• Title/Summary/Keyword: Vascular circulation

Search Result 217, Processing Time 0.022 seconds

Statins and Clinical Outcomes in Patients With Low to Moderate Risk but With Non-obstructive Carotid Plaques: The SCOPE-CP Study

  • Minjae Yoon;Chan Joo Lee;Sungha Park;Sang-Hak Lee
    • Korean Circulation Journal
    • /
    • v.52 no.12
    • /
    • pp.890-900
    • /
    • 2022
  • Background and Objectives: Some individuals exhibit discrepancies between risk classifications assessed using clinical factors and those obtained by vascular imaging. We aimed to evaluate whether statins provide clinical outcome benefits in patients classified as having low to moderate cardiovascular risk but with carotid plaque. Methods: This was a retrospective propensity score matching study. A total of 12,158 consecutive patients undergoing carotid ultrasound between January 2012 to February 2020 were screened. Individuals with low to moderate cardiovascular risk who were not currently recommended for statin therapy but had carotid plaques were included. Among 1,611 enrolled individuals, 806 (statin group: 403, control group: 403) were analyzed. The primary outcomes were major adverse cardiovascular and cerebrovascular events (MACCEs: cardiovascular death, myocardial infarction, coronary revascularization, and ischemic stroke or transient ischemic attack) and all-cause mortality. Results: During the median follow-up of 6.0 years, the incidence of MACCEs did not differ between the groups (6.1 and 5.7/1,000 person-years in the control and statin groups, respectively; adjusted hazard ratio [HR], 0.95; p=0.90). The incidence of all-cause mortality did not differ (3.9 and 3.9/1,000 person-years, respectively; adjusted HR, 1.02; p=0.97). Kaplan-Meier curves revealed similar rates of MACCEs (log-rank p=0.72) and all-cause mortality (log-rank p=0.99) in the 2 groups. Age and smoking were independent predictors of MACCEs. Subgroups exhibited no differences in clinical outcomes with statin use. Conclusions: Benefit of statin therapy was likely to be limited in low to moderate risk patients with carotid plaques. These results could guide physicians in clinical decision-making regarding cardiovascular prevention.

Cryoballoon Catheter Ablation in Korean Patients With Paroxysmal and Persistent Atrial Fibrillation: One Year Outcome From the Cryo Global Registry

  • Hong Euy Lim;Il-Young Oh;Fred J Kueffer;Kelly Anna van Bragt;Young Keun On
    • Korean Circulation Journal
    • /
    • v.52 no.10
    • /
    • pp.755-767
    • /
    • 2022
  • Background and Objectives: Cryoballoon catheter ablation for the treatment of patients with symptomatic atrial fibrillation (AF) has been adopted globally, but there are limited multicenter reports of 12-month outcomes in the Korean patient population. This analysis evaluated the clinical performance and safety of cryoballoon ablation (CBA) according to standard-of-care practices in Korea. Methods: This evaluation of Korean patients with AF was conducted within the larger Cryo Global Registry, which is a prospective, multicenter, post-market registry. Freedom from a ≥30-second recurrence of atrial arrhythmias (after a 90-day blanking period until 12 months) and procedural safety were examined in subjects treated with CBA at 3 Korean centers. Results: Overall, 299 patients with AF (60±11 years old, 24.7% female, 50.5% paroxysmal AF) underwent CBA using the Arctic Front Advance cryoballoon. Of those, 298 were followed-up for at least 12 months. Mean procedure-, left atrial dwell- and fluoroscopy time was 76±21 minutes, 56±23 minutes, and 27±23 minutes, respectively. Freedom from AF recurrence at 12 months was 83.9% (95% confidence interval [CI], 76.9-88.9%) in the paroxysmal and 61.6% (95% CI, 53.1-69.0%) in the persistent AF cohort. Rhythm monitoring was performed on average 4.7±1.4 times during the follow-up period. Serious device- or procedure-related adverse events occurred in 2 patients (0.7%). The 12-month Kaplan-Meier estimate of freedom from repeat ablation and cardiovascular-related hospitalization was 93.8% (95% CI, 90.4-96.1%) and 89.7% (95% CI, 85.6-92.7%), respectively. Conclusions: CBA is an efficient, effective, and safe procedure for the treatment of AF patients when used according to real-world practices in Korea.

