입자간의 상호작용으로 인한 입자의 운동 및 증발에 미치는 영향 (Influences on the Droplet Dynamics and Evaporation due to Closely Spaced Droplet Interaction)

  • 이효진
    • 대한기계학회논문집
    • /
    • 제16권9호
    • /
    • pp.1770-1779
    • /
    • 1992
  • The present study investigated dynamically and thermally interacting droplets in a closely spaced tandem array. By measuring the velocity and diameter of the droplet traveling along the isothermal vertical plate drag coefficients and vaporization rates of droplets at certain location were obtained. During the experiment initial droplet spacings were less than 5, and initial droplet diameters were ranged between 280 .mu.m and 700 .mu.m Drag coefficients on closely spaced droplets were placed far below the standard drag coefficient, for which it was caused turbulence induced from aforelocating droplets also narrow spaces among droplets restricted heat transfer to droplets from hot gas flow. In addition evaporated vapor entrapted between droplets was major factor in delaying droplet vaporization. With the experimental results the drag coefficient was correlated with respect to Reynolds number for the droplet as follows : $c_{D}$ =2.4/Red.$^{0.37}$

한방치료로 완전 탈락된 鼻茸환자 치험 1예 (A Reports on completely removed Nasal polyp by the more various Hanbang(韓方)-medicine)

  • 오은영;조수현;지선영
    • 한방안이비인후피부과학회지
    • /
    • 제15권1호
    • /
    • pp.219-225
    • /
    • 2002
  • By the treatment of herb-med, acupunture and Korean(韓方)- medicine, symptoms of nasal polyp has taken a turn for the better, but nasal polyp itself was removed in completely was imppssible. Althogh a surgical operation of western -medicine, the nasal polyp tend to recur. In China, the new treatment that Chinese(漢方)-medicine and western-medicine combined was tried. The trial was effective in decreasing recurrance rate and treatment period. But it's a case of completely removed Nasal polyp through the more vanous Korean(韓方)-medicine, The patient answered in the affinnative of electric acupunture, nasal bloodletting, vaporization, external application against the existing treatment(herb-med, acupunture, moxa). If electric acupunture, nasal bloodletting, vaporization, external application are receiving careful study, they are a help to nasal polyp and opthalmologic, otolaryngologic disease.

  • PDF

로켓 엔진의 연소 성능 예측 및 시험 (Performance Prediction of Rocket Engine Combustion and Estimation of Experimental Results)

  • 박정;김용욱;김영한;정용갑;조남경;오승협
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.718-724
    • /
    • 2000
  • A model for depicting the rocket engine combustion process is presented and several experiments near a design point are provided with a FOOF type of unlike impinging injector for a propellant combination of Jet A-1 fuel and liquid-oxygen. The model is based on the assumption that the vaporization is the rate-controlling combustion process. The effects of initial drop size and initial drop velocity are systematically shown and discussed. It is seen that in the midst of considered parameters the change of initial drop size is more sensitive to the performance. The proposed model describes qualitative trends of combustion process well despite of its simplicity.

LNG-FSRU용 재기화 시스템의 열원 온도 및 기화성능의 변동에 따른 시스템 특성분석 (An analysis on the characteristics of regasification system for LNG-FSRU depending on the changes in performance with vaporization and temperature of the heat source)

