• Title/Summary/Keyword: Variable Flow

Search Result 1,304, Processing Time 0.026 seconds

Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic (퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절)

  • 김세영;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF

ANN-Based VRF (variable refrigerant flow) system control (인공신경망 기반 VRF 시스템 제어)

  • Moon, Jin Woo
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.9-16
    • /
    • 2019
  • This study aimed at developing control algorithms for operating a variable refrigerant flow (VRF) heating and cooling system with optimal system parameter set-points. Two artificial neural network (ANN) models, which were respectively designed to predict the heating energy cost and cooling energy amount for upcoming next control cycle, was developed and embedded into the control algorithms. Performance of the algorithms were tested using the computer simulation programs - EnergyPlus, BCVTB, MATLAB in an incorporative manner. The results revealed that the proposed control algorithms remarkably saved the heating energy cost by as much as 7.93% and cooling energy consumption by as much as 28.44%, compared to a conventional control strategy. These findings support that the ANN-based predictive control algorithms showed potential for cost- and energy-effectiveness of VRF heating and cooling systems.

Direct Numerical Simulation of Turbulent Heat Transfer to Water at Supercritical Pressure Flowing in Vertical Pipes (수직원형관내 초임계압 물의 난류 열전달에 관한 직접수치모사)

  • Lee, Sang-Hoon;Bae, Joong-Hun;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2471-2476
    • /
    • 2008
  • Turbulent flow and heat transfer to water at supercritical pressure flowing in vertical pipes is investigated using direct numerical simulation (DNS). A conservative space-time discretization scheme for variable-density flows at low Mach numbers is adopted in the present study to treat steep variations of fluid properties at supercritical pressure just above the thermodynamic critical point. The fluid properties at these conditions are obtained using PROPATH and used in the form of tables in the simulations. The buoyancy influence induced by strong variation of density across the pseudo-critical temperature proved to play an important role in turbulent flow and heat transfer at supercritical state. Depending on the degree of buoyancy influence, turbulent heat transfer may be enhanced or significantly deteriorated, resulting in local hot spots along the heated surface.

  • PDF

Experimental Study on a Rectangular Variable Intake for Space Planes

  • Kojima, T.;Taguchi, H.;Okai, K.;Futamura, H.;Maru, Y.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.649-656
    • /
    • 2004
  • Hypersonic wind tunnel test of the rectangular variable geometry intake is performed. For realization of a Precooled turbojet engine, development of a hypersonic ramjet engine is planned. To investigate performance of the intake of the hypersonic ramjet engine, wind tunnel test is done with freestream Mach number of 5.1. The total pressure recovery was 18 % with 12.9 % of ramp bleed. Several reasons for low total pressure recovery are shown. Supersonic internal compression is not enough. Then, the throat Mach number is high (M2.61) and total pressure losses at the terminal shock is large. Supersonic flow at the throat and position of the terminal shock is sensitive to a difference of the second ramp's throat height and the third ramp's throat height. Flow separations at the second ramp's trailing edge and the third ramp's leading edge are seen those could result in the trigger of unstart. The seal mechanism between the ramps and the sidewalls is important.

  • PDF

The effect of middle school soccer coach's leadership type on sport flow and team atmosphere (중학교 축구지도자의 리더십 유형과 운동 몰입 및 팀 분위기의 관계)

  • Oh, Tae-Hwan;Lee, Sang-Haeng
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.487-494
    • /
    • 2021
  • This study aims to find out how the leadership type of middle school soccer coach affects sport flow and team atmosphere, and the results are as follows. First, as a result of analyzing the demographic characteristics, it was found that there was a significant difference in the peer relationship characteristics of the team atmosphere by the variable of age, and the mutual leadership by the variable of life period with coach. Second, as a result of examining the influence of middle school soccer coach's leadership type on sport flow, it was found that among leadership types, servant leadership affected all sub-factors of sport flow and transformational leadership affected behavioral flow. Third, as a result of examining the effect of middle school soccer coach's leadership type on team atmosphere, it was found that all leadership types had an effect on the role characteristics, which are the sub-factors of team atmosphere, servant leadership on the peer relationship characteristics, and transactional leadership on the team characteristics.

Control of Hot Spots in Plug Flow Reactors Using Constant-temperature Coolant (등온 냉각액을 활용한 plug flow reactor 내의 과열점 제어를 위한 제어모델 개발)

  • Rhyu, Jinwook;Kim, Yeonsoo;Lee, Jong Min
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.77-84
    • /
    • 2021
  • To control hot spot in a plug flow reactor (PFR) is important for the yield and purity of products and safety. In this paper, coolant temperature is set as a state variable, and radial distributions of heat and mass are considered to model the PFR more realistic than without considering radial distributions. The model consists of three state variables, reactant concentration, reactant temperature, and the coolant temperature. The flow rate of the isothermal coolant is a manipulated variable. This paper shows that the controller considering the radial distributions of heat and mass is more effective than the controller without them. Assuming that u3,0 is 0.7, the suggested control equation was robust when St is bigger than 1.3, and Ac/A is smaller than 2.0. Under this condition, the hot spot temperature changed within the relative error of one percent when the temperature of input altered within the range of five percent.

