• Title/Summary/Keyword: Velcro belt

Search Result 6, Processing Time 0.025 seconds

Study on the Development of SCBA Belt for Firefighters (소방용 등지게 벨트의 제품개발에 관한 연구)

  • Kang, Minyoung;An, Seungkook;Lee, Sunhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.3
    • /
    • pp.537-547
    • /
    • 2017
  • This study evaluates the wearing performance of a self-contained breathing apparatus (SCBA) belt for firefighters in Korea. A SCBA belt design was suggested based on the wearing evaluation of a SCBA belt; subsequently, prototypes I and II were created. A wearing evaluation of prototypes with improved design and design preference was performed. Six designs elements of the SCBA belt for firefighters were suggested based on the survey results of wearing the SCBA belt and for the SCBA belt design preference for use by firefighters. First, belt material should be made of black high-strength aramid textiles. In addition, Velcro should be used to attach and detach retroreflective and fluorescent materials along with various colors for visibility. Second, the chest belt should be made of the same material used for other parts; in addition, the chest belt should be moved to the center for center of gravity and a cobra buckle should be applied. Third, an O-ring should be applied to the back and the belt connected to the O-ring should distribute the weight in six axes. Fourth, a detachable air respirator should be able to separate by using upper and lower cobra buckles. Fifth, a separable leg belt and a detachable pocket are also suggested. Sixth, a ring for walkie-talkies, alarms and equipment as a fabric ring are also suggested. Prototype III with an improved design was created based on the results of the design suggestion.

A Study for Development of Smart Taekwondo Uniform with Enhanced Functionality for Children (기능성이 향상된 아동용 스마트 태권도복 개발을 위한 연구)

  • Kim, Kyung-A
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.2
    • /
    • pp.169-181
    • /
    • 2009
  • The purpose of this study was to provide basic information for developing a smart taekwondo uniform with enhanced functionality for children by investigating the wearing condition and satisfaction of taekwondo uniform among taekwondo training children. The data were collected from 162 children living in Seoul and Daegu. For data analysis were performed descriptive statistics, ${\chi}2$ -test and t-test using SPSS Ver. 12. The results of the analysis are as follows. The results revealed that respondents wearing the general training uniform during their training period were the most. The dissatisfaction for the general training uniform was a high price, lack of symbolic, lack of functionality in textiles, lack of variety in design and unfittness of size in order. The developed uniform can adjust the length using a zipper type fastener, and can be used in all seasons as the lining is detachable. It also uses nano-silver material, and soil release finish. It enhances the functionality of movement by treating with raglan sleeve and sleeve hem velcro tape, and designs the upper garment in the draping. Safety is improved through attaching GPS, and elastic material is mixed in the neckline for putting on and off easily. Piece of cloth is added inside the closing of the upper garment. Rings are made for fixing the taekwondo uniform belt. Pocket is designed in the lower garment and colors are multiplied.

  • PDF

Development of Children's X-ray Imaging Assist Device (어린이 방사선검사 보조기구의 개발)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Ko, Cheol-Woo;Kim, Jong-Ki
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.243-249
    • /
    • 2020
  • Examination with medical radiography is the most significant advances in medicine in the 21st century. Diagnostic imaging occupies an important position in all medical subjects, surgical and internal medicine, including radiology, orthopedics, and neurosurgery. However, the invention associated with conventional radiography devices has focused only on emphasizing the efficient aspects of the examination or obtaining clearer images without considering the age and disease-induced constraints of the patient's posture. The newly developed X-ray aids to solve this problem can effectively perform X-ray imaging of children's who have difficulty communicating and controlling. It is also thought to be a good way to provide accurate imaging information and minimize radiation exposure for children.

Development of Abdominal Compression Belt and Evaluation of the Efficiency for the Reduction of Respiratory Motion in SBRT (체부 정위방사선치료 시 호흡운동 감소를 위한 복부 압박기구 개발 및 유용성 평가)

