• 제목/요약/키워드: Valve spring

검색결과 169건 처리시간 0.025초

공기구동 게이트밸브의 운전 성능평가 방법에 관한 연구 (A Evaluation Method of Operational Performance for Air-operated Gate Valve)

  • 김대웅;박성근;강신철;김양석
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The valve performance has been evaluated from the theoretical equation based on design information such as packing thrust, spring preload and friction coefficient(${\mu}$). The accuracy of those data can be lower than that of vendor's initial design data. Especially, the friction coefficient can be degraded with time than the original condition and the valve performance calculated using the previous friction coefficient can not be available. Accordingly, this paper is describing a new performance evaluation method of valve based on diagnostic test data which are acquired from a site valve tested in static and dynamic conditions. Especially, this paper provides a new method using friction coefficient(${\mu}$) which is derived from the diagnostic test data acquired in the valve's design basis condition.

가정용 가스보일러 과압방지밸브의 개발 연구 (Development of Relief Valves for the Domestic Gas-fired Hot Water Boilers)

  • 김영규;권정락;김지윤;서준석
    • 한국가스학회지
    • /
    • 제4권1호
    • /
    • pp.63-68
    • /
    • 2000
  • 가정용 가스보일러의 안전장치인 새로운 과압방지밸브를 개발하였다. 본 과압방지밸브는 방출용량을 고려하여 입출구의 구경과 시트구경을 확대하였고, 스프링과 난방수가 닿지 않는 밀봉구조로 설계하여 기존 과압방지밸브의 문제점인 입구유로의 고착, 막힘이나 스프링의 부식현상을 최소화하였다. 개발된 과압방지밸브는 시험결과 분출개시압력, 분출정지압력, 밀폐성, 내구성의 성능특성이 우수하였고, 보일러 설치후의 작동성도 우수한 것으로 평가되었다. 본 연구결과를 통한 과압방지밸브의 표준화와 적용은 부품호환뿐만 아니라 유지보수가 용이하다는 장점을 제공할 수 있을 것이다.

  • PDF

수소 압축기용 릴리프 밸브 모델링 및 성능해석에 관한 연구 (A Study on the Relief Valve Modeling and Performance Analysis of Hydrogen Compressor)

  • 박상법;김규보;전충환;윤소남;권병수
    • 한국수소및신에너지학회논문집
    • /
    • 제20권3호
    • /
    • pp.179-187
    • /
    • 2009
  • This paper presents a static and dynamic characteristics of the relief valve which is a kind of direct operated pressure control valve for hydrogen compressor. The valve is consisted of a main poppet, a spring, an adjuster and a valve body. The purpose of this study is development of the simulation model for relief valve by using commercial AMESlM$^{(R)}$ tool. Poppet with sharp edge seat type and ball poppet with sharp edge seat type compare for P-Q characteristic. The dynamic simulation results are presented the operating pressure characteristics of relief valve. High pressure power unit of which maximum pressure control range is 100MPa was manufactured, and the pressure control valve was experimented using the above-mentioned power unit. The new model of pressure control valve from this results was suggested. It was confirmed that the suggested valve has a good control performance from experimental setup.

HST 중립밸브의 해석모델 개발 및 설계변수 민감도 분석 (Analysis Model Development and Sensitivity Analysis on Design Parameters of the Neutral Valve for HST)

  • 김동명;장주섭;김수철
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권3호
    • /
    • pp.41-46
    • /
    • 2014
  • The neutral valve for controlling the HST is one of the important valves for the vehicle control. Neutral valve takes a role of blocking or transmitting power to the vehicle. The operating principle of the neutral valve was developed through the analysis model. We also investigated the logical validity by analyzing the results of the analysis model. The analysis model was developed by using SimulationX witch is commercial software. The number of holes in the piston was selected as a variable initial compression of the spring, and the magnitude of the pressure pulsations and the diameter of the orifice for the sensitivity analysis were performed to design sensitivity analysis of the neutral valve.

전기 피드백 직동형 서보 밸브에 관한 역 분석 (Reverse Analysis on a Direct Dive Servo Valve with Electric Feedback)

  • 김성동;안희욱
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권4호
    • /
    • pp.22-28
    • /
    • 2013
  • Mechanical and electrical properties of a DDV(Direct Drive servo Valve) with electric feedback are analysed via reverse analysis technique in this work. The DDV is disassembled and mechanical parameters, such as spool mass, spring stiffness and port size are identified. The servo amplifier, which is built in the valve, is reversely analysed and the control scheme and gains for several control actions are also identified. The electrical feedback for spool displacement improves much better the valve performance, such as hysteresis and dynamic bandwidth frequency, than an ordinary mechanical feedback valve. Integrating control action with very large gain was adopted in the valve amplifier, and it seemed to give high performance.

