• Title/Summary/Keyword: Variable frequency control

Search Result 532, Processing Time 0.022 seconds

Modified sigmoid based model and experimental analysis of shape memory alloy spring as variable stiffness actuator

  • Sul, Bhagoji B.;Dhanalakshmi, K.
    • Smart Structures and Systems
    • /
    • v.24 no.3
    • /
    • pp.361-377
    • /
    • 2019
  • The stiffness of shape memory alloy (SMA) spring while in actuation is represented by an empirical model that is derived from the logistic differential equation. This model correlates the stiffness to the alloy temperature and the functionality of SMA spring as active variable stiffness actuator (VSA) is analyzed based on factors that are the input conditions (activation current, duty cycle and excitation frequency) and operating conditions (pre-stress and mechanical connection). The model parameters are estimated by adopting the nonlinear least square method, henceforth, the model is validated experimentally. The average correlation factor of 0.95 between the model response and experimental results validates the proposed model. In furtherance, the justification is augmented from the comparison with existing stiffness models (logistic curve model and polynomial model). The important distinction from several observations regarding the comparison of the model prediction with the experimental states that it is more superior, flexible and adaptable than the existing. The nature of stiffness variation in the SMA spring is assessed also from the Dynamic Mechanical Thermal Analysis (DMTA), which as well proves the proposal. This model advances the ability to use SMA integrated mechanism for enhanced variable stiffness actuation. The investigation proves that the stiffness of SMA spring may be altered under controlled conditions.

A New Random SPWM Technique for AC-AC Converter-Based WECS

  • Singh, Navdeep;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.939-950
    • /
    • 2015
  • A single-stage AC-AC converter has been designed for a wind energy conversion system (WECS) that eliminates multistage operation and DC-link filter elements, thus resolving size, weight, and reliability issues. A simple switching strategy is used to control the switches that changes the variable-frequency AC output of an electrical generator to a constant-frequency supply to feed into a distributed electrical load/grid. In addition, a modified random sinusoidal pulse width modulation (RSPWM) technique has been developed for the designed converter to make the overall system more efficient by increasing generating power capacity and reducing the effects of inter-harmonics and sub-harmonics generated in the WECS. The technique uses carrier and reference waves of variable switching frequency to calculate the firing angles of the switches of the converter so that the three-phase output voltage of the converter is very close to a sine wave with reduced THD. A comparison of the performance of the proposed RSPWM technique with the conventional SPWM demonstrated that the power generated by a turbine in the proposed approximately increased by 5% to 10% and THD reduces by 40% both in voltage and current with respect to conventional SPWM.

The Application of Variable Frequency Drive for Forced Draft Fan (보일러 압입통풍기용 인버터 적용기술)

  • Lim, Ick-Hun;Kim, Bong-Suck;Ryu, Ho-Seon;Lee, Joo-Hyun;Whang, Young-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.185-187
    • /
    • 2006
  • 본 논문에서는 평택화력 제2호기 FDF(Forced Draft Fan : 압입송풍기, 이하 FDF) 출구의 공기량제어를 Vane Control 시스템으로 구성되어 있는 것을 구동 유도전동기에 가변속 제어시스템(이하 VFD: Variable Frequency Drive)으로 교체하여 발생한 실험결과를 보여준다. VFD는 Vane을 전개(全開)하고 전동기 속도를 변경시켜 연소에 필요한 노내 공기량을 제어하는 방식이다. VFD 운전은 정속도 Vane 개도 운전에 비해 Throttle Loss를 최소화해서 에너지 절감효과는 크지만 간단한 Vane 제어기에 비해 복잡한 전력전자제어시스템이 어우러진 기기로 신뢰도는 떨어지는 것이 사실이다. 따라서 고도의 신뢰성이 요구되는 전력생산 보일러에서 후비보호책으로 VFD 고장 시에 Vane제어 모드로 절환은 필연적으로 필요한 설비이다. VFD에서 Vane으로 절환 시에 일어나는 과도상태를 최소화하기 위해서는 보일러 연소제어 알고리즘의 최적화가 필요하다. 본 논문에서는 구현된 제어알고리즘을 정리한 것이다.

  • PDF

Sensorless Control for Interior Permanent Magnet Synchronous Motor (IPMSM) using Disturbance Observer with Variable Cut-off Frequency (가변 필터 관측기를 이용한 IPMSM 센서리스 제어)

  • Lee, Jun-Ho;Lee, Hwa-Choon;Lee, Sung-Ho;Jung, Tae-Uk;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2011
  • Using sensors to detect current or voltage of motors is disadvantaged because motor is exposed to vibration, impacts, corrosion, high temperature and humidity in the machinery structure like HEV. In the case of IPMSM, position information is included not only in the flux or EMF term but also in the rotator inductance because of its saliency. To solve this problem, a new mathematical model of IPMSMs on fixed frame is proposed and an extended EMF includiing rotating position information is defined to estimate extended EMF. A strong low-pass filter through the variable cut-off frequency using velocity function was proposed. This makes it is possible to estimate extended EMF by least order disturbance observer. The proposed method was proved through the experiment.

