백삼(白蔘)의 PT/PD ratio가 0.401인데 반(反)해 홍삼(紅蔘)의 PT/PD ratio가 0.561로서 triol saponin이 증가(增加)되었기 때문이다.

  • PDF

수중글라이더를 활용한 동해 아중규모 중층성 소용돌이 발견 (First Observational Finding of Submesoscale Intrathermocline Eddy in the East Sea using Underwater Glider)

  • 박종진
    • 한국해양학회지:바다
    • /
    • 제24권2호
    • /
    • pp.332-350
    • /
    • 2019
  • 2017년 8월 7일부터 25일까지 수중글라이더를 활용하여 $37.9^{\circ}N$ 위도 라인를 따라 동경 $129.0^{\circ}E{\sim}131.3^{\circ}E$ 사이를 왕복하는 단면 관측을 수행하였다. 해당 경로는 국립수산과학원 정기선박 관측라인 중 106 라인을 따른 것으로 이 경로를 따라 약 18일간 운용하였으며 위치 유지 모드로 동작했던 시간을 제외하고 총 440 km를 비행하였고, 그동안 고해상도 수온 및 염분의 공간 단면을 관측하였다. 본 관측 해역은 약 0.8 m/s의 강한 유속을 갖는 동한난류가 북상하고 있는 상황이었음에도 불구하고, 해당 수중글라이더는 지정된 경로에서부터 RMS 거리 400 m 이내를 벗어나지 않고 정확하게 106 라인을 따라 비행하였다. 본 관측에서 얻어진 고해상도 물성 단면 구조를 국립수산과학원 정선 관측 자료와 비교함으로써 해양환경에 지대한 영향을 끼치는 전선역이나 소용돌이와 같은 현상을 관측하기 위해서 고해상도 관측이 얼마나 중요한지 확인할 수 있었다. 이러한 수중글라이더 관측을 통해 이제까지 발견하지 못했던 새로운 소용돌이를 발견할 수 있었다. 이 소용돌이는 수평폭이 10~13 km, 수직폭은 200 m 가량되는 렌즈 형태를 가지고 있으며 시계방향으로 회전하는 아중규모 중층성 소용돌이(submesoscale intrathermocline eddy)다. 수온약층 내 혹은 직하부에 존재하면서 아중규모의 렌즈형태의 구조를 갖는 이러한 중층성 소용돌이는 동해에서 처음 발견되었기 때문에 Korea intrathermocline eddy(Keddy)로 명명하였다. 이 Keddy는 다음과 같은 전형적인 중층성 소용돌이(intrathermocline eddy)의 특징을 가지고 있다. Keddy는 수온약층 하부인 수심 약 170 m, 즉 중층에서 유속최대값을 갖는 특징이 있고, 따라서 해표면에는 해당 지오포텐셜 구조가 드러나지 않는 2차 순압성 구조를 가지고 있다. 또한 중앙부의 성층화가 주변보다 약하고, 수평크기가 1차 순압성 로스비 변형반경과 유사하며, 로스비 수가 0.7로 1에 근접한다.

호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study (Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy)

