• 제목/요약/키워드: Vapor drift

검색결과 17건 처리시간 0.024초

Improvement of the subcooled boiling model using a new net vapor generation correlation inferred from artificial neural networks to predict the void fraction profiles in the vertical channel

  • Tae Beom Lee ;Yong Hoon Jeong
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4776-4797
    • /
    • 2022
  • In the one-dimensional thermal-hydraulic (TH) codes, a subcooled boiling model to predict the void fraction profiles in a vertical channel consists of wall heat flux partitioning, the vapor condensation rate, the bubbly-to-slug flow transition criterion, and drift-flux models. Model performance has been investigated in detail, and necessary refinements have been incorporated into the Safety and Performance Analysis Code (SPACE) developed by the Korean nuclear industry for the safety analysis of pressurized water reactors (PWRs). The necessary refinements to models related to pumping factor, net vapor generation (NVG), vapor condensation, and drift-flux velocity were investigated in this study. In particular, a new NVG empirical correlation was also developed using artificial neural network (ANN) techniques. Simulations of a series of subcooled flow boiling experiments at pressures ranging from 1 to 149.9 bar were performed with the refined SPACE code, and reasonable agreement with the experimental data for the void fraction in the vertical channel was obtained. From the root-mean-square (RMS) error analysis for the predicted void fraction in the subcooled boiling region, the results with the refined SPACE code produce the best predictions for the entire pressure range compared to those using the original SPACE and RELAP5 codes.

드리프트 플럭스 모델과 2-유체 모델 사이의 상관 관계 (Interrelationship Between the Drift-flux Model and the Two-fluid Model)

  • No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.233-236
    • /
    • 1993
  • 상 변화가 없고 압력 변화가 없는 일차원 이상 유동에 있어서 드리프트 플럭스 모델자 2-유체 모델 사이의 상관 관계가 연구되었다. 증기 보존식은 드리프트 플럭스를 통하여 운동량 보존식에 의존한다는 사실에 기초하여 관계가 얻어졌다. 2-유체 모델로부터 출발하여 트리프트 플럭스의 파라미터의 함수로 표현된 계면 마찰식을 얻었다. 또한 기공 전달식을 유도함으로써 드리프트 플럭스는 2-유체 모델의 마찰력과 상호 관계가 있음을 보였다.

  • PDF

Oxyfluorfen 처리(處理)에 따른 과수종(果樹種) 및 품종간(品種間)의 약해반응(藥害反應) (Phytotoxic Response of Some Fruit Trees to Oxyfluorfen)

  • 조용수;변재균;구자옥
    • 한국잡초학회지
    • /
    • 제7권3호
    • /
    • pp.337-347
    • /
    • 1987
  • Oxyfluorfen 살포(撒布)에 따른 과수종류(果樹種類) 및 품종간(品種間)의 표류비수(漂流飛數) 및 휘산해(揮散害) plastic house에서 조사(調査)하였고, 또한 사과에 대한 살포시기별(撒布時期別) 약해반응(藥害反應)을 포장(圃場)에서 비교(比較)하였다. 가. 수종(數種) 및 품종별(品種別) 약해반응(藥害反應) (1) 발아율감소(發芽率減少)에 미치는 oxyfluorfen의 해(害)를 보면 표류비산해(漂流飛散害) 및 휘산해(煇散害)가 비슷한 정도(程度)로 영향을 주었고 과수종류별(果樹種類別)로는 배와 복숭아가 사과보다 심하였다. (2) 신초당(新梢當) 엽수감소율(葉數減少率)은 사과와 복숭아가 배보다 컸으며 잎의 피해증상(被害症狀)은 배에서 가장 빨리 그러고 심하게 발현되었고 복숭아에서는 가장 경미하고 완만하였다. 피해요인별(被害要因別)로 보면 사과와 배에서는 표류비산해(漂流飛散害)와 휘산해(煇散害)를, 복숭아는 주로 휘산해(煇散害)를 받는 경향이었다. (3) 신초생장억제정도(新梢生長抑制程度)는 복숭아에 비하여 사과와 배에서 컷고, 배는 억제(抑制)가 급진적(急進的)이었으나 사과는 비교적 완만하게 진행(進行)되었다. 약해요인별(藥害要因別)로는 표류비산해(漂流飛散害)와 휘산해(煇散害)가 비슷한 정도(程度)로 나타났다. 나. 약제처리시기별(藥劑處理時期別) 약해반응(藥害反應) (1) Oxyfluorfen은 사과유목(幼木)의 발아(發芽)를 지연시켰는데 지연정도(程度)는 발아기(發芽期) 이전(以前)의 살포(撒布)가 발아기(發芽期)에서 발아완료기(發芽完了期) 사이에 살포(撒布)한 것보다 적었으나 최종 발아(發芽)된 수(數)는 oxyfluorfen 살포(撒布)에 의한 영향을 받지 않았다. 피해엽수(被害葉數)는 처리시기간(處理時期間)에 차이(差異)가 없었으나 피해정도(被害程度)는 발아전(發芽前) 살포(撒布)가 가벼웠다. (2) 신초당(新梢當) 엽수(葉數)와 묘목당(苗木當) 총신초생장량(總新梢生長量) oxyfluorfen의 어느 시기처리(時期處理)에서나 발아후(發芽後) 약 40일까지는 감소(減少)가 인정되었으나 신초생장(新梢生長)이 왕성한 5월 중순 이후에는 처리간(處理間)의 차이(差異)가 거의 없어졌다.