  • 이윤호;김유택;강호근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.625-631
    • /
    • 2014
  • 본 연구에서는 최근 LNG를 사용하는 화력발전소가 증가함에 따라 등장한 LNG-FSRU (Floating Storage Regasification Unit)에서 LNG를 육상에 있는 소비자에게 기체 상태로 전달하기 위해 Topside에 설치된 재기화 시스템의 열원온도 및 기화성능의 변동에 따른 시스템의 특성분석에 관한 연구이다. 시스템 특성분석을 위하여 LNG가 재기화 할 때 필요한 열원으로써 해수를 사용하는 기화방식과 에틸렌글리콜을 사용하는 기화방식으로 나누어 $-157.9^{\circ}C$, 10,400kPa의 LNG를 시간당 200ton 기화시키는 시스템을 구성하였고, 이때 공급되는 해수온도에 따라 필요한 해수의 최소유량 값을 구하였다. 그리고 에틸렌글리콜을 사용하는 기화방식에서는 지역 및 계절 등의 요인으로 인해 해수온도가 낮아질 경우를 대비하여 $174.5^{\circ}C$, 775kPa의 보일러 스팀을 추가열원으로 설치된 시스템을 구성하고, 필요한 스팀의 생성량을 기화성능에 따라 비교분석함으로써 해수온도 변화에 따라 요구되는 보일러 스팀의 양과 기화성능의 변화에 따른 해수 및 에틸렌글리콜 그리고 스팀의 양을 구하였다.

Vaporization and Conversion of Ethanolamines used in Metalworking Operations

  • Kim, Shin-Bum;Yoon, Chung-Sik;Park, Dong-Uk
    • Safety and Health at Work
    • /
    • 제1권2호
    • /
    • pp.175-182
    • /
    • 2010
  • Objectives: This study examined how ethanolamines (EAs) with the same functional alcohol group ($HOCH_2CH_2$), such as mono-EA (MEA), di-EA (DEA), and tri-EA (TEA), in water-based metalworking fluids (wbMWFs) are vaporized, condensed, and transformed by heat generated during metalworking. Methods: Two types of experimental apparatus were manufactured to achieve these objectives. Results: Vaporization tests using a water bath showed that the vaporization rate increased markedly from $0.19\;mg/m^2{\cdot}min$ at $23.5^{\circ}C$ to $8.04\;mg/m^2{\cdot}min$ at $60^{\circ}C$. Chamber tests with a heat bulb revealed that "spiked" MEA was fully recovered, while only 13.32% of DEA and no TEA were recovered. Interestingly, non-spiked types of EAs were detected, indicating that heat could convert EAs with more alcohol groups (TEA or DEA) into other EAs with fewer group(s) (DEA or MEA). The EA composition in fresh fluid was 4% DEA, 66% TEA, and 30% MEA, and in used fluids (n = 5) was 12.4% DEA, 68% TEA, and 23% MEA. Conversion from TEA into DEA may therefore contribute to the DEA increment. Airborne TEA was not detected in 13 samples taken from the central coolant system and near a conveyor belt where no machining work was performed. The DEA concentration was $0.45\;mg/m^3$ in the only two samples from those locations. In contrast, airborne MEA was found in all samples (n = 53) regardless of the operation type. Conclusion: MEAs easily evaporated even when MWFs were applied, cleaned, refilled, and when they were in fluid storage tanks without any metalworking being performed. The conversion of TEA to DEA and MEA was found in the machining operations.

UV레이저를 이용한 Cr 박막의 어블레이션 (The UV Laser Ablation of Cr film on Glass Substrate)

  • 윤경구;이성국;김재구;최두선;황경현;정재경;장원석;나석주
    • 한국정밀공학회지
    • /
    • 제17권8호
    • /
    • pp.134-139
    • /
    • 2000
  • In order to understand the removal mechanism and seek the optimal conditions. KrF excimer laser ablation of Cr films on glass substrates is investigated. The surface morphology of the laser-irradiated spot is examined by SEM. The measured single-shot ablation rate is found to be about two times the result of numerical analysis based on a surface vaporization model and heat conduction theory. Surface morphology examination indicates that the Cr film is removed by the sequence of melting-surface vaporization-,melt expulsion by plasma recoil and that the outmost ripple of the diffraction pattern gives a strong effect on the morphology of molten Cr during the melting and vaporization processes. To seek the optimal process parameters for micro patterning morphological investigation is carried out experimentally on samples having different chromium film thicknesses. Optimal processing conditions are determined to enhance the accuracy and quality of thin film removal for micro patterning.

