• Title/Summary/Keyword: Valve-point

Search Result 223, Processing Time 0.03 seconds

In Vitro Motion Analysis of Supplementary Valve (생체외 실험을 이용한 보조판막의 운동 연구)

  • 김상현;박영환
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • To develop the supplementary heart valve which could reduce the complications of prosthetic heart valve, in vitro experiments were performed to analyze the movement of the supplement valves from the view point of the flow dynamics and leaflet dynamics. The autologous pericardium was attached to deficient portion of the porcine valve which was dissected completely and partially. The pericardium was treated by buffered glutaraldehyde solution in the preshaped mould to preserve the shape of the leaflet. The function of the valves were evaluated in the mock circulatory system and three sets of experiment were performed. The instantaneous motion of the leaflet was pictured by the 35mm camera and the pressure drop through the valve and cardiac output were measured. The supplementary valve which was replaced completely performed better thatn the valve replaced partially. In vitro experiments showed that the supplementary valve which was replaced completely performed better than the valve replaced partially. In vitro experiments showed that the supplementary valve could undertake the prosthetic heart valve in clinic.

  • PDF

A Dynamic Analysis of Valve Mechanism of High-Speed Engine Using FEM (유한요소법을 이요한 고속엔진 밸브 메카니즘의 동적해석)

  • 임상준;이기수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.513-516
    • /
    • 2000
  • This paper presents the analytical studies on the stress and strain of driven valve system of internal combustion engines. The stress and strain is predict using FEM. The particular interest is the dynamic strain at a specific point of the valve and valve seat. Cam and follower Assuming that one rigid surface. This study forced the effects changing Young's modulus and density of valve and valve seat contact area. It supports that the indirect method using FEM is reliable for prediction the actual displacement, stress and strain in the valve system.

  • PDF

Study on Static Characteristics of Hybrid Spool Valve (하이브리드 스폴밸브의 정특성 연구)

  • Yun, So-Nam;Ham, Young-Bok;Kim, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.121-126
    • /
    • 2001
  • In this study, the 4-way spool valve characteristics are clearly defined and proposed new type of spool valve. This paper presents governing equations of the flow through clearances between sleeve and spool as a model of orifice flow for null characteristic analysis, and programmed analysis software of it. This software is possible to basically analysis that not only which case of open center, closed center or critical center but +,- displacement of spool, lab position, boundary region and spool opening of the valve, and to estimate the pressure variation in the spool and external leak flow variation. We are convinced that the scale of load pressure difference is changed as lab condition of spool valve, and this scale is changed with boundary point on the annular clearance. It is vary useful to designer and user of spool valve with this design data and analysis software.

  • PDF

Variations of swirl center according to evaluation position in steady flow bench of SI engine

  • Lee, Sukjong;Sung, Jaeyong;Ohm, In Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1263-1268
    • /
    • 2014
  • In this study, the variations of swirl center according to evaluating position have been investigated in a steady flow bench of SI engine. For the experiments, two engine heads with different intake valve angles ($11^{\circ}$ and $26^{\circ}$) were tested in the flow bench by varying the evaluating position (1.75~6.0B) and valve lift (2~10 mm). Particle image velocimetry was used to measure the velocity field inside the engine cylinder. The swirl center position is found with a critical point theory and the intensity of turbulence is calculated from PIV velocity data. The results show that the center of swirl is located closer to the center of cylinder and turbulence intensity is lower, when the intake valve angle is the smaller. It is conventional to evaluate the swirl ratio at 1.75B position in the steady flow bench of SI engine. At this position, however, the distance of swirl center from the cylinder center scatters significantly for the variation of valve lift, and the turbulence intensity is much stronger regardless of the valve angle. Thus, to estimate the flow at the end of compression stroke in a real engine from the data in the steady flow experiments, the evaluation position should be moved further downstream more than 4.5B.

Numerical Evaluation of Flow Nature at the Downstream of a Ball Valve Used for Gas Pipelines with Valve Opening Rates (개도율에 따른 가스파이프라인용 볼 밸브 후류유동의 수치평가)

  • KIM, CHUL-KYU;LEE, SANG-MOON;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.370-377
    • /
    • 2018
  • Ball valve has been widely used in the field of high-pressure gas pipeline as an important component because of its low flow resistance and good leakage performance. The present paper focuses on the flow nature at the downstream of the ball valve used for gas pipelines according to valve opening rates. Steady 3-D RANS equations, SC/Tetra, have been introduced to analyze the flow characteristics inside the ball valve. Numerical boundary conditions at the inlet and outlet of the valve system are imposed by mass flow-rate and pressure, respectively. Velocity distributions obtained by numerical simulation are compared with respect to the valve opening rates of 30, 50, and 70%. Cavity distributions, asymmetry flow velocity and the flow stabilization point at each opening rate are also compared. When the valve opening rates are 30 and 50%, the flow stabilization requires the sufficient length of 10D or more due to the influence of the recirculation flow at the downstream of the valve.