  • PDF

Development of a drift-flux model based core thermal-hydraulics code for efficient high-fidelity multiphysics calculation

  • Lee, Jaejin;Facchini, Alberto;Joo, Han Gyu
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1487-1503
    • /
    • 2019
  • The methods and performance of a pin-level nuclear reactor core thermal-hydraulics (T/H) code ESCOT employing the drift-flux model are presented. This code aims at providing an accurate yet fast core thermal-hydraulics solution capability to high-fidelity multiphysics core analysis systems targeting massively parallel computing platforms. The four equation drift-flux model is adopted for two-phase calculations, and numerical solutions are obtained by applying the Finite Volume Method (FVM) and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE)-like algorithm in a staggered grid system. Constitutive models involving turbulent mixing, pressure drop, and vapor generation are employed to simulate key phenomena in subchannel-scale analyses. ESCOT is parallelized by a domain decomposition scheme that involves both radial and axial decomposition to enable highly parallelized execution. The ESCOT solutions are validated through the applications to various experiments which include CNEN $4{\times}4$, Weiss et al. two assemblies, PNNL $2{\times}6$, RPI $2{\times}2$ air-water, and PSBT covering single/two-phase and unheated/heated conditions. The parameters of interest for validation include various flow characteristics such as turbulent mixing, spacer grid pressure drop, cross-flow, reverse flow, buoyancy effect, void drift, and bubble generation. For all the validation tests, ESCOT shows good agreements with measured data in the extent comparable to those of other subchannel-scale codes: COBRA-TF, MATRA and/or CUPID. The execution performance is examined with a mini-sized whole core consisting of 89 fuel assemblies and for an OPR1000 core. It turns out that it is about 1.5 times faster than a subchannel code based on the two-fluid three field model and the axial domain decomposition scheme works as well as the radial one yielding a steady-state solution for the OPR1000 core within 30 s with 104 processors.

Explaining the Drift Behavior of Caffeine and Glucosamine After Addition of Ethyl Lactate in the Buffer Gas of an Ion Mobility Spectrometer

  • Fernandez-Maestre, Roberto;Velasco, Andres Reyes;Hill, Herbert H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1023-1028
    • /
    • 2014
  • Protonated caffeine ($CH^+$) and glucosamine ($GH^+$) overlapped in an analysis with ion mobility spectrometryquadrupole mass spectrometry. Ethyl lactate vapor (L) at different concentrations from 0 to 22 mmol $m^{-3}$ was added as a buffer gas modifier to separate these signals. The drift times of $CH^+$ and $GH^+$ increased with L concentration. The drift time increase was associated to clustering equilibria of $CH^+$ and $GH^+$ with one molecule of L and the equilibrium of $GH^+$ was more displaced to the formation of $GLH^+$ than that of $GLH^+$. $GH^+$ clustered more to L than $CH^+$ because $GLH^+$ formed more stable hydrogen bonds (26.30 kcal/mol) than $GLH^+$ (24.66 kcal/mol) and the positive charge in $GH^+$ was more sterically accessible than in $CH^+$. The aim of this work was to use theoretical calculations to guide the selection of a buffer gas modifier for IMS separations of two compounds that overlap in the mobility spectra and predict this separation, simplifying that empirical process.