Determinants of Corporate R&D Investment: An Empirical Study Comparing Korea's IT Industry with Its Non-IT Industry

  • Lee, Myeong-Ho;Hwang, In-Jeong
    • ETRI Journal
    • /
    • v.25 no.4
    • /
    • pp.258-265
    • /
    • 2003
  • In our study, we extracted the market, finance, and government factors determining R&D investment of individual firms in the IT industry in Korea. We collected the financial data of 515 individual firms belonging to IT and non-IT industries between 1980 and 1999 from the Korea Investors Service's database and investigated the empirical relationship between the factors using an ordinary regression model, a fixed effects model, and a random effects model. The main findings of our study are as follows: i) The Herfindahl Index variable representing the degree of market concentration is statistically insignificant in explaining R&D expenditures in the IT manufacturing industry. ii) Assets, which is used as a proxy variable for firm size, have a positive and statistically significant coefficient. These two results suggest that the Schumpeterian Hypothesis may be only partially applied to the IT manufacturing industry in Korea. iii) The dividend variable has a negative value and is statistically significant, indicating that a tendency of high dividends can restrict the internal cash flow for R&D investment. iv) The sales variable representing growth potential shows a positive coefficient. v) The subsidy as a proxy variable for governmental R&D promotion policies is positively correlated with R&D expenditure. This suggests that government policy has played a significant role in promoting R&D activities of IT firms in Korea since 1980. vi) Using a dummy variable, we verified that firms reduced their R&D investments to secure sufficient liquidity under the restructuring pressure during Korea's 1998 and 1999 economic crisis.

  • PDF

Study on Analytic of Opening Angles for Muffler Variable Valve of Automobile (자동차 머플러 내의 가변밸브의 열림 각에 관한 해석적 연구)

  • Park, Chungyeol;Kim, Kwonse;Kim, Jongil;Choi, Dooseuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.190-196
    • /
    • 2014
  • Exhaust system by reinforcement of environment regulation came to the foe study necessity. And Exhaust system has necessary to increase the engine performance and silence. From this cause, Automobile has significantly considered production expense. this study makes process for checking the characteristics about Exhaust variable valve within muffler. Variable valve might reduce the baffle within muffler, It was possible to remove the front muffler. Therefor, To miniaturize a size of muffler might be increased by performance through cost-cutting effect and controling of back pressure. Because the Study on Variable valve installed within muffler, to measure the real data was hardly resulted one of the assignments. From manufactured conduct device, might measure data one of piece which was up-graded of problem. Considering to these point, stressed pressure distribution has analyzed on cross section, floating characteristics about velocity distribution around variable valve using analysis as computational fluid dynamics of Ansys with completed measurement data.

An Experimental Study on Flow Characteristics for Dual-Structured Orifice (이중구조 오리피스 팽창장치의 유동특성에 관한 실험적 연구)

  • 곽경민;김하덕;이중형;배철호;김종엽
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1039-1046
    • /
    • 2002
  • To investigate the characteristics of orifice as an expansion devices, the experimental apparatus was made and experiments are being peformed using R22 and R290. The main idea of this control method of refrigerant flow rate with coupled orifices is to control the ON/OFF state of T and Ball type orifice corresponding to the subdivided region of thermal load. When system requires minimum thermal load, both T and Ball type orifices are closed, but refrigerant can flow through small hole of T type orifice. In regular thermal load, when ball type orifice is closed, T type orifice is opened and mass flow rate increase more than OFF state of T type orifice, due to large diameter. In maximum thermal load, both T and Ball type orifices are open and the much refrigerant can flow. The flow characteristics on T type orifice and parallel-combined orifice are obtained in the subdivided region of thermal load.

A Study on the Strategy to Maintain Optimal Flow-rate and Pressure of the Piping System for Individual Heating (개별 난방방식에서의 배관 내 절정 유량 및 압력유지에 관한 연구)

  • Hong Seok-Jin;Ryu Seong-Ryong;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.11-18
    • /
    • 2006
  • For the more comfortable thermal environment in residential buildings, it was necessary for variable components like as automatic flow limiting valves and/or balancing valves in hydronic system. And, these components had an effect on flow-rate and pressure inside pipe. In this case, the incompatibility between the design for the heating system and the selection of equipment was the causes of several problems in heating pipe network. In this study, we peformed measurements and analyses of flow rate and pressure inside pipe for radiant floor heating in residential buildings through field surveys and experiments in order to find out the actual conditions and problems. On the basis of this, we suggested the approach for the optimal flow-rate and pressure maintaining inside pipe in individual heating system.