  • PDF

Outcome of 980 nm diode laser vaporization for benign prostatic hyperplasia: A prospective study

  • Mithani, M. Hammad;El Khalid, Salman;Khan, Shariq Anis;Sharif, Imran;Awan, Adnan Siddiq;Mithani, Shoaib;Majeed, Irfan
    • Investigative and Clinical Urology
    • /
    • 제59권6호
    • /
    • pp.392-398
    • /
    • 2018
  • Purpose: To evaluate the initial experience and outcome of photo-selective vaporization of the prostate (PVP) for benign prostatic hyperplasia (BPH) in Pakistan with the use of a 980 nm diode laser. Materials and Methods: A prospective study was performed from November 2016 to December 2017. A total of 100 patients diagnosed with bladder outlet obstruction secondary to BPH who planned for PVP were enrolled in the study. PVP was carried out with a diode laser at 980 nm (Biolitec Diode 180W laser) in a continuous wave with a 600 nm (twister) fiber. Baseline characteristics and perioperative data were compared. Postoperative outcomes were evaluated by International Prostate Symptom Score (IPSS), post void residual (PVR) and maximum urinary flow rate (Qmax) at 3 and 6 months after surgery. Results: The mean age was $65.82{\pm}10.42$, mean prostate size was $67.35{\pm}16.42$, operative time was $55.85{\pm}18.01$ and total energy was $198.68{\pm}49.12kJ$. At 3 months and 6 months, significant improvements were noted (p<0.001) in IPSS $7.04{\pm}1.69$ (-18.92), Qmax $19.22{\pm}4.75mL/s$ (+13.09) and and PVR $18.89{\pm}5.39mL$ (-112.80). Most frequent problems were burning micturition (35%) and terminal dysuria (29%). No significant difference in postoperative hemoglobin was seen in patients who were on anti-platelet drugs. Conclusions: PVP with a diode laser is a safe and effective procedure for the treatment of BPH and is also safe in patients who are on anti-platelet agents.

R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성 (Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.

  • PDF

산화제 충진 및 대기 과정의 추진제 공급배관 내부 현상 (Liquid Oxygen in Feeding Line during Propellant Filling and Holding)

  • 권오성;조남경;정용갑;이중엽
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.34-37
    • /
    • 2007
  • 액체산소를 작동유체로 하여 추진제 공급배관에 대한 충진 및 대기 시험을 수행하였다. 추진제 공급 시스템은 추진제 탱크의 출구에 필터가 장착된 형상이다. 추진제의 충진이 완료된 후 대기 과정동안 액체산소의 증발과 이것이 시스템의 재순환 성능에 미치는 영향을 살펴보았다. 추진제의 충진 속도와 탱크 얼리지의 압력이 배관 내 액체산소의 상태에 영향을 미치는 것을 확인하였다. 필터의 장착 위치로 인해 대기 과정동안 배관 내부에서 geysering 현상은 발생하지 않았다.

  • PDF

다성분 혼합연료를 이용한 디젤 분무 및 연소특성의 광계측 진단 (Laser Diagnostics of Spray and Combustion Characteristics Using Multi-Component Mixed Fuels in a D.I. Diesel Engine)

  • 윤준규;명광재;천전이랑;등본원;차경옥
    • 한국자동차공학회논문집
    • /
    • 제14권5호
    • /
    • pp.172-180
    • /
    • 2006
  • This study was to analyze the effect of mixed fuel composition and mass fraction on the characteristics of evaporating diesel spray and combustion under the various ambient conditions. The characteristics of vaporization distribution and combustion were visualized by laser induced fluorescent method and direct photography. The experiments were conducted in the constant volume vessel and rapid compression expansion machine with optical access. Multi-component fuels mixed i-octane, n-dodecane and n-hexadecane were injected the vessel and rapid compression expansion machine with electronically controlled common rail injector. Experimental results show that fuel vapor formed stratified distribution. And vaporization and diffusion are become actively increasing in mass fraction of low boiling point component. Consequently multi-component fuels were expected to control the evaporating behavior according to their suitable mass fraction.