  • Hwang, Seon-Bung;Kim, Il-Hwan;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Jeong, Seong-Min;Kim, Gi-Hwan;Lee, Ah-Ram;Cho, Yu-Ra
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • Purpose: It's essential to minimize the tumor motion and identify the exact location of the lesions to achieve the improvement in radiation therapy efficiency during SBRT. In this study, we made the established compression belt to reduce respiratory motion and evaluated the usefulness of clinical application in SBRT. Materials and Methods: We analyzed the merits and demerits of the established compression belt to reduce the respiratory motion and improved the reproducibility and precision in use. To evaluate the usefulness of improved compression belt for respiratory motion reduction in SBRT, firstly, we reviewed the spiral CT images acquired in inspiration and expiration states of 8 lung cancer cases, respectively, and analyzed the three dimensional tumor motion related to respiration. To evaluate isodose distribution, secondly, we also made the special phantom using EBT2 film (Gafchronic, ISP, USA) and we prepared the robot (Cartesian Robot-2 Axis, FARARCM4H, Samsung Mechatronics, Korea) to reproduce three dimensional tumor motion. And analysis was made for isodose curves and two dimensional isodose profiles with reproducibility of respiratory motion on the basis of CT images. Results: A respiratory motion reduction compression belt (Velcro type) that has convenient use and good reproducibility was developed. The moving differences of three dimensional tumor motion of lung cancer cases analyzed by CT images were mean 3.2 mm, 4.3 mm and 13 mm each in LR, AP and CC directions. The result of characteristic change in dose distribution using the phantom and rectangular coordinates robot showed that the distortion of isodose has great differences, mean length was 4.2 mm; the differences were 8.0% and 16.8% each for cranio-caudal and 8.1% and 10.9% each for left-right directions in underdose below the prescribed dose. Conclusion: In this study, we could develop the convenient and efficient compression belt that can make the organs' motion minimize. With this compression belt, we confirmed that underdose due to respiration can be coped with when CTV-PTV margins of mean 6 mm would be used. And we conclude that the respiratory motion reduction compression belt we developed can be used for clinical effective aids along with the gating system.

  • PDF

A Study on the Phased Cultural Product Design with Characteristics of Unlined Cheollik in Early 17th Century and Baby Typed Doll's Body (17세기 초 홑철릭 유물의 시대특성과 유아형 인형의 체형특성을 응용한 단계별 복식문화상품 디자인 연구)

  • Choi, Jeong
    • Fashion & Textile Research Journal
    • /
    • v.19 no.4
    • /
    • pp.385-399
    • /
    • 2017
  • This study will broaden the application of doll costume product with historical characteristics and the image of unlined cheollik in the $17^{th}$ century period of transition during the Joseon Dynasty. Historical design sources were extracted from old documents and precedent studies. Unlined cheollik of Shin Gyeong-yu, meritorious retainer, were selected as main reference-relic because of various fabric, preserved conditions and definite shape. 'Baby doll' was selected as main model because of consumer preferences and awareness. Design sources from unlined cheollik in the early $17^{th}$ century were about a 1:2 ratio of upper and under parts, removable separated doori-somae, knife-shaped collar (outside), projected square collar (inside), long pleats line, side slit, traditional flat fell seam sewing. Trapezoidal side line, round waistline, and thin fabric were applied in designs because of toddler-body of doll model. Three designs were produced in step 1: Cheollik A focusing on the historical remake (traditional type), Cheollik B with belt and side slit (crossover type), and Cheollik C with back- opening (modern type). In step 2, interview with fashion major student was conducted to increase the utility of designs. As a result, modern trend sources (frill, velcro, round armhole line, slope of sleeves, and floral pattern) were reflected in Cheollik B, C. Finally, three doll cheollik and cheollik-styled doll apron sample were produced. Various versions must be suggested in the study of doll costume products with traditional sources that balance historical characteristics and practicality to improve customer satisfaction.

A Study on the Actual Wearing Conditions of Battle Dress Uniform for the Korean Police Special Weapons Attack Team (경찰특공대(SWAT) 작전복(BDU) 착용실태에 관한 연구)

  • Moon Yeon-Sil;Choi Hei-Sun;Kim Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.5 s.95
    • /
    • pp.108-119
    • /
    • 2005
  • The objective of the study is was investigate the condition of the battle dress uniform worn by male members of the Korean Police Special Weapons Attack Team(KP-SWAT), identify problems, and provide basic raw materials for developing improved design of BDU. For this purpose, the researcher conducted a questionnaire survey on 92 male members of SWAT (Special Weapon Attack Team) units in Seoul using a questionnaire developed through observation and interview. Also, the body sizes of male SWAT members were measured. According to the results of body size measurements, male SWAT members generally require uniforms with a target bust girth, armhole, biceps circumference, thigh and calf circumference, longer jacket length, sleeve length, and trouser length to the knee. According to the results of the questionnaire survey, they reported dissatisfaction with the fit. In addition, they said that the Pockets are positioned too low for convenient use. Many subjects reported that their trousers were too short because of the rubber rings at the bottom of the legs. In addition, many subjects requested the alteration of the inconveniences caused by the designs finished with velcro on the bottom collar of the upper uniform, the marks and ensigns of the upper uniform, the bottom of the upper and lower uniform, and several pockets. Furthermore, there were many complaints concerning how they had to wear their uniform. The most frequently worn out and the body parts most often injured in field training and operations, they were reported, on the upper uniform, as the elbow, collar, neck, armpit, shoulder, and sleeve hem in that order, and on the lower uniform, the knee, interior calf, waist (belt rings), buttocks (rear pockets), and the bottom of the trousers (ankle) in that order As for questions concerning priorities in the improvements of the operational uniform and preferred design, the subjects recommended improvement in safety (protectiveness), workability (motional flexibility), design (shape), fit (size), comfort, ease in terms of putting on and taking off, etc., and the majority preferred two-piece designs ($67.4\%$), followed by one-piece ($30.4\%$), or both ($2.2\%$).