• Title/Summary/Keyword: Variable Thickness

Search Result 651, Processing Time 0.037 seconds

THE STDUY OF THE RELAPSE OF HARD AND SOFT TISSUE AFTER MAXILLARY PROTRACTION (상악골 전방견인 후 경조직과 연조직의 재발에 관한 연구)

  • Yang, Jun-Ho;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.373-389
    • /
    • 1997
  • The purpose of this stdudy was to evaluate the effect of maxillary protraction and the relapse of hard and soft tissue after maxillary protraction. For this study 29 patients who were treated with maxillary protractor and labiolingual archwire were selected. Their mean age was 9 years 4 months and mean treatment period was 8.5 months. Lateral cephalograms were taken at pretreatment, immediately after treatment and one to three months after removal of the maxillary protractor. They were traced on skeletodental and soft tissue structures based on Burstone's analysis and analyzed by Quick-Ceph Image Digitizing System(ORTHODONTIC PROCESSING). The mean and standard deviation between pretreatment and posttreatment and between posttreatment and retention period for each cephalometric variable were calculated. Student t-test was used to determine the statistical significance of the changes in each variable. Correlation coefficients between hard tissue and soft tissue were used to determine interrelationship. The results were as follows. 1. After maxillayy protraction, the maxilla and maxillary dentition moved antero-inferiorly, the mandibld and mandibular dentition moved postero-interiorly and palatal plane rotated antero-superiorly by $0.59^{\circ}$. 2. After maxillary protraction, the soft tissue of upper lip moved antero-interiorly with the movement of hard tissue but the antero-posterior position of lower lip was stable in spite of the change of hard tissue. The thickness of upper lip was decreased and that of lower lip was increased after maxillary Protraction. 3. During the retention period, the position of jaws was relatively stable but upper and lower anterior teeth and antero-superiorly rotated palatal plane relapsed to original position. 4. During the retention period, the soft tissue of lips was stable antero-posteriorly and moved mote inferiorly than posttreatment. 5. The correlation coefficients between the postion of upper and lower incisal edge and that position of lips were high, especially in horizontal change.

  • PDF

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

Morphology, Mineralogy and Genetic Implication of Placer Gold from the Huongkhe Area, Vietnam (베트남 홍케 지역 사금의 산상과 생성연구)

  • Choi, Sang-Hoon;Choi, Seon-Gyu;Han, Jin-Kyun
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.235-246
    • /
    • 1996
  • Placer gold in collected heavy minerals from several localities in Huongkhe area, is consistently very finegrained (${\leq}100$ to $400{\mu}m$). The size and size distribution show somewhat differences at Dongdo and Hoahai : at Dongdo, predominant relatively larger and wide distribution; at Hoahai, characteristic relatively finer and narrow distribution range. The morphology of gold grains is divided into the four groups assumed by the dimension ratio : spherical, subprismoidal, prismoidal, and irregular. The gold grains at Dongdo show wide morphological distribution, whereas, at Hoahai, spherical form is predominant (${\approx}75%$). Three main types of gold are classified based on their chemical composition and mode of occurrence: type I (electrum; fineness=568~931), type II (amalgam; fineness=671~927), and type III (native gold; fineness=923~999). Type I gold contains, relatively high and variable silver contents (${\approx}11$ to 58 atomic % Ag), and has been classified into two subtypes based on their silver contents (type IA, ${\approx}11{\sim}39$ atomic % Ag; type IB, ${\approx}40{\sim}58$ atomic % Ag). However, type I gold would have been generally original compositions of electrum which originated at the provenance deposits. Mercury reacts with gold and silver to form amalgam (type II gold) which has variable Hg contents (1.2~30.5 atomic % Hg). The mercury contents in gold grains at Hoahai (10.9~30.5 atomic % Hg) are higher than those at Dongdo (5.8~21.1 atomic % Hg). The gold grains from the area generally exhibit a high-purity gold (type III) rim. The individual rims on the various grains range from <1 to $80{\mu}m$ in thickness and have silver contents of <10 atomic percent Ag, even though the core compositions range from ${\approx}11$ to 58 atomic percent Ag. The rim of gold most likely is responsible for the commonly cited cases of gold from placer deposits assaying at higher values of fineness than the gold in the corresponding source lode. The gold-rich rim in the Huongkhe area apparently forms by a combination of self-electrorefining and preferential dissolution of silver under oxidizing nature during the weathering and transport process. All data of gold grains in the Huongkhe area suggest that the transport distances and/or time of placer gold at Hoahai are generally farther than those at Dongdo. The mercurian gold bearing provenance deposits at Dongdo and Hoahai would be suggest nearest epithermal gold-silver vein-type.