Roll-to-Roll Barrier Coatings on PET Film by Using a Closed Drift Magnetron Plasma Enhanced Chemical Vapor Deposition

  • Lee, Seunghun;Kim, Jong-Kuk;Kim, Do-Geun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.124-125
    • /
    • 2012
  • Korea institute of materials science (KIMS) use a linear deposition source called as a closed drift linear plasma source (CDLPS) as well as dual magnetron sputtering (DMS) to deposit SiOxCyHz films in $HMDSO/O_2$ plasma. The CDLPS generates linear plasma using closed drifting electrons and can reduce device degradations due to energetic ion bombardments on organic devices such as organic photovoltaic and organic light emission diode by controlling an ion energy. The deposited films are investigated by Fourier transform infrared (FT-IR) spectroscopy, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Optical emission spectroscopy (OES) is used to measure relative radical populations of dissociation and recombination products such as H, CH, and CO in plasma. And SiOx film is applied to a barrier film on organic photovoltaic devices.

  • PDF

상대유량 모델내의 기포분포계수 측정에 관한 연구 (Measurements of Void Concentration Parameters in the Drift-Flux Model)

  • 윤병조;박군철;정창현
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.91-101
    • /
    • 1993
  • 가압경수로형 원자로의 정상 비정상 운전시의 열수력학적 거동을 예측하기 위해서는 원자로내기포계수의 분포를 정확히 계산하는 것이 필수적이다. 이러한 기포계수의 정확한 예측을 위하여 많은 모델들이 제시되었다. 이중 drift-flux모델은 그 계산의 정확성과 간결성에 의하여 널리 사용되고 있다. 이러한 drift-flux 모델을 사용하여 보다 더 정확한 기포계수를 예측하기 위해서는 각 상간의 슬립률과 flow regime 에 따른 기포의 운동의 변화가 정확히 고려되어야 한다. Drift-flux 모델에서는 이러한 두 가지 요소가 drift-flux parameter인 $C_{o}$ 와 (equation omitted), 에서 고려된다. 본 연구에서는 이러한 $C_{o}$ 의 실험적 결정을 위하여 원자로 노심을 모사한 4개의 전열봉이 있는 비등이 발생하는 수직사각 유로를 구성하였으며, 완성된 유로내에서 기포계수의 분포 및 기포속도의 분포를 측정하였다. 국부적 기포계수 및 기포속도 분포의 측정에 사용된 방법은 이중탐침법이며 측정이 이루어진 유로내의 유동 상태는 유속이 비교적 느린 low flow rate condition이며 유로내 압력은 3기압 이하이다. 본 실험에서는 액상의 속도는 측정되지 않았으며, 따라서 $C_{o}$ 의 계산을 위하여 (equation omitted)의 실험 상관관계식을 사용하여 유로내 평균 기포계수의 함수로 나타내었다.

  • PDF

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF

농약 Chlorothalonil 과 Command 의 수용성 및 증기압 (Water Solubilities and Vapor Pressures of Chlorothalonil and Command)

  • 김균;김영배;김용화;노정구
    • 한국환경농학회지
    • /
    • 제6권2호
    • /
    • pp.84-93
    • /
    • 1987
  • Chlorothalonil 과 Command 의 수용성과 증기압을 미국 EPA 와 OECD의 방법에 준하여 측정하였다. 두 화합물의 수용성은 문헌치와 잘 일치하였다. 그러나 chlorothalonil의 증기압은 handbook 에 나타난 수치보다 5,000배 낮았고($25^{\circ}C$에서 $2{\times}10torr$)의 Command 증기압은 100배 이상 낮음($45^{\circ}C$에서 $1{\times}10\;torr$ 이하)을 발견하였다. 따라서 handbook 류의 문헌의 물리화학적 특성치를 이용하여 환경동태를 예측하는 데는 주의를 요한다. 이상의 실험을 통하여 실험상의 난점들을 파악할 수 있었고 미국내에서 Command 가 주위작물에 준 표백현상은 증기확산에 의한 것이라기 보다는 살포시 유실에 의한 현상일 가능성이 높을 것으로 추론하였다. 이러한 접근방법은 새로운 화학물질의 개발단계에서 환경동태의 예측, 기존 화학물질의 오염가능성 예측, 오염저감 대책의 제시에 기초가 될 것으로 사료된다.

  • PDF

A Study of the Change of Hall Effect as a Function of the V/III Ratio in n-GaAs compound Semiconductors

  • Kim, In-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권4호
    • /
    • pp.107-110
    • /
    • 2009
  • In this study, the Hall effect has been studied in n-GaAs samples characterized by V/IIl growth ratios of 25, 50 and 100 and prepared by metal organic chemical vapor deposition. For the Hall effect measurements, the grown samples were cut to a size of 1${\times}$1 cm. The measurements were carried out at room temperature, using Indium contact metal at the four corners of the samples. According to the experimental results, the Schottky effect was not ovservation. Also for the n-GaAs sample of V/Ill 100 ratio the electron drift velocity was very high.