Self-Monitoring of Blood Pressure and Feed-back Using APP in TReatment of UnconTrolled Hypertension (SMART-BP): A Randomized Clinical Trial

  • Dong-Ju Choi;Jin Joo Park;Minjae Yoon;Sung-Ji Park;Sang-Ho Jo;Eung Ju Kim;Soo-Joong Kim;Sungyoung Lee
    • Korean Circulation Journal
    • /
    • v.52 no.10
    • /
    • pp.785-794
    • /
    • 2022
  • Background and Objectives: Self-monitoring of blood pressure (SMBP) is a reliable method used to assess BP accurately. However, patients do not often know how to respond to the measured BP value. We developed a mobile application-based feed-back algorithm (SMBP-App) for tailored recommendations. In this study, we aim to evaluate whether SMBP-App is superior to SMBP alone in terms of BP reduction and drug adherence improvement in patients with hypertension. Methods: Self-Monitoring of blood pressure and Feed-back using APP in Treatment of UnconTrolled Hypertension (SMART-BP) is a prospective, randomized, open-label, multicenter trial to evaluate the efficacy of SMBP-App compared with SMBP alone. Patients with uncomplicated essential hypertension will be randomly assigned to the SMBP-App (90 patients) and SMBP alone (90 patients) groups. In the SMBP group, the patients will perform home BP measurement and receive the standard care, whereas in the SMBP-App group, the patients will receive additional recommendations from the application in response to the obtained BP value. Follow-up visits will be scheduled at 12 and 24 weeks after randomization. The primary endpoint of the study is the mean home systolic BP. The secondary endpoints include the drug adherence, the home diastolic BP, home and office BP. Conclusions: SMART-BP is a prospective, randomized, open-label, multicenter trial to evaluate the efficacy of SMBP-App. If we can confirm its efficacy, SMBP-App may be scaled-up to improve the treatment of hypertension.

Revascularization Strategies in Patients With ST-Segment Elevation Myocardial Infarction and Multivessel Disease: Is FFR-Guided Strategy Still Valuable?

  • Doosup Shin;Tae-Min Rhee;Seung Hun Lee ;Joo Myung Lee
    • Korean Circulation Journal
    • /
    • v.52 no.4
    • /
    • pp.280-287
    • /
    • 2022
  • Several studies have shown the benefit of complete revascularization (CR) over culprit-only percutaneous coronary intervention (PCI) in patients with ST-segment elevated myocardial infarction (STEMI) and multivessel disease (MVD). Nevertheless, optimal strategy to select targets for non-culprit PCI has not been clarified. In this paper, we critically discuss and compare the safety and efficacy of different strategies for CR in patients with STEMI and MVD using a Bayesian network meta-analysis including all previous randomized controlled trials (RCTs). In Bayesian network meta-analysis of 13 RCTs, culprit-only PCI was associated with higher risk of major adverse cardiac events (MACE), compared with angiography-guided or fractional flow reserve (FFR)-guided CR strategies. However, there was no significant difference between angiography-guided and FFR-guided CR strategies in the risk of MACE and its individual components including all-cause death, cardiac death, myocardial infarction (MI), and revascularization. These evidence support that both angiography-guided and FFR-guided complete revascularization strategies would be reasonable treatment option in patients with STEMI and MVD. If the non-culprit lesion is severe on visual assessment, angiography-guided PCI can be considered. If the non-culprit lesion is intermediate in severity or unclear based on visual assessment, FFR-guided strategy can be used as a reliable and objective tool, providing similar benefits with less stents compared with an angiography-guided strategy. Further RCT is needed to evaluate direct comparison between angiography-guided and FFR-guided CR strategies in patients with STEMI and MVD. Ongoing FRAME-AMI trial (NCT02715518) will provide more evidence regarding this issue.

Deep Learning-Based Lumen and Vessel Segmentation of Intravascular Ultrasound Images in Coronary Artery Disease

  • Gyu-Jun Jeong;Gaeun Lee;June-Goo Lee;Soo-Jin Kang
    • Korean Circulation Journal
    • /
    • v.54 no.1
    • /
    • pp.30-39
    • /
    • 2024
  • Background and Objectives: Intravascular ultrasound (IVUS) evaluation of coronary artery morphology is based on the lumen and vessel segmentation. This study aimed to develop an automatic segmentation algorithm and validate the performances for measuring quantitative IVUS parameters. Methods: A total of 1,063 patients were randomly assigned, with a ratio of 4:1 to the training and test sets. The independent data set of 111 IVUS pullbacks was obtained to assess the vessel-level performance. The lumen and external elastic membrane (EEM) boundaries were labeled manually in every IVUS frame with a 0.2-mm interval. The Efficient-UNet was utilized for the automatic segmentation of IVUS images. Results: At the frame-level, Efficient-UNet showed a high dice similarity coefficient (DSC, 0.93±0.05) and Jaccard index (JI, 0.87±0.08) for lumen segmentation, and demonstrated a high DSC (0.97±0.03) and JI (0.94±0.04) for EEM segmentation. At the vessel-level, there were close correlations between model-derived vs. experts-measured IVUS parameters; minimal lumen image area (r=0.92), EEM area (r=0.88), lumen volume (r=0.99) and plaque volume (r=0.95). The agreement between model-derived vs. expert-measured minimal lumen area was similarly excellent compared to the experts' agreement. The model-based lumen and EEM segmentation for a 20-mm lesion segment required 13.2 seconds, whereas manual segmentation with a 0.2-mm interval by an expert took 187.5 minutes on average. Conclusions: The deep learning models can accurately and quickly delineate vascular geometry. The artificial intelligence-based methodology may support clinicians' decision-making by real-time application in the catheterization laboratory.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

Quantitative Analysis of Thallium-201 Myocardial Tomograms (Thallium-201 심근 단층영상의 정량적 분석)

  • Kim, Sang-Eun;Nam, Gi-Byoung;Choi, Chang-Woon;Choi, Kee-Joon;Lee, Dong-Soo;Sohn, Dae-Won;Ahn, Cu-Rie;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Choi, Yun-Shik;Seo, Jung-Don
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.165-176
    • /
    • 1991
  • The purpose of this study was to assess the ability of quantitative Tl-201 tomography to identify and localize coronary artery disease (CAD). The study population consisted of 41 patients (31 males, 10 females; mean age $55{\pm}7$ yr) including 14 with prior myocardial infarction who underwent both exercise Tl-201 myocardium SPECT and coronary angiography for the evaluation of chest pain. From the short axis and vertical long axis tomograms, stress extent polar maps were generated by Cedars-Sinai Medical Center program, and the % stress defect extent (SDE) was quantified for each coronary artery territory. For the purpose of this study, the coronary circulation was divided into 6 arterial segments, and the "myocardial ischemic score" (MIS) was calculated from the coronary angiogram. Sensitivity for the detection of CAD ($\geq50%$ coronary stenosis by angiography) by angiography) by stress extent polar map was 95% in single vessel disease, and 100% in double and triple vessel deseases. Overall sensitivity was 97%. Sensitivity and specificity for the detection of individual diseased vessels were, respectively, 87% and 90% for the left anterior descending artery (LAD), 36% and 93% for the left circumflex artery (LCX), and 71% and 70% for the right coronary artery (RCA). Concordance for the detection of individual diseased vessels between the coronary angiography and stress polar map was fair for the LAD (kappa=0.70), and RCA (kappa=0.41) lesions, whereas it was poor for the LCX lesions (kappa : 0.32). There were siginificant correlations between the MIS and SDE in LAD (rs=0.56, p=0.0027), and RCA territory (rs=0.60, p=0.0094). No significant correlation was found in LCX territory. When total vascular territories were combined, there was a significant correlation between the MIS and SDE (rs=0.42, p=0.0116). In conclusion, the quantitative analysis of Tl-201 tomograms appears to be accurate for determining the presence and location of CAD.

  • PDF

Surgical Observation on the Vascular Diseases -A Report of 174 Cases- (혈관질환의 외과적 고찰)