  • PDF

A Study on the Retrieval of River Turbidity Based on KOMPSAT-3/3A Images (KOMPSAT-3/3A 영상 기반 하천의 탁도 산출 연구)

  • Kim, Dahui;Won, You Jun;Han, Sangmyung;Han, Hyangsun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1285-1300
    • /
    • 2022
  • Turbidity, the measure of the cloudiness of water, is used as an important index for water quality management. The turbidity can vary greatly in small river systems, which affects water quality in national rivers. Therefore, the generation of high-resolution spatial information on turbidity is very important. In this study, a turbidity retrieval model using the Korea Multi-Purpose Satellite-3 and -3A (KOMPSAT-3/3A) images was developed for high-resolution turbidity mapping of Han River system based on eXtreme Gradient Boosting (XGBoost) algorithm. To this end, the top of atmosphere (TOA) spectral reflectance was calculated from a total of 24 KOMPSAT-3/3A images and 150 Landsat-8 images. The Landsat-8 TOA spectral reflectance was cross-calibrated to the KOMPSAT-3/3A bands. The turbidity measured by the National Water Quality Monitoring Network was used as a reference dataset, and as input variables, the TOA spectral reflectance at the locations of in situ turbidity measurement, the spectral indices (the normalized difference vegetation index, normalized difference water index, and normalized difference turbidity index), and the Moderate Resolution Imaging Spectroradiometer (MODIS)-derived atmospheric products(the atmospheric optical thickness, water vapor, and ozone) were used. Furthermore, by analyzing the KOMPSAT-3/3A TOA spectral reflectance of different turbidities, a new spectral index, new normalized difference turbidity index (nNDTI), was proposed, and it was added as an input variable to the turbidity retrieval model. The XGBoost model showed excellent performance for the retrieval of turbidity with a root mean square error (RMSE) of 2.70 NTU and a normalized RMSE (NRMSE) of 14.70% compared to in situ turbidity, in which the nNDTI proposed in this study was used as the most important variable. The developed turbidity retrieval model was applied to the KOMPSAT-3/3A images to map high-resolution river turbidity, and it was possible to analyze the spatiotemporal variations of turbidity. Through this study, we could confirm that the KOMPSAT-3/3A images are very useful for retrieving high-resolution and accurate spatial information on the river turbidity.

Analysis of Empirical Multiple Linear Regression Models for the Production of PM2.5 Concentrations (PM2.5농도 산출을 위한 경험적 다중선형 모델 분석)

  • Choo, Gyo-Hwang;Lee, Kyu-Tae;Jeong, Myeong-Jae
    • Journal of the Korean earth science society
    • /
    • v.38 no.4
    • /
    • pp.283-292
    • /
    • 2017
  • In this study, the empirical models were established to estimate the concentrations of surface-level $PM_{2.5}$ over Seoul, Korea from 1 January 2012 to 31 December 2013. We used six different multiple linear regression models with aerosol optical thickness (AOT), ${\AA}ngstr{\ddot{o}}m$ exponents (AE) data from Moderate Resolution Imaging Spectroradiometer (MODIS) aboard Terra and Aqua satellites, meteorological data, and planetary boundary layer depth (PBLD) data. The results showed that $M_6$ was the best empirical model and AOT, AE, relative humidity (RH), wind speed, wind direction, PBLD, and air temperature data were used as input data. Statistical analysis showed that the result between the observed $PM_{2.5}$ and the estimated $PM_{2.5}$ concentrations using $M_6$ model were correlations (R=0.62) and root square mean error ($RMSE=10.70{\mu}gm^{-3}$). In addition, our study show that the relation strongly depends on the seasons due to seasonal observation characteristics of AOT, with a relatively better correlation in spring (R=0.66) and autumntime (R=0.75) than summer and wintertime (R was about 0.38 and 0.56). These results were due to cloud contamination of summertime and the influence of snow/ice surface of wintertime, compared with those of other seasons. Therefore, the empirical multiple linear regression model used in this study showed that the AOT data retrieved from the satellite was important a dominant variable and we will need to use additional weather variables to improve the results of $PM_{2.5}$. Also, the result calculated for $PM_{2.5}$ using empirical multi linear regression model will be useful as a method to enable monitoring of atmospheric environment from satellite and ground meteorological data.

