• Title/Summary/Keyword: Vehicle Load

Search Result 1,442, Processing Time 0.027 seconds

Analysis of Nonpoint Sources Runoff Characteristic by Road Types (도로 유형별 비점오염원 유출특성 분석)

  • Yoon, Young-Sam;Kwon, Hun-Gak;Yi, Youn-Jung;Yu, Jay-Jung;Lee, Chun-Sik;Lee, Jae-Kwan
    • Journal of Environmental Science International
    • /
    • v.19 no.11
    • /
    • pp.1375-1384
    • /
    • 2010
  • Growth in population and urbanization has progressively increased the loading of pollutants from nonpoint sources as well as point sources. Especially in case of road regions such as city trunk road, national road and highway are rainfall and pollutants runoff intensive landuses since they are impervious and emit a lot of pollutants from vehicle activity. This research was conducted to investigate the nonpoint sources concentration and quantifying stormwater pollutants which are contained in rainfall runoff water. Three different monitoring sites in Jinju and Changwon city were equipped with an automatic rainfall gauge and flow meter for measuring rainfall and the volume of rainfall runoff. In the case of average EMC value, city trunk road was shown the highest value in target water quality items like as BOD, COD, SS, TN and TP. Or the amount of runoff loads by water quality items showed the highest value in city trunk road. And runoff load in city trunk road was 43.8 times high value compared to highway by value of city trunk road $356.7 mg/m^2$, highway $8.150 mg/m^2$, national road $19.99 mg/m^2$ in the case of BOD.

Dynamic performance of girder bridges with explosion-proof and aseismic system

  • Wang, Jingyu;Yuan, Wancheng;Wu, Xun;Wei, Kai
    • Structural Engineering and Mechanics
    • /
    • v.61 no.3
    • /
    • pp.419-426
    • /
    • 2017
  • Recently, the transportation of dangerous explosive goods is increasing, which makes vehicle blasting accidents a potential threat for the safety of bridge structures. In addition, blasting accidents happen more easily when earthquake occurs. Excessive dynamic response of bridges under extreme loads may cause local member damage, serviceability issues, or even failure of the whole structure. In this paper, a new explosion-proof and aseismic system is proposed including cable support damping bearing and steel-fiber reinforced concrete based on the existing researches. Then, considering one 40m-span simply supported concrete T-bridge as the prototype, through scale model test and numerical simulation, the dynamic response of the bridge under three conditions including only earthquake, only blast load and the combination of the two extreme loads is obtained and the applicability of this explosion-proof and aseismic system is explored. Results of the study show that this explosion-proof and aseismic system has good adaptability to seism and blast load at different level. The reducing vibration isolation efficiency of cable support damping bearing is pretty high. Increasing cables does not affect the good shock-absorption performance of the original bearing. The new system is good at shock absorption and displacement limitation. It works well in reducing the vertical dynamic response of beam body, and could limit the relative displacement between main girder and capping beam in different orientation so as to solve the problem of beam falling. The study also shows that the enhancement of steel fibers in concrete could significantly improve the blast resistance of main beam. Results of this paper can be used in the process of antiknock design, and provide strong theoretical basis for comprehensive protection and support of girder bridges.

Research about VVVF direct subways Secondary source unit(SIV)180KVA for using Filter Capacitor(FC) maintenance & limit of use (VVVF 직류전동차의 보조전원장치(SIV)180KVA용에 사용되는 필터콘덴서(FC) 유지보수 및 사용한도에 관한 연구)

  • Shin, Hye-Jin;Woo, Suk-Tae;Shin, Min-Ho;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1345-1351
    • /
    • 2010
  • First, In this essay we research about secondary source unit(SIV)180KVA is install on VVVF direct subways for using Filter Capacitor(FC) maintenance & limit of use. Vehicle's extendly use and congestly at load for Catenary voltage and load change about output change and in SIV unit there are important device named GTO Thyristor, Power Transistor Module device become short and it often happen. We analysis the fault cause and there are effects and we know the secondary source unit in filter capacitor FC1~4 input harmonic distortion component's filtering don't do correctly so we study the capacitor extend use for the component change and the outside condition by slow property changed happen and we check before and when its fault, its difficult to measure. Finally, In this research we care for this reason and we study about capacitor maintenance through control and measure ways improvement and capacitor's life spans limit of use.

  • PDF

A SRM driving with voltage and switching angle for maximum torque/efficiency and minimum torque ripple (최대 토크/효율 및 최소 토크맥동을 위한 스위칭각/전압에 의한 SRM 운전)

  • 차현록;김현덕;김광현;임영철;장도현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.309-317
    • /
    • 2000
  • This paper presents the switching angle and voltage to maximize torque/efficiency and minimize torque ripple in the 4-phase 6-poles Switched Reluctance Motor(SRM). SRM drive has high saturation and nonlinear characteristics of inductance. So we cannot hard to find optimal condition by using analytic method. Therefore it is hard to find the operating the switching angle and voltage through the approximated analysis and computer simulation by using SIMULINK according to the speed and torque required by load. From the results, we can say that the optimum average voltage is determined by the load only and the speed is determined by the optimum turn-on/off angle only. And the maximum efficiency and minimum torque ripple depend on switching angle, not on voltage. And then one-chip microcontroller controls the switching angle and voltage of an asymmetrical inverter in the SRM driver. This drive method, which is expect that the driving methods, which are maximizing torque/efficiency and minimizing torque ripple, will be suitable for the electric vehicle, the industrial application and household appliances.

  • PDF

Influence of Load on Welding Stress Distribution of Structural Steel (구조용 강재의 용접응력 분포에 미치는 작용력의 영향)

  • Lee, Sang Hyong;Chang, Kyong Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.555-564
    • /
    • 2004
  • Steel materials, which are normally used in bridge structures, are prone to corrosion and have thin plate structures. Steel bridges that have been damaged through increased vehicle load and corrosion are frequently expected to be strengthened. Repair or strengthening methods generally include cutting, bolting, and welding. The basic characteristics of stress and deformation behavior generated by cutting and welding in the course of the repair work, however, are not yet understood. It is difficult to say whether the safety of the structure after welding conforms with existing safety evaluation methods.Therefore, to gain confidence in the material and to guarantee the safety of the structure after welding, the stress generated by heat, through welding and cutting, was generalized. The effect of additional loads with respect to stress generated by heat was also investigated.

Determination of Mechanical Properties of Galvanized Steel Sheets Using Instrumented Indentation Technique and Finite Element Analysis (계장화 압입시험 및 유한요소해석을 이용한 아연도금강판의 기계적 물성 추정)

  • Jin, Ji-Won;Kwak, Sung-Jong;Kim, Tae-Seong;Noh, Ki-Han;Kang, Ki-Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.529-535
    • /
    • 2012
  • This paper deals with the determination of mechanical properties of various galvanized steel sheets that are used for fabricating automobile bodies; the instrumented indentation technique and finite element analysis were used for the determination. First, tensile tests were conducted to obtain the true stress-true strain curves of galvanized steel sheets with various thicknesses. Load-deformation curves were then obtained by using the instrumented indentation testing machine, and they were compared with load-deformation curves obtained by finite element analysis. Further, true stress-true strain curves were obtained at the optimal observation point by finite element analysis.

Study on Obstacle Deflector of a Railway Vehicle Using Tension-type Energy Absorbers (인장형 에너지흡수부재를 이용한 철도차량용 장애물제거기 연구)

  • Kim, Hongeik;Kim, Jinsung;Kwon, Taesoo;Jung, Hyunseung
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.173-181
    • /
    • 2017
  • The obstacle deflector sweeps obstacles off the track or absorbs crash energy with an energy absorber to prevent derailment of a train and to minimize damage and casualties after an accident. In this study, an obstacle deflector and its operational mechanism were designed with a tension-type energy absorber and a 4-bar linkage system. Also, a test method was suggested and verified with FEA (Finite Element Analysis) and UTM (Universal Test Machine) for testing of the static load and energy absorbing ability according to EN 15227 regulations. Through this study, an obstacle deflector that meets the EN 15227 standard was designed and a test method was suggested to adjust the collapse load easily and to verify it experimentally according to the design and verification procedure of the obstacle deflector.

A Multi-Load Shoring Characteristic Using Novel Buck-Boost Chopper Circuit (새로운 승·강압 초퍼 회로를 이용한 부하 다분할 특성)

  • Suh, Ki-Young;Mun, Sang-Pil;Kwon, Soon-Kurl;Lee, Hyun-Woo;Jung, Sang-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.42-48
    • /
    • 2005
  • A DC-DC converter is being widely used for various household appliances and for industry applications. The DC-CC converter is powered from single battery, and the voltage is varied according to the purpose. In the vehicle, various accessories whose electric power is different are being un4 Thus, plural number of DC-DC converter should be provided, so these situations bring complicated circuits, and accordingly, higher cost. Under such backgrounds, in this paper, we propose a novel buck-boost chopper circuit with simply configuration which can supply to two or more different output loads. The propose chewer circuit can control output voltages by controlling duty ratio by using typically two switching devices, which is composed by single boost-switch and single buck-switch. The output voltage can be controlled widely. A few modified circuits developed from the fundamental circuit are represented including the general multi-load circuit. And all this merits and appropriateness was proved by computer simulation and experience.

Test Level of Domestic Concrete Barrier (국내 콘크리트 방호벽의 등급 고찰)

  • Jeon, Se-Jin;Choi, Myoung-Sun;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.113-116
    • /
    • 2008
  • According to a domestic provision, test levels of the barrier are divided into seven categories(SB1 to SB7) and the corresponding crash conditions are specified. Meanwhile, standard types of concrete barriers with different dimensions have been constructed nation wide. Some studies aimed at finding a proper test level of each type of the concrete barrier have been carried out, but the reliable and consistent results have not been fully established yet. The purpose of this study is to find out the test level corresponding to the concrete barrier of type-2 through static test. AASHTO LRFD was referred to for the loading pattern and a magnitude of the load that simulate a vehicle crash assumed. The test results show that the ultimate strength of the type-2 satisfies the load level required for SB5. However, it seems that the type-2 does not comply with SB6, showing some differences in results from previous analytical studies. In order to take advantage of the static test in establishing the test level of the domestic barrier, more detailed provisions should be specified.

  • PDF

Analysis of the Impact of Smart Grids on Managing EVs' Electrical Loads (스마트그리드를 통한 전기자동차의 전력망 영향 관리 효과)

  • Park, Chan-Kook;Choi, Do-Young;Kim, Hyun-Jae
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.767-774
    • /
    • 2013
  • The electricity demand and supply could be off balance if several electric vehicles(EVs) were charged at the same time or at peak load times. Therefore, smart grids are necessary to flatten the EVs' electricity demand and to enable EVs to be used as distributed storage devices as electricity demand from EV-charging increases. There are still few quantitative studies on the impact of smart grids on managing EVs' electrical loads. In this study, we analyzed the quantitative impact of smart grids on managing EVs' electrical loads and suggested policy implications. As a result, it is identified that smart grids can manage effectively EVs' impact on electrical grids. The electricity market structure and regulatory framework should support the demonstration and commercialization of smart grid technologies.