  • Chae, Hurn;Lee, Young;Rho, Joon Ryang;Kim, Chong Whan;Suh, Kyung Phill;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.10-19
    • /
    • 1976
  • One hundred and seventy-four patients were treated in this Department since 1956. One hundred and fifteen patients of them were surgically treated. They were classified on the basis of the disease entity as follows; 48 case of thrombo-angiitis obliterance, 8 cases of Leriche syndrome, 12 cases of arterial embolism, 36 arterial aneurysm, 5 arterio-venous fistula, 15 arterial and venous injuries, 8 pulseless diseases, 2 coarctation of aortas, 15 varicose veins, 12 thrombophlebitis, 9 superior venacaval syndromes, 2 inferior vena caval obstructions and Raynaud's diseases. All the cases of the Burger's diseases were males, and half of them were in the fourth decades, 39 cases underwent undergone unilateral or bilateral sympathectomies. All the Leriche syndromes were males aged over fifty. Three cases out of six were suffering from diabetes mellitus. 2 cases underwent aorto-femoral bypass graft with Y-shaped dacrons. And two embolectomies were performed in 2 cases. Eight cases of arterial embolisms among 12 had mitral valvular diseases with auricular fibrillation The most common site of lodgement of emboli was femoral artery. Nine out of 14 underwent embolectomies with Fogarty catheters. There were 14 peripheral arterial aneurysms, 16 thoracic and/or abdominal aortic aneurysms, and 4 dissecting aneurysms. Most frequent cause of peripheral arterial aneurysms were external trauma. Thoracic and abdominal aortic aneurysms were non-traumatic. And four cases of the dissecting aneurysms had significant hypertension and aged over fifty. Among 5 cases of arteriovenous fistulas, 2 cases hand typical Branham's sign, and they were normalized after operation. Eight cases of pulseless disease were females and aged from three to twenty-five. Three out of them were treated surgically using dacron prosthetic grafts, but the results of the surgery were variable and not satisfactory. A case of coarctation of aorta was treated surgically with an excellent result. Fourteen out of 15 varicose veins underwent ligation of the saphenous vein system, exstirpation of the varicose veins, stripping or some combination of these methods. Two cases of superior vena caval syndromes were operated by bypass graft between the left innominate vein and the right auricle. Two cases of inferior vena caval obstructions were operated upon through right atrial route using extracorporial circulation. All the four cases of vena caval obstructions showed excellent results postoperatively. Two cases out of 12 thrombophlebitis underwent thrombectomies. One of two Raynaud's diseases was surgically treated with an excellent result.

  • PDF

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

Neuroprotective Effect of Hwangryunhaedok-tang on the Brain Ischemia Induced by Four-Vessel Occlusion in Rats (황련해독탕(黃連解毒湯)의 4-VO로 유발한 흰쥐뇌허혈에 대한 신경보호효과)

  • 이민정;김영옥;이강진;유영법;김선여;김성수;김호철
    • The Journal of Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.161-168
    • /
    • 2002
  • Objectives: Hwangryunhaedok-tang (Huang-lian-jie-du-tang, HRHDT, 黃連解毒湯) is a traditional Korean herbal medicine that is formulated with Coptidis Rhizoma, Phellodendri Cortex, Scutellariae Radix and Gardeniae Fructus. HRHDT is cold (寒) and bitter (苦) in nature and has general properties of clearing heat and detoxifying (淸熱解毒), strengthening the stomach and settling the liver (健胃平肝), and reducing inflammation, fever and swelling. This formula can prevent and treat artherosclerosis, hyperplasia of the endothelium, cerebral fluid circulation, cerebral vascular deterioration through aging, impairment of neurotransmitters, or disruption of the functioning of the cerebral cortex following infection or trauma. The purpose of the study reported here was to determine the neuroprotective effect of HRHDT on global ischemia induced by 4-vessel occlusion in Wistar rats. Methods: HRHDT extract was lyophilized after extraction with 85% methanol and 100% water. Rats were induced to 10 minutes of forebrain ischemia by 4-vessel occlusion (4-VO) and reperfused again. HRHDT was administered with a dose of 100 mg/kg, and 500 mg/kg of 85% methanol extracts and 100 mg/kg of 100% water extracts, respectively, at 0 min and 90 min after 4-VO. Rats were killed at 7 days after ischemia and the number of CA1 pyramidal neurons was counted in hippocampal sections stained with cresyl violet. Results: Body temperature of animals showed no significant difference between saline-treated groups and HRHDT extracts-treated groups until 5 hours of reperfusion. This result indicated that neuroprotective effects of HRHDT extracts were not due to hypothermic effects. The administration of HRHDT showed a significant neuroprotective effect on hippocampal CA1 neurons at 7 days after ischemia compared to the saline-treated group (P<0.001). HRHDT methanol extracts of 100 mg/kg, 500 mg/kg and HRHDT water extracts of 100 mg/kg showed 88.5%, 98.3% and 95.1 % neuroprotection, respectively. Conclusions: The results of this study demonstrate that administration of HRHDT is highly effective in reducing neuronal damage in response to transient global cerebral ischemia. HRHDT may involve many mechanisms that might account for its high degree of efficacy. A number of factors including free radicals, glutamate, calcium overload, NO, and various cytokines have been proposed to have an important role in causing neuronal death after short periods of global ischemia. Further studies are needed to know the neuroprotective mechanisms of HRHDT.

  • PDF