A Study of Anti-Condensation on the Surface for Aluminum Butterfly Valves (알루미늄 버터플라이밸브의 표면 결로방지에 관한 연구)

  • Kwak, Kyung-Min;Lee, Joong-Hyoung;Cho, Kyung-Chul;Lee, Eun-Ha
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.73-79
    • /
    • 2021
  • The objective of this study is to prevent or decrease condensation on the surface of aluminum butterfly valves used in high humidity air conditions. We proposed a new valve with an anti-condensation device, a heat resistance medium, instead of a conventional valve. We, then, compared the surface temperature distribution between the proposed and conventional valves using experimental and analytical methods. The size of the evaluated valve is 100A and fluid conditions are 35℃/RH 75% in the air outside the valve and 5℃ in the cooling water inside the valve. The experimental results show that the surface temperature of the proposed valve is 23~42% higher than that of a conventional valve, thereby exhibiting an anti-condensation effect. As a result, we observed the complete prevention of condensation on a gear box mounted to the proposed valve, showing surface temperature distribution above the dew point temperature of air. The analytical results are in agreement with the trends in experimental results.

Economic Dispatch Problem Using Advanced Genetic Algorithms (개선된 유전 알고리즘을 이용한 경제급전 문제해석)

  • Park, Jong-Nam;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1106-1108
    • /
    • 1997
  • This paper presents a new approach on genetic algorithms to economic dispatch problem for valve point discontinuities. Proposed approach in this paper on genetic algorithms improves the performance to solve economic dispatch problem for valve point discontinuities through combination in penalty function with death penalty, generation-apart elitism, atavism and heuristic crossover. Numerical results on an actual utility system consisted of 13 thermal units show that the proposed approach is faster and robuster than classical genetic algorithm.

  • PDF

Development of Tractor Three-point Hitch Control System using Proportional Valve (비례밸브를 이용한 트랙터 3점 히치 제어 시스템 개발)

  • Lee, Sang-Sik;Park, Won-Yeop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.89-95
    • /
    • 2011
  • Tractor implements are mainly utilized for the tillage operation. The proposed hydraulic system control was implemented to experimental apparatus. An implement control system for tractor using proportional valve was fabricated to improve the working efficiency. Hydraulic circuit included the proportional solenoid valve and on/off solenoid valve and so on. This paper shows results of a specification and design of an implement control system for tractor using proportional valve for automation. It was conducted to evaluate response characteristics of the designed implement control system under experimental conditions of various input flow rates. The results of experiments showd that the response characteristics was sufficient to be used as the implement control system.

A Study of Valve-train Life Time Estimate in Engine Durability Test (2) (엔진내구시험을 통한 Valve Train 수명예측에 관한 연구 (2))

  • Kim, Jaejin;Lee, Hwanhui;Myung, Wanghee;Min, Byengdu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.75-80
    • /
    • 2014
  • In previous study, make an attempt to estimate exhaust valve seat and seat-ring wear acceleration factor for engine durability test with measuring and consideration of wear mechanism. But found abnormal initial wear rate in exhaust valve seat-ring. And have to improve exhaust valve seat-ring wear rate for reliability reason, because next GDI/Turbo engine is based on this engine and GDI/Turbo engine have higher combustion pressure and higher thermal load. In this study, Trying to find the cause of abnormal wear factor, improve valve-train durability by change specification & design of parts and verify variant parts for improving durability of valve-train. And then I would like to propose a design guide line of valve-train system in a reliability point of view, besides make a complement of previous study.

Intravascular Hemolysis after Prosthetic Valve Replacement (인공판막 치환수술후의 용혈)

  • Jang, Won-Chae;Lee, Gye-Yeong;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1556-1562
    • /
    • 1992
  • Forty two consecutive patients who had had valve replacement with St. Jude Medical prosthesis were studied on a view point of intravascular hemolysis. Patients were consisted of 14 mitral valve replacement, and 7 aortic valve replacement, and 21 double, mitral and aortic, valve replacement. Serum LDH, indirect bilirubin, GOT, hemoglobin levels and ret-iculocyte count were pursued in postopeative 1st day, 3rd day, 7th day, 14th day and 21th day. Postoperatively, all patients were not detected paravalvular leakage on the ech-ocardiographical study. The patients with double valve replacement revealed higher levels of LDH on postopeative 14th day[P<0 05] than those with single valve replacement. Among the patients with single valve replacement, the patients with aortic valve replacement revealed slightly higher levels of entire postopeative data, but considered insignificant. There was correlation between the severity of hemolysis and the size of replaced aortic valve. In the postoperative LDH levels, the patients with small sized-aortic valve[less than 21mm in diameter] replacement revealed higher levels of postoperative 3rd day, 7th day and 14th day than those with large size[more than 23mm in diameter]. The patients with high level LDH of greater than 800 WU /L on postoperative 7th day were 61.9%[26 of 42]. The high LDH frequency of DVR was 71.4%[15 of 21], MVR 50.0%[7 of 14] and AVR, 57.1%[4 of 7]. The level of LDH declined gradualiy thereafter through postoperative 3 weeks. In conclusion, intravascular hemolysis after prosthetic valve replacement was dependent on position of valve replacement and size of valve. And this study supports the conventional valve selection and usage in our hospital. The patients with subclinical hemolysis after valve replacement should be placed on a close observation.

  • PDF