  • 박제완;김민수;엄기천;최성훈;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.25-33
    • /
    • 2021
  • 목 적 : 본 연구를 통해 호흡동조방사선치료(Respiratory Gated Radiation Therapy, RGRT)시 환자 호흡 속도에 따른 Trigger mode의 정확성과 유용성을 평가하고자 한다. 대상 및 방법 : 호흡 속도에 따른 Trigger mode의 정확성을 평가하기 위해 QUASARTM 호흡 움직임 팬텀에 3 mm의 기준 표지자(Fiducial marker, gold marker)를 삽입하여 본원 한달 동안 환자의 평균 호흡인 20 bpm(Breath per minute)을 기준으로 4DCT 촬영 후 정중앙(Median)에 위치한 표지자에 윤곽 묘사(Contouring)를 하였다. OBI(On Board Imager)가 장착된 Truebeam STxTM를 이용해 방사선조사 구간인 Gating window를 Lower threshold는 2.0 mm로 모든 측정 조건에서 고정시키고, Upper threshold를 최고 위상으로부터 각각 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, 3.0 mm로 바꿔가며 측정하였다. 위와 같은 조건에서 평균 호흡 속도인 20 bpm을 기준으로 10 bpm, 30 bpm, 40 bpm, 50 bpm, 60 bpm 호흡속도를 바꿔가며 방사선이 끊기는 순간인 'Once at beam off'로 5회 촬영하였다. 같은 방법으로 3일간 반복 촬영 후 각 속도 별 오차율을 비교하였다. 결 과 : 기준 호흡 속도 20 bpm에서 최고 위상으로부터 각각 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, 3.0 mm Upper threshold에서 Trigger mode의 beam off시 차이는 3일간의 평균값으로 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, 1.66±0.06 mm이다. 기준 호흡 속도(20 bpm)대비 호흡 속도 변화에 따른 측정 결과는 최대 절대차이(Absolute Difference)의 경우 1일차, 2일차, 3일차 모두 3 mm Upper threshold에서 평균 0.81±0.08 mm로 차이가 확인되었다. 호흡 속도와 절대차이의 편차(Variation)에 대한 상관관계를 평가하기 위한 결정계수 R2는 3일 평균 수치로 각각 0.838, 0.887, 0.770, 0.850, 0.906로 확인되었다. 3일간의 Threshold 모든 변수에서 p-value는 설정 유의수준 0.05 이하로 차이유의를 확인하였다. 결 론 : 호흡동조방사선치료 시 Trigger mode를 이용하여 영상유도를 할 경우 기준 호흡 속도(20 bpm)에서의 Trigger mode의 오차율이 평균 ±0.04 mm 값으로 정확성과 유용성을 확인 할 수 있었다. 그러나 호흡 속도에 따른 부정확성(Uncertainty) 또한 발생할 수 있다는 것을 알 수 있었으며, 특히, 기준 호흡 속도 대비 느려지는 경우(< 20 bpm)보다 빨라지는 경우(> 20 bpm) 영상획득에 대한 부정확성은 커졌다. 따라서 사전 모의치료시의 호흡을 선별하고 호흡을 유지하기 위한 호흡교육과 치료 중 적극적인 실시간 모니터링(Monitoring)이 필요하다고 사료된다.

금강하구 연안역에서 HF radar로 측정한 유속의 정확도 (Accuracy of HF radar-derived surface current data in the coastal waters off the Keum River estuary)

  • 이상호;문홍배;백혜연;김창수;손영태;권효근;최병주
    • 한국해양학회지:바다
    • /
    • 제13권1호
    • /
    • pp.42-55
    • /
    • 2008
  • 금강하구 연안역에서 HF radar로 측정한 유속의 정확도를 평가하기 위해 HF radar의 마주보는 radial 유속들을 비교하고, HF radar로 측정한 유속을 현장측정 유속과 비교하였다. 비교 자료들에 대한 회귀선과 편차는 주성분 분석(Principal Component Analysis)으로 구하였다. HF radar site를 연결하는 선의 중간지점에서 마주보는 radial vector를 비교하였을 때 RMS 편차는 동계에 4.4 cm/s, 하계에 5.4 cm/s이었다. HF radar와 유속계로 측정한 유속성분을 비교하여 분석된 RMS 편차에서 GDOP(Geometric Dilution of Precision) 효과를 제거하였을 때 HF radar의 합성 속도 측정오차는 GDOP 값이 적절한 정점들에서 5.1 cm/s 이내였다. 서로 다른 두 방법에 의해 구해진 이 결과는 연구해역에서 HF radar로 측정된 유속의 정확도 하한이 5.4 cm/s임을 제시한다. 기존의 연구에서와 같이 RMS 편차는 섬 주변에 있는 관측점에서 크게 되고, 두 radar에서 평균거리가 멀어질수록 신호 대 잡음수준과 radial vector 교차각의 감소로 인해 증가하였다. GDOP 값을 이용한 오차분리 과정에서 속도성분별 GDOP 값이 유사하고 비교 유속의 성분별 RMS 편차도 비슷한 값을 보이는 경우 HF radar 유속의 오차가 불확실한 값으로 도출될 수도 있음이 밝혀졌다. GDOP가 정상적인 radar 관측 범위 내에 있는 정점에서 측정된 유속을 조류와 해류로 분리하였을 때 HF radar 유속에서 구해진 조류타원의 특성은 유속계로 측정된 타원특성과 잘 부합하였고, 해류의 시간적 변화는 바람과 밀도장의 외력에 의한 물리적 과정을 반영하는 반응을 보였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF