• 제목/요약/키워드: Varied Section

검색결과 285건 처리시간 0.033초

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.

3성분 혼합냉매 R-407c의 수평 마이크로핀관내 응축압력강하에 관한 연구 (Study on the pressure drop of ternary refrigerant R-407c during condensation inside horizontal micro-fin tubes)

  • 정재천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.210-218
    • /
    • 1998
  • Experimental results for forced convection condensationof Refrigerant-22 and ternary Refrigerant-407c(HFC-32/125/134a 23/25/52 wt%) considered as a substitute R-22 inside horizontal micor-fin tubes are presented. The test section was horizontal double-tubed counterflow condenser with a length 4000 mm micro-fin tube having 9.53 mm OD., 0.2 mm fin height and 60 fins. The refrigerants R-22 and R-407c were cooled by a coolant circulated in a surrounding annulus. The range of parameters of mass velocity was varied from 102.1 to 301.0kg/($\textrm{m}^{2}.s$) with inlet quality 1.0. Both refrigerant R-22 and its alternative refrigerant R-407c were tested within the same range of parameters. At the given experimental conditions for R-22 and R-407c the pressure drops for R-407c were considerably higher than those for R-22 at micro-fin tubes. Over the mass velocity range tested the PF(penalty factor)was lower than the increasing ratio of heat transfer area by fins. Based on the data correlation was proposed for predicting the frictional pressure drops for R-22 and R-407c for a duration of condensation inside a horizontal micro-fin tube.

  • PDF

석고주조(石膏鑄造)한 Al-8.6% Si-3.6% Cu 합금(合金)의 기계적(機械的) 성질(性質)에 관(關)한 연구(硏究) (A Study on the Mechanical Properties of Al-8.6% Si-3.6% Cu Alloy Cast in Plaster Mold)

  • 여인동;김동옥;강인찬
    • 한국주조공학회지
    • /
    • 제4권4호
    • /
    • pp.5-13
    • /
    • 1984
  • This paper is presented for showing the effect of cooling rate on dendrite arm spacing, correlated with the chilling power of molding materials (conventional plaster, foamed plaster, silica sand) and section thickness, and also showing relationship between dendrite arm spacing and mechanical properties for an aluminum - 8.6 percent silicon - 3.6 percent copper alloy. Local solidification time $(t_f)$ and secondary dendrite arm spacing (d) could be varied widely in accordance with the molding materials and casting thickness, and the following relationship is obtained: $d=9.4t_f\;^{0.31}$ A good correlation between dendrite arm spacing and mechanical properties such as ultimate tensile strength, yield strength, hardness was found, that is, mechanical properties decreased in a linear manner with increase in log of secondary dendrite arm spacing. Ultimate tensile strength in conventional plaster mold casting decreased by 15 percent comparing with the sand casting, where as in foamed plaster mold casting, it decreased by 30 percent comparing with the sand casting. From those results, it has been verified that DAS might be the most representative parameter for predicting mechanical properties varing with the different cooling condition.

  • PDF

아치형 연동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Multi-Span Arched Greenhouses)

  • 이현우;이석진
    • 한국농공학회지
    • /
    • 제38권2호
    • /
    • pp.145-151
    • /
    • 1996
  • Wind force coefficients of multi-span arched greenhouses with respect to wind direction of $0^{\circ}$ and $30^{\circ}$ were estimated to give more reasonable coefficient. The conventional and subdivided division types of wind force coefficient distribution diagrams were constructed by using the wind tunnel experimental data. Bending moments on the greenhouses were determined through structural analysis using obtained wind force coefficients, and were analyzed. Because actual wind pressure values on a face of greenhouse varied with locations, the more divisions of wind force coefficient distribution were subdivided, the better distribution type was coincided with actual state. In order to calculate the more accurate section force occurred on the arched greenhouse by the wind loads, it was recommendable that the wind force coefficient distribution should take more subdivision type. The maximum bending moment at the multi-span greenhouse frame at wind direction of $30^{\circ}$ was greater than that at O。, therefore the wind force coefficient at inclined wind direction to the wall was needed to be considered for the multi-span greenhouse structural design.

  • PDF

압축토양의 투수성과 수도생육 및 수확량에 관한 연구 (A Study on the Effect of the Permeability to Yield Weight of Paddy Rice on the Compressed Soil)

  • 조형용
    • 한국농공학회지
    • /
    • 제15권2호
    • /
    • pp.2968-2979
    • /
    • 1973
  • The aim of this study was to bring light on the effect of permeability to yield weight of paddy rice on the compressed soil. a) The percolation volume during the growth of paddy rice reduced, while the degree of compression on soil column increased and varied by the evaporation and absorption volumn. b) The percolation volume in the natural soil column was notably low compared with that of in the artificial and had little influence to the variation of permeabilty by compression. c) The results in growth of paddy rice were best on the section of low compression and the yield weight reduced, while the degree of compression on the soil column increased. d) The relationship between the yield weight and percolation volumn, under the condition when percolation volume is 1mm/day, had little difference in the yield weight but immediately reduced under $0.5{\sim}1.0mm/day$. The consequences of investigation are not so perfect, but have done my best to get some new data for effect on additional yield by inquiring into influences of permeability to the yield weight of paddy rice on compressed paddy field. I will have a great pleasure if treatise helps investigaters or the men of affairs in this field.

  • PDF

원관내의 이상선회유동 특성에 관한 연구 (The study on the Two-Phase Swirl Flow Characteristics in Cylindrical Pipe)

  • 차경옥;김재근
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.187-197
    • /
    • 1996
  • Many investigations have been made to determine the pressure drop and heat transfer characteristics for single phase flow in tape generated swirl flow. But few studies have been carried out to investigate the heat transfer in two component, two phase swirl flow with non-boiling. An experimental study has been conducted to determine the effects of tape twist ratios on two phase convective heat transfer coefficients, pressure drop, and void fraction distribution in a non-boiling, air-water, two phase flow. The flow conditions were both swirl and non swirl flows. The internal diameter of the test section is 42.5mm. The tape twist ratios of pitch to diameter ratio varied from 4.0 to 10.6. The heating conditions were isothermal and nonisothermal. The flow patterns identified with experiments were bubbly, bubbly-slug, slug, and slug-annular flow in up-flow. This study has concluded that no significant difference in void fraction distribution were observed both isothermal and nonisothermal conditions, the pressure drop for two phase flow with twisted tape swirler increase as the tape twist ratio decrease, and that values of two phase heat transfer coefficient increase when the tape twist ratio decreases.

  • PDF

Experimental behaviours of steel tube confined concrete (STCC) columns

  • Han, Lin-Hai;Yao, Guo-Huang;Chen, Zhi-Bo;Yu, Qing
    • Steel and Composite Structures
    • /
    • 제5권6호
    • /
    • pp.459-484
    • /
    • 2005
  • In recent years, the use of steel tube confined concrete (STCC) columns has been the interests of many structural engineers. The present study is an attempt to study the monotonic and cyclic behaviours of STCC columns. For the monotonic behaviours, a series of tests on STCC stub columns (twenty one), and beam-columns (twenty) were carried out. The main parameters varied in the tests are: (1) column section types, circular and square; (2) tube diameter (or width) to thickness ratio, from 40 to 162, and (3) load eccentricity ratio (e/r), from 0 to 0.5. For the cyclic behaviours, the test parameters included the sectional types and the axial load level (n). Twelve STCC column specimens, including 6 specimens with circular sections and 6 specimens with square sections were tested under constant axial load and cyclically increasing flexural loading. Comparisons are made with predicted column strengths and flexural stiffness using the existing codes. It was found that STCC columns exhibit very high levels of energy dissipation and ductility, particularly when subjected to high axial loads. Generally, the energy dissipation ability of the columns with circular sections was much higher than those of the specimens with square sections. Comparisons are made with predicted column strengths and flexural stiffness using the existing codes such as AIJ-1997, AISCLRFD- 1994, BS5400-1979 and EC4-1994.

고대 안료의 성분분석 연구-쌍계사 탱화 안료를 중심으로 (A study on the analysis of ancient pigments-Focus on the Buddha pigments at the Ssanggye temple)

  • 한민수;홍종욱
    • 보존과학연구
    • /
    • 통권24호
    • /
    • pp.131-152
    • /
    • 2003
  • In ancient times, many kinds of different inorganic pigments were used as colorants for making objects. These pigments are still evidentin well known objects such as Danchung, mural painting and Buddhist painting. This study discusses the results obtained from an analysis of the pigments used on the Buddha pigments. The results can be briefly summarized as below; Firstly, the microcrystalline structures revealed on the cross section of analyzed pigments, samples of which were taken from various parts of Buddha pigments show that different sizes and shapes of pigment particle were used for different purposes such as coloring, toning of the pigments. The arrangement of pigments and their usages are varied according to the owner temples and the place where it was created. Secondly, a result of the analysis on the composition and structure of the pigments shows that the main components in their composition are: Red pigments - Red lead($Pb_3O_4$) and Cinnabar(HgS)Green pigments - Malachite[$CuCO_3$.$Cu(OH)_2$] and Prussian Blue[$Fe4(Fe(CN)_6)_2$]Gold pigments - pure gold(Au)Yellow pigments - Orpiment($A_s2S_3)White pigments - Lead Cyanamide[$Pb_3(CO_3)_2(OH)_2]Ultramarine pigments - Azulite[$Cu_3(CO_3)_2(OH)_2]Especially, we knew that pigments used on the Ssanggye temple not repaired to the artificial synthetic pigment

  • PDF

종합병원 외래진료부의 공간구성과 규모계획에 관한 조사연구 - 최근 계획된 500병상 이상 규모의 종합병원을 중심으로 - (A Study on the Spatial Organization of Outpatient Department in General Hospital - Focused on the Latest Planned General Hospital of Scale more than 500 Beds -)

  • 손재원;이특구
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제13권2호
    • /
    • pp.53-60
    • /
    • 2007
  • Various changes in medical environments including growing elderly population, chronic diseases, deepening competition among hospitals since opening to foreign medical service, economic strategy for improvement of profit system have caused hospitals to be specialized. In this backgrounds, the purpose of this study is to receive basic data for architectural planning on the spatial organization of outpatient department in general hospital. The results of this study were as follows; First, major changes of outpatient department in general hospital are composed of 'co-work in medical examination and treatment', 'decentralization of diagnosis and treatment(D/T)' and 'patient-oriented medical service'. Changes by co-work system include appearance of medical offices for co-work, activation of specialized clinics, grouping of E/T section for outpatient and various types of specialized centers. Second, the grouping of E/T sections means the modification of E/T system and organization in general hospitals, and a new spatial organization will be needed. Third, the types of specialized centers are getting varied. they are classified into several types including disease-resource, social stratum-resource, human organ-resource, health-resource, rehabilitation-resource, alternative medical center and so on.

  • PDF

브레이징식 동세관내 CO2의 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of CO2 in a Brazing Type Small Diameter Copper Tube)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.827-834
    • /
    • 2009
  • The cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a brazing type small diameter tube as a test section. The mass flux of $CO_2$ is $400{\sim}1600$ [kg/$m^2s$], the mass flowrate of coolant were varied from 0.15 to 0.3 [kg/s], and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The cooling heat transfer coefficients of the brazing type small diameter copper tube is about $4{\sim}11.7%$ higher than that of the conventional type small diameter copper tube. In comparison with test results and existing correlations, correlations failed to predict the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube. therefore, it is necessary to develope reliable and accurate predictions determining the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube.