• Title/Summary/Keyword: Vascular Graft

Search Result 287, Processing Time 0.024 seconds

Reconstruction of Tibia Defect with Free Flap Followed by Ipsilateral Fibular Transposition (유리 피판술과 동측 비골 전위술을 이용한 경골 결손의 재건)

  • Chung, Duke-Whan;Park, Jun-Young;Han, Chung-Soo
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.42-49
    • /
    • 2005
  • Between June 1989 and may 2004 Ipsilateral vascularized fibular transposition was performed on nine patients with segmental tibial defects combined with infection following trauma. Ipsilateral vascularized fibular graft was performed on two or three stage according to the degree of infection. Initially free vascular pedicled graft was done followed by ipsilateral vascularized fibular graft. Type of free flap used is scapular free flap 3 cases, latissimus dorsi free flap 5 cases and dorsalis pedis flap 1 cases. The patients were followed for an average of 3.4 years. the average time to union was 6.7 months, and in all patients the graft healed in spite of complication. Complication was free flap venous thrombosis in 1 cases, persistent infection in 1 cases, delayed bony union at the distal end of fibular graft in 2 cases. The results showed that more faster bony union was seen in which cases firmly internally fixated and more faster hypertrophy of graft in which cases was permitted to ambulate on early weight bearing and more faster healing in which cases debrided more meticulously. Reconstruction of tibia defect with free flap followed by Ipsilateral fibular transposition is a useful and safe method to avoid the potential risk of infection for patients with tibial large bone defect and soft tissue defect associated with infection.

  • PDF

APPLICATION OF ARTIFICIAL DERMIS($Terudermis^{(R)}$) AND SPLIT THICKNESS SKIN GRAFT ON THE DONOR SITE OF RADIAL FOREARM FLAP (인공진피($Terudermis^{(R)}$)와 부분층 피부이식을 이용한 전완피판 공여부 수복)

  • Oh, Jung-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.3
    • /
    • pp.227-232
    • /
    • 2007
  • The radial forearm fasciocutaneous flap(RFFF) is a well-known flap for the reconstruction of oral and maxillofacial defects. It was first described by Yang et al. in 1981 and Soutar et al. developed it for the reconstruction of intraoral defect. RFFF provides a reliable, thin, and pliable soft tissue/skin paddle that is amenable to sensate reconstruction. It also has a long vascular pedicle that can be anastomosed to any vessel in either the ipsilateral or contralateral neck. However, split thickness skin graft(STSG) is most commonly used to cover the donor site, and a variety of donor site complications have been reported, including delayed healing, swelling of the hand, persistent wrist stiffness, reduced hand strength, and partial loss of the graft with exposure of the forearm flexor tendon. Various methods for donor site repair in addition to STSG have been developed and practiced to minimize both functional and esthetic morbidity, such as direct closure, V-Y closure, full thickness skin graft, tissue expansion, acellular dermal graft. We got a good result of using artificial dermis($Terudermis^{(R)}$) and secondary STSG for the repair of RFFF donor site defect esthetically and report with a review of literature.

Clinical Characteristics of Patients Treated in an Emergency Center for Vascular Trauma (일개 응급센터에 내원한 외상성 혈관손상 환자의 임상적 특성)

  • Park, Yong Myeon;Yeom, Seok Ran;Jeong, Jin Woo;Han, Sang Kyun;Jo, Suck Ju;Ryu, Ji Ho;Kim, Yong In;Chung, Sung Woon
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.5-11
    • /
    • 2009
  • Purpose: The mortality and the amputation rates due to vascular trauma remain high despite advanced vascular surgical techniques and supportive management. The clinical features of patients with vascular trauma have not been well studied in the Korean population. The aim of this study was to analyze the clinical characteristics of patients with vascular trauma and to develop a database and guidelines for improving the outcomes of treatment. Methods: The medical records of 37 patients with traumatic vascular injuries who had visited in an emergency center between January 2002 and December 2006 were retrospectively reviewed and statistically analyzed. Results: The mean age was 37.8 years, and the male-to-female ratio was 5.2 : 1. The mechanism of vascular trauma was penetrating in 18 patients and blunt in 19 patients. Upper extremities were most frequently injured (39.4%). The treatment methods were primary repair in 21 patients, exploratory laparotomies in 7, radiological interventions in 3, resections and graft interpositions of the pseudoaneurysm in 3, observations in 3 and a bypass graft in 1. Four out of the 37 patients died, and three of these who died had injuried abdominal vessels. Twenty-five of the patients recovered completely, four expired, seven had neuropathy in the course of treatement, one had his limb amputated, and one experienced wound necrosis. Conclusion: Peripheral vessel injuries are commonly accompanied by nerve, muscle, or tendon injuries. Patients without associated fractures or compartment syndrome had good prognosis. Although the time intervals from hospital arrival to definite treatment were the shortest among patients with blunt abdominal vascular injuries, three expired. Therefore, we offer a 'ritical pathway'to improve the outcomes of patients with blunt abdominal vascular injury.

Affinity of Endothelial Cells to a Polyurethane Vascular Graft: A Preliminary Animal Study (폴리우레탄 인공혈관에 대한 혈관내피세포의 친화성: 예비동물실험)

  • Ahn, Seung Hyun;Jun, Young min;Chang, Hak;Park, Chung Hee;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.380-384
    • /
    • 2009
  • Purpose: Autologous vessels remain the gold standard for vascular grafts in microanastomoses. However, they are sometimes unavailable and have a limited long - term patency. Synthetic vessels have high success rates in large - diameter reconstructions but failed when used as small - diameter grafts due to graft occlusion. It has been proved that endothelial cell seeding improves prosthesis performance and long - term patency. Among polyurethane, PET and ePTFE, polyurethane has the best affinity to endothelial cells and mechanical properties closest to human vessels. We examined the ability of endothelial cells to attach to a polyurethane graft manufactured by the electrospinning method. Methods: Endothelial cells, which were cultured from porcine internal jugular veins, were attached to polyurethane grafts with an internal diameter of 3 mm. The same cells were attached to allogeneic decellularized porcine internal carotid artery grafts as controls. Both of the 10 mm - long grafts were exposed to endothelial cells in a well for 1 hour. Each well contained $2{\times}10^5$ endothelial cells. The graft materials were rotated through 90 degrees every 15 minutes in order to minimize the effect of gravity. The extent of cell attachment was examined with the MTT assay. Results: The MTT assay showed good incorporation of endothelial cells into both grafts. For the evaluation of affinity, the number of attached cells was counted at 10 fields of microscopic examination with ${\times}40$ magnification. Endothelial cells adhered more to polyurethane grafts (mean, $127.4{\pm}6.2cells$) compared to porcine artery grafts (mean $45.8{\pm}5.1cells$)(p<0.05,Mann - Whitney test). Conclusion: In this study, we attached porcine endothelial cells to polyurethane grafts, manufactured by electrospinning. The grafts exhibited a better affinity to endothelial cells than allogeneic decellularized porcine internal carotid artery grafts. It is suggested that the time required for endothelial cells to attach to decellulized artery grafts may be longer than that which is required for attachment to polyurethane grafts.

Microsurgical Reconstruction of Giant Cell Tumor of Distal Epiphysis of Radius (미세 수술을 이용한 광범위한 요골 원위 골단부 거대세포종의 재건술)

  • Kwon, Boo-Kyung;Chung, Duke-Whan;Han, Chung-Soo;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.100-107
    • /
    • 2007
  • Treatment of giant cell tumor of distal radius can be treated in several ways according to the aggressiveness of the tumor. But the management of giant cell tumor involving juxta-articular portion has always been a difficult problem. In some giant cell tumors with bony destruction, a wide segmental resection may be needed for preventing to recur. But a main problem is preserving of bony continuity in bony defect as well as preservation of joint function. We have attempted to overcome these problems by using a microvascular technique to transfer the fibula with peroneal vascular pedicle or anterior tibial vessel as living bone graft. From April 1984 to July 2005, we performed the reconstruction of wide bone defect after segmental resection of giant cell tumor in 14 cases, using Vascularized Fibular Graft, which occur at the distal radius. VFG with peroneal vascular pedicle was in 8 cases and anterior tibial vessel was 6 cases. Recipient artery was radial artery in all cases. Method of connection was end to end anastomosis in 11 cases, and end to side in 3 cases. An average follow-up was 6 years 6 months, average bone defect after wide segmental resection of lesion was 6.8 cm. All cases revealed good bony union in average 6.5 months, and we got the wide range of motion of wrist joint without recurrence and serious complications. Grafted bone was all alive. In functional analysis, there was good in 7 cases, fair in 4 cases and bad in 1 case. Pain was decreased in all cases but there was nearly normal joint in only 4 cases. Vascularized fibular graft around wrist joint provided good functional restoration without local recurrence.

  • PDF

Histologic observation of regenerated bone in human intraosseous lesion following guided tissue regeneration with calcium carbonate implant and autogenous bone graft (Calcium carbonate 및 자가골 이식술을 동반한 조직유도재생술후 생검을 통한 재생골의 조직학적 관찰)

  • Lee, Yong-Moo;Han, Soo-Boo;Um, Heung-Sik;Kim, Dang-Kyoon
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.263-273
    • /
    • 1998
  • For histologic observation of the regenerated bone following guided tissue regeneration (GTR) using ePTFE membranes with calcium carbonate implant and autogenous bone graft, biopsies were collected from 2 patients during 5-year-postoperative surgical reentry. In both combined cases with guided tissue regeneration in conjunction with calcium carbonate implant and autogenous bone graft, significant bone fill and gain in probing attachment level was observed. In histologic examination, specimen in GTR case with calcium carbonate grafting was composed of a dense bone containing vascular channel with lamellar structure and viable bone cells in lacunae, however considerable calcium carbonate particles remained unresorbed and isolated from regenerated bone by the dense cellular and fibrous connective tissue. No formative cells could be seen in contact with remained calcium carbonate particles. In GTR case with autogenous bone grafting, specimen show was composed of a dense lamellar bone containing vascular channel, which showed normal alveolar bone architectures. The present observation indicate that guided tissue regeneration in conjunction with grafting, especially autogenous bone graft, has highly osteogenic potential, however resorbable calcium carbonate granules were not completely resorbed at 5 year postimplantation.

  • PDF

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Development of Porous polyurethane Arterial-Venous Shunt by Thermal Control (온도 조절을 통한 다공성 폴리우레탄 동정맥 누관의 개발)

  • Jeong, J.S.;Ryu, G.H.;Kim, J.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.478-481
    • /
    • 1997
  • A technique or the preparation of porous polyurethane vascular prostheses was investigated. Small-diameter vessels are not in general clinical use due to their limited long-term biocompatibility and low patency rates in experimental trial. These limits are mainly due to the failure of mechanical unction of the vascular grafts. This failure has been suggested to result partially from compliance mismatch. The long-term patency is considered to depend critically on the properties of the material and the fabrication process of the graft. So the control of pores is very important and main points to develop a available vascular grafts. Two-kind polymer sheets was compared. One was the porous PU-sheet made at room temperature by the solvent/non-solvent exchange. And the other was the porous PU-sheet which was fabricated by thermal phase transition and solvent-/non-solvent exchange using the thermal controller. The polymer sheets had a uniform pore size and pore occupation. According to the result of the above experiments, polyurethane solution was injected into a mold designed or U-type tube. The average pore size and pore occupation were easily changed by changing polyurethane concentration, freezing temperature, and methods. This technique can give a proper pore size ($10{\sim}45\;{\mu}m$) or tissue in growth, and suitable compliances or matching with arteries and veins. Besides, the fabrication of more complicated shaped vessels such as the U-type vascular grafts is easily controlled by using the fixed mold. this method might give a desired compliant graft or artificial implantation with the presently valid medical polymers.

  • PDF

Vascular Augmentation in Renal Transplantation: Supercharging and Turbocharging

  • Jeong, Euicheol C.;Hwang, Seung Hwan;Eo, Su Rak
    • Archives of Plastic Surgery
    • /
    • v.44 no.3
    • /
    • pp.238-242
    • /
    • 2017
  • The most common anatomic variant seen in donor kidneys for renal transplantation is the presence of multiple renal arteries, which can cause an increased risk of complications. Accessory renal arteries should be anastomosed to the proper source arteries to improve renal perfusion via the appropriate vascular reconstruction techniques. In microsurgery, 2 kinds of vascular augmentation methods, known as 'supercharging' and 'turbocharging,' have been introduced to ensure vascular perfusion in the transferred flap. Supercharging uses a distant source of the vessels, while turbocharging uses vascular sources within the same flap territory. These technical concepts can also be applied in renal transplantation, and in this report, we describe 2 patients who underwent procedures using supercharging and turbocharging. In one case, the ipsilateral deep inferior epigastric artery was transposed to the accessory renal artery (supercharging), and in the other case, the accessory renal artery was anastomosed to the corresponding main renal artery with a vascular graft (turbocharging). The transplanted kidneys showed good perfusion and proper function. No cases of renal failure, hypertension, rejection, or urologic complications were observed. These microsurgical techniques can be safely utilized for renal transplantation with donor kidneys that have multiple arteries with a lower complication rate and better outcome.

Deep Vein as a Graft Conduit (도관으로 사용된 심부정맥)

  • Yie, Kil-Soo;Cheon, Sung-Bin;Oh, Won-Sub;Ryu, Se-Min;Lee, Bong-Ki;Kim, Hyung-Rae;Kim, Keun-Woo
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.441-446
    • /
    • 2010
  • The ideal graft requires acceptable size, less tissue toxicity, resistance to infection, and long-term durability. Great saphenous veins are gaining popularity as acceptable graft conduits, but they require time to grow in caliber. We report 2 cases of graft bypass and reconstruction using superficial femoral veins to acheive immediate high-flow patency.