평균분석을 이용한 설계변수가 포핏 밸브의 유동특성에 미치는 영향 (Influence of Design Variables on Flow Characteristics of Poppet Valve using Analysis of Means)

  • 정자영;최은호;강영진;노유정;임오강
    • 한국전산구조공학회논문집
    • /
    • 제30권3호
    • /
    • pp.239-248
    • /
    • 2017
  • 솔레노이드 밸브는 구조에 따라 스풀 밸브와 포핏 밸브로 구분된다. 구조가 단순하고 오염에 민감한 스풀 밸브에 대하여 연구가 많이 진행되고 있는 반면 오염에 덜 민감하고 장시간 작동에 용이한 포핏 밸브는 구조가 복잡하여 여전히 많은 연구가 필요하다. 포핏 밸브를 설계하기 위해서 고려해야 하는 사항으로 포핏의 직경, 포핏의 각도, 디스크의 지름, 스프링 강성, 스프링 예하중, 유로 구조 등 다양한 설계변수가 있다. 기존 연구에서는 설계변수를 한가지로 선정하여 연구가 진행되었고, 설계변수가 포핏 밸브의 유동특성에 미치는 영향에 대한 연구가 부족하다. 본 논문에서는 3/2Way 솔레노이드 밸브용 포핏 밸브의 설계변수 변화에 따른 유동특성의 변화를 분석하였다. 포핏 밸브의 설계변수 선정은 선행연구된 사례와 초기모델해석결과를 참고하여 진행하였다. 그리고 설계변수에 따른 최대압력, 최소압력, 압력강하의 영향을 평균분석(ANOM)을 사용하여 살펴보았다. 향후 3/2Way 솔레노이드 밸브용 포핏 밸브를 설계할 때 주효과를 파악하여 설계변수 선정에 사용하면 효율적인 설계변수 선정이 가능할 것으로 예상된다.

유압원격제어를 위한 덤프와 감압밸브의 특성에 관한 연구 (A Study on Characteristics of Dump and Reducing Valve for Hydraulic Remote Control System)

  • 오철환;김광;송창섭
    • 한국정밀공학회지
    • /
    • 제5권3호
    • /
    • pp.81-90
    • /
    • 1988
  • In recent, the requirement of remote control of hychaulic system is in- creasing. The actuator unit whose output position is proportional to input electrical signal needs a pressure reducer and a dump valve. The pressure reducer provides a constant regulated pressure and filters contaminants. The dump valve supplies proper pressure to the pressure reducer and unloads when the system is not operated. In this thesis, dump valve and pressure reducer with auxiliary function are studied. The choke in the pressure reducer prevents actuator from supplying higher pressure than necessary pressure at beginning, and the spring constant affects on the dynamic characterisics. In dump valve, it is proved that diameter of servo-slide hold and choke diameter of dump plunger affects on damping response.

  • PDF

The Effects of Design Parameters on the Friction Characteristics in the Valve Train System

  • Kim, Ji-Young;Han, Dong-Chul;Cho, Myung-Rae
    • KSTLE International Journal
    • /
    • 제2권1호
    • /
    • pp.75-79
    • /
    • 2001
  • This paper is a report on the parametric study of the friction characteristics on the direct acting type OHC valve train system. The numerical simulation was performed by using the IV-TAP. Dynamic analysis by using the lumped mass method was previously performed to define the acting load. The friction characteristics were analyzed by using the partial asperity contact model. The effects of operating conditions and major design parameters on the total driving torque were investigated. From the analytical prediction, it is found that valve spring stillness, surface roughness, and base circle radius are the main factors to reduce the frictional loss on the valve train system.

  • PDF

Pressure-relief valve 를 적용한 착륙장치 완충장치 설계 (Design of Landing Gear Shock Absorber Using Pressure-relief Valve)

  • 김태욱;신정우;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.508-511
    • /
    • 2008
  • The most landing gear use oleo-pneumatic shock strut to absorb the impact energy during touchdown. The shock strut is composed of the oil damper and the gas spring, especially the oil damper provides resistance force which is proportional to the square of landing speed. In case of high landing speed, the abnormal peak load can be occurred and transferred to the airframe structure. To prevent this, the pressure-relief valve is used to limit the damping force under the specific level. In this paper, it is presented the design process to find optimal damping and analysis results using pressure-relief valve.

  • PDF