A Novel Variable-Speed Renewable-Energy Generation System of Induction Generator and PWM Converter for Small-Scale Hybrid Power Applications

  • Ahmed, Tarek;Nishida, Katsumi;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1339-1342
    • /
    • 2005
  • This paper presents a simple AC-DC power conditioner for a squirell-cage induction generator(IG) operating under variable shaft speeds. The necessary reactive power for the IG system is supplied by means of a capacitor bank and a voltage-source PWM converter. Using a capacitor bank to transfer the reactive power to the IG under the rated speed and no-load conditions starts the IG operation and reduces the PWM power converter size. A simple control compensating for changes in the electrical loads as well as the variation in speed was developed to regulate the voltages of the IG system by controlling the rotor flux through its reactive and active currents control implementation. This proposed power conditioning scheme can be used efficiently as a wind power generation system where the output voltage of the IG is maintained constant voltage despite the variable frequency and the DC bus voltage of the PWM converter can be used for either DC applications such as battery charging or AC power applications with 60/50 Hz by connecting a stand alone inverter. The experimental and simulated operating performance results of a 5 kW IG scheme at various speeds and leads are presented.

  • PDF

Analysis of Doubly Fed Variable-Speed Pumped Storage Hydropower Plant for Fast Response (빠른 응답성을 갖는 가변속 DFIM 분석)

  • Sun, Jinlei;Seo, Joungjin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.425-430
    • /
    • 2022
  • A pumped storage power station is an important means to solve the problem of peak load regulation and ensures the safety of power grid operation. The doubly fed variable-speed pumped storage (DFVSPS) system adopts a doubly fed induction machine (DFIM) to replace the synchronous machine used in traditional pumped storage. The stator of DFIM is connected to the power grid, and the three-phase excitation windings are symmetrically distributed on the rotor. Excitation current is supplied by the converter. The active and reactive power of the unit can be quickly adjusted by adjusting the amplitude, frequency, and phase of the rotor-side voltage or current through the converter. Compared with a conventional pumped storage hydropower station (C-PSH), DFVSPS power stations have various operating modes and frequent start-up and shutdown. This study introduces the structure and principle of the DFVSPS unit. Mathematical models of the unit, including a model of DFIM, a model of the pump-turbine, and a model of the converter and its control, are established. Fast power control strategies are proposed for the unit model. A 300 MW model of the DFVSPS unit is established in MATLAB/Simulink, and the response characteristics in generating mode are examined.

Variable Backoff Stage(VBS) Algorithm to Reduce Collisions in IEEE 802.11 DCF (IEEE 802.11 DCF 에서의 충돌 감소를 위한 가변 백오프 스테이지(VBS) 알고리즘)

  • Kang, Seongho;Choo, Young-yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1333-1340
    • /
    • 2015
  • IEEE 802.11 MAC(Media Access Control) defines DCF(Distributed Coordination Function) for data transmission control. BEB(Binary Exponential Backoff) algorithm of DCF has a problem that if the number of stations connected are over a certain threshold, it degrades network performance because of packet collisions caused from the minimum contention window size. To cope with this problem, we proposed a novel algorithm, named as VBS(Variable Backoff Stage) algorithm, which adjusts the rate of backoff stage increment depending on the number of stations associated with an AP(Access Point). Analytic model of proposed algorithm was derived and simulations on the BEB and the VBS algorithms have been conducted on the OFDM (Orthogonal Frequency Division Multiplexing) method. Simulation results showed that when the rate of backoff state increment was 5 and 10, the number of retransmission were reduced to 1/5 and 1/10 comparing to that of BEB, respectively. Our algorithm showed improvement of 19% and 18% in network utilization, respectively. Packet delay was reduced into 1/12.

Virtual Inertial Control of a Wind Power Plant using the Maximum Rate of Change of Frequency (주파수의 최대 변화율을 이용한 풍력단지 가상관성제어)

  • Kim, Dooyeon;Kim, Jinho;Lee, Jinshik;Kim, Yeon-Hee;Chun, Yeong-Han;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.918-924
    • /
    • 2013
  • In a conventional power system, the frequency is recovered to the nominal value by the inertial, primary, and secondary responses of the synchronous generators (SGs) after a large disturbance such as a generator tripping. For a power system with high wind penetration, the system inertia is significantly reduced due to the maximum power point tracking control based operation of the variable speed wind generators (WGs). This paper proposes a virtual inertial control for a wind power plant (WPP) based on the maximum rate of change of frequency to release more kinetic energy stored in the WGs. The performance of the proposed algorithm is investigated in a model system, which consists of a doubly fed induction generator-based WPP and SGs using an EMTP-RV simulator. The results indicate that the proposed algorithm can improve the frequency nadir after a generator tripping. In addition, the algorithm can lead the instant of a frequency rebound and help frequency recovery after the frequency rebound.

A Study on the Effect of Perception and Practice of QC Personnel on Post-Management: Focusing on KS Certified Factory Evaluation Criteria (QC담당자의 인식 및 실행이 사후관리에 미치는 영향에 관한 연구: KS인증 공장심사 평가항목을 중심으로)

  • Taek-Yeon Yoo;Jung Eui Hong;Kwang-Soo Kim
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.107-115
    • /
    • 2024
  • This study conducted frequency analysis, reliability analysis, descriptive statistics, and correlation analysis to determine the impact of quality control managers' perception and implementation of KS certification factory inspection evaluation items on follow-up management. Through a multiple linear regression model, the influence of KS certification officer's awareness and implementation of KS certification factory inspection on post management was found to have a positive (+) influence on post management, with implementation having a greater influence on post management than awareness. It was having an impact. The independent variable (perception) has a statistically significant impact on the mediating variable (execution), and in the stage of verifying the mediating effect, the influence of the independent variable (perception) on the dependent variable (follow-up management) has a statistically significant impact. , In the stage where the independent variable (perception) and the mediator (implementation) are input simultaneously, both the independent variable and the mediator have a statistically significant effect on the dependent variable, indicating that there is a mediation effect.