A Study on the Handles of Clay Cups by Studio Potters (도자기 컵 손잡이에 관한 연구 - 도예공방 생산 수제 컵 손잡이 중심으로 -)

  • Lee, Chi-Youn
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.293-302
    • /
    • 2006
  • clay cups with handles made in studios in Korea and the United States were selected and analyzed. The shape of cup were fixed to ensure proper comparison between handle size of the cup and position. The variable factors were the thickness of the handle, the number of fingers required to hold the cup, the relationship between the handle's shape and the position of its attachment to the cup, the effect of the handle's setter, the change in shape of the handle's thickness, and the relationship between the cup's weight center and handle. Preference test were designed and tested to the users, and the results were analyzed. The results showed that to make a comfortable handle, it is important to incorporate the shape of the resting hand in the design of the handle. Specifically, the design should be such that the cup can be held comfortably. This is possible if the weight of the cup is spread evenly when several fingers are inside the handle's curve and if such factors as the hand size, the curve of the fingers, and the position that best controls the cup's weight center are carefully considered. At this time, if there is a setter for the thumb, a cup of the same weight can be lifted more lightly. In the design of such a cup, the oval line is drawn by extending the cup's handle toward the direction of the cup's body. If the cup's weight center is located on the oval line, the cup's handle may be said to be effective. In such a case, the nearer the handle is to the cup's body weight center, the less power is needed to lift the cup efficiently. Our test results can be applied as a powerful tools in design and manufacturing cups with handle in terms of artistry and functionality.

  • PDF

A Study on the Adolescent Growth Spurt of Skinfold, Muscle and Bone Variables Aligned on Peak Height Velocity in Boys and Girls (PHV 척도를 기준한 피하지방후, 근과 골 변인의 사춘기 발육분출에 관한 연구)

  • Shin Sang-Keun
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.339-344
    • /
    • 2006
  • The aim of this study was to examine the timing and magnitude of growth spurt in skinfold, body musle and bone related variables aligned on peak height velocity in boys and girls. In the study design, the subjects and the method were used by the cross-sectional investigation. The subjects participated in this study were 7 through 18 years of age belonged to typical primary, junior, senior high school students, and about 250 males and 250 females in each age group. The total subjects were 2,798 males and 2,762 females. All subjects of this study were lived in Pusan metropolitan city, Korea. The growth velocity magnitudes of sum of the four sites sknfold thickness, body musle and bone related variables. Velocity curve chart of physique was the smoothed according to an approximation of splines by the Sigma Plot-2001 graphic program. In this study, age at PHV of girls occurred eariler about 2 years than boys. In sum of four sites skinfold thickness, PV occurred -2 years from PHV in boys, and PV occurred +2 years from PHV in girls, respectively. In humerus breadth, two PV occurred before and after PHV in boys, whereas PV occurred -1 year from PHV in girls, respectively. In femur breadth, PFV and PHV appeared to occure the same time in boys, PV occurred -2 years from PHV in girls, respectively, In arm circumference, PV occurred after PHV in both sexes. In calf circumference, PV occurred +2 years from PHV in boys, PCCV and PHV appeared to occure the same time in girls, respectively. In magnitudes of peak velocity of body height, humerus breadth, femur breadth, arm circumference and calf circumfence, boys obtained higher than girls, on the other hand, girls obtained higher than boys in sum of four sites skinfold variable. we need to longitudinal and scientific investigation by Korean government level in adolescent growth spurt study, because childhood and adolescence achive higher positive physical education effect than the other ages.

Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator (선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정)

  • Park, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.87-99
    • /
    • 1994
  • Purpose : The determination of electron beam output factor was investigated from individual applicator for various energy of ML-15MDX linear accelerator. The output factor of electron beam was extended from square to rectangular field in individual applicator size through with a least-square fit to a polynomial expression. Materials : In this experiments. the measurement of output was obtained from 2${\times}$cm$^2$ to 20${\times}$20cm$^2$ of field size in different applicator size for 4 to 15 MaV electron beam energy. The output factor was defined as the ratio of maximum dose output on the central axis of the field of individual applicator size to that of a given field size. Applicator factors were derived from comparing with the output dose of reference field size 10${\times}$10cm$^2$. The thickness of block was specially designed as 10mm in thickness of Lipowitz metal for field shaping in all electron energy. Two types of output curves are included as output factors versus side of square fields and that of variable side length for X and Y in one-dimensional to compare the expected values to that of experiments. Results : Expected output factors of rectangular which was derived from that of square fields in individual applicator size from 2${\times}$2cm$^2$ to 20${\times}$20cm$^2$ in different electron energy was very closed to that of experimental measurements within 2% uncertainty. However 1D method showed a 3% discrepancy in small rectangular field for low energy electron beam. Conclusion : Emperical non-linear polynomial regressions of square root and 1D method were performed to determin the output factor in various field size and electron energy. The expected output of electron beam of square root method for square field and 1D method for rectangular field were very closed to that of measurement in all selected electron beam energy.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

EFFECT OF VARIOUS MECHANICAL TREATMENTS OF HYDROXYAPATITE-COATED IMPLANT SURFACES (Hydroxyapatite 피막 처리된 임프란트에 대한 여러가지 기계적 표면처리방법이 임프란트 표면조도 및 성상에 미치는 영향)

  • Yang, Kyung-Ran;Jung, Oh-Chul;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.131-143
    • /
    • 1994
  • For maintenance of exposed implant in healthy state, it is necessary to treat the surface of implant fixture and provide the surface adjustable to surrounding tissues. Variable techniques have been introduced such as citric acid and air-abrasive system to treat the failed implant. Although when the rough surface of HA coated implant was exposed to oral environment, the surface treatment method with citric acid or air-abrasive system is effective for removal of bacterial endotoxin, it is unsuccessful to prevent plaque deposition due to difficulty in removal of rough surface of HA coated implant. Thus, in this study the method that removes bacterial endotoxin and makes smooch surface without alteration of surface characteristics was studied. HA coated disc manufactured by IMZ Co. Was treated with high speed diamond bur, low speed diamond bur, stone bur, rubber point, jetpolisher. And then its surface state was examined with profilometer and SEM to evaluate the surface smoothness, and its surface component was analyzed with EDX to evaluate wheter the surface characteristics were altered or not. As a result, following results were obtained. When the surface roughness of each implant disc was measured by profilometer, the group I showed a $R_{max}\;2.11{\mu}m$ and the group II, III, IV, V showed a $R_{max2}\;4.17{\mu}m$, $7.28{\mu}m$, $8.61{\mu}m$ and $39.44{\mu}m$ respectively. That is, surface smoothness was highest in the group I and it has been gradually decreased in the group II, III, IV and V. Under the SEM examination, the group I showed relatively smooth surface and the group II showed slightly rougher surface than the group I due to partially remaining HA particles while most HA particle was removed. The group III and IV showed rough topography due to HA particles that was not grinded, and HA coated surface in group V showed very irregular surface with deep groove and prominence. In cross-sectional view, the group I showed uniform surface, and the group III, IV showed rough surface due to remaining HA particles but the thickness of HA coating was remarkably reduced. The group II has similar pattern in group I, and the group V showed about $40{\mu}m$ thickness although it was not constant. By analysis of surface component with EDX, the group II in which the grinding was effective showed a small quantity of calcium and phosphorous and the group III, IV, in which the grinding was incomplete showed calcium and phosphorus peak. In all experimental group, no other than titanium, aluminum, calcium, phosphorus was observed.

  • PDF