• 제목/요약/키워드: Valve prosthesis

검색결과 156건 처리시간 0.018초

쎈트쥬드 대동맥판막의 장기 임상성적 (Clinical Results of the St. Jude Medical Valve in Aortic Pposition)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제28권3호
    • /
    • pp.258-262
    • /
    • 1995
  • We have experienced 18 abdominal aortic aneurysms between March,1987 and June,1994.Unruptured patients were 11 cases and ruptured were 7.The fifth[33.4% ,sixth[27.7% and seventh[27.7% decades were most common age distributions.Sex ratio was 2.6:1[m:f .The most frequent symptoms were abdominal or back pain and palpable pulsating mass.Sixteen patients underwent resection and graft replacement.One patient refused operation.Atherosclerosis was the underlying pathology in 76%.Two ruptured patients died postoperative[28.5% .The frequency of postoperative complication was higher in the ruptured group.

  • PDF

Early Clinical Experience with Sutureless Aortic Valve Replacement for Severe Aortic Stenosis

  • Kim, Do Jung;Kim, Hyo-Hyun;Lee, Shin-Young;Lee, Sak;Chang, Byung-Chul
    • Journal of Chest Surgery
    • /
    • 제51권1호
    • /
    • pp.1-7
    • /
    • 2018
  • Background: Sutureless aortic valve replacement (SU-AVR) has been developed as an alternative surgical treatment for patients with symptomatic severe aortic stenosis (AS). The aim of this study was to evaluate the clinical outcomes of SU-AVR through an assessment of hemodynamic performance and safety. Methods: From December 2014 to June 2016, a total of 12 consecutive patients with severe AS underwent SU-AVR. The endpoints were overall survival and valve-related complications (paravalvular leakage, valve thrombosis, migration, endocarditis, and permanent pacemaker implantation). The mean follow-up duration was $18.1{\pm}8.6months$. Results: The mean age of the patients was $77.1{\pm}5.8years$ and their mean Society of Thoracic Surgeons score was $9.2{\pm}17.7$. The mean cardiopulmonary bypass and aortic cross-clamp times were $94.5{\pm}37.3$ minutes and $54.9{\pm}12.5minutes$, respectively. Follow-up echocardiography showed good prosthesis function with low transvalvular pressure gradients (mean, $13.9{\pm}8.6mm\;Hg$ and peak, $27.2{\pm}15.0mm\;Hg$) at a mean of $9.9{\pm}4.2months$. No cases of primary paravalvular leakage, valve thrombosis, migration, or endocarditis were reported. A new permanent pacemaker was implanted in 1 patient (8.3%). The 1-year overall survival rate was $83.3%{\pm}10.8%$. Conclusion: Our initial experience with SU-AVR demonstrated excellent early clinical outcomes with good hemodynamic results. However, there was a high incidence of permanent pacemaker implantation compared to the rate for conventional AVR, which is a problem that should be solved.

ATS 인공 심장 판막의 단기 및 중기 임상성적 (Short and Intermediate Term Results of the ATS Heart Valve Replacement)

  • 임창영;문승철;양진영;구원모;김대식;이건;이헌재
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

St.Jude Medical 판막의 임상성적 (Clinical Study of St.Jude Medical Cardiac Valve)

  • 김상형;장원채
    • Journal of Chest Surgery
    • /
    • 제27권2호
    • /
    • pp.114-121
    • /
    • 1994
  • St. Jude Medical cardiac valve replacement was performed in 135 consecutive patients from Aug.1986 to Dec. 1991.72 had mitral, 28 had aortic, 1 had tricuspid and 34 had double valve replacement. The hospital mortality rate was 4.4% & the late mortality rate was 3.7 %. Follow-up was done on 115 surviving patients:mean follow-up period was 29.78 $\pm$ 18.32 months. Paravalvular leakage was observed in two patients, possible prosthetic valvular endocarditis wasobserved in one patient and other specific valve-related complications were none. The overall actuarial survival rate at 6 years were 91.6% in total, 96.4% in aortic, 95.5 % in mitral and 81.9 % in double valve replacement.We concluded, therefore that good clinical results and a low complication rate could be achieved with St. Jude Medical valve in short-term follow-up & long-term follow-up was also necessary.

  • PDF

거대상행핵대동맥루를 동반한 대동맥륜확장증 수술 치험: Cabrol씨 수술 1례 보 (Surgical correction in annuloaortic ectasia associated with ascending aortic aneurysm: one case report)

  • 곽문섭
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.753-761
    • /
    • 1984
  • Most patients having annuloaortic ectasia are associated with marked dilatation of the sinuses of Valsalva and the aortic annulus as well as the huge aneurysm of the ascending aorta. A 19 year old male patient complaining of tightness on left posterior chest wall underwent cardiac angiography in which demonstrated annuloaortic ectasia with ascending aortic aneurysm and aortic insufficiency. The patient had corrective operation replacing the ascending aorta and aortic valve with a composite graft[Dacron prosthesis containing a Bjork-Shiley aortic valve] within the aneurysmal sac. The coronary orifices were anastomosed to the tubular Dacron prosthesis [30 mm in diameter] by means of a second smaller Gore-Tex tube [8mm in diameter]. The aneurysmal sac was trimmed by removing the redundant wall and then wrapped outer wall of the Dacron prosthesis. Postoperatively, mediastinal bleeding was temporarily observed in the operative day and satisfactory blood pressure was maintained with small dose of dopamine. One week later, large amount of serous effusion was drained out of the retrosternal space making partial disruption of the skin which was healed well by daily local dressing. The patient discharged in good condition on postoperative 29th day with no residual complications and is doing very well on the 4 months follow-up.

  • PDF

인공심장판막 실패에 대한 재치환술의 임상적 고찰 (Clinical Analysis of Reoperations on Prosthetic Valve Failur)

  • 최병철;유환국;안욱수;허용;김병열;이정호;유회성
    • Journal of Chest Surgery
    • /
    • 제24권7호
    • /
    • pp.663-668
    • /
    • 1991
  • To evaluate risks, complications and mortality of reoperations on heart valve prosthesis, we reviewed clinical records of 53 patients who underwent reoperation because of prosthetic valve failure[PVF], from Jan 1959 through Jun. 1991. They had undergone 48 mitral, 10 aortic valve rereplacement Primary tissue failure was the main cause of reoperation : it occurred in 51 valves at a mean postoperative interval of 58 months. Calcification and collagen disruption of prosthesis were main causes of primary tissue failure in macro and micropathology, In 3 failing mechanical prostheses, paravalvular leak was in 2 cases, another one case had the thrombi at the hinge portion. If conditions such as emergency operation with or without endocarditis, thromboembolism and advanced NYHA functional class are prevented, we think that reoperative valve replacement has similar morbidity and mortality to initial valve replacement surgery. But our sturdy represents higher mortality [22.6%] because of late surgical intervention failing the prevention of conditions leading to myocardial damage. In conclusion if the tearing, calcification, and a new murmur were detected the early reoperation should be considered to increase late survival.

  • PDF

인공판막의 비구조적 기능이상 (Nonstructural Dysfunction of Mechanical Valve)

  • 신종목;정동섭;김경환;안혁
    • Journal of Chest Surgery
    • /
    • 제34권1호
    • /
    • pp.91-93
    • /
    • 2001
  • 기계판막의 비구조적 기능이상은 판막 치환 후 생길 수 있는 심각한 합병증 중의 하나이다. 이러한 기계판막의 비구조적 기능이상은 일반적으로 1) pannus나 조직 혹은 봉합물질에 의한 장애 2) 치환 판막 주위의 틈 3) 부적절한 판막의 크기나 위치, 판막 삽입시의 잘못 등에 의해 생긴다. 저자들은 상대적으로 작은 판막륜을 가진 환자에서 치환 판막의 잘못된 위치로 야기된 pannus 형성에 의한 판막의 기능부전을 경험하였으며, 이 환자에 대해 pannus 제거 후 판막륜 확장술(닉스 술식, Nicks procedure)을 포함한 판막 재치환술을 성공적으로 시행하여 이를 보고하는 바이다.

  • PDF

인공심장판막의 재치환술 (Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases-)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • 제29권2호
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

Medtronic-Hall 기계판막의 임상경험 (Clinical Experience of Medtronic-Hall Valve)

  • 김종원;정성운
    • Journal of Chest Surgery
    • /
    • 제31권11호
    • /
    • pp.1031-1036
    • /
    • 1998
  • 연구배경 : Medtronic-Hall 기계판막은 세계적으로 흔히 쓰이고 있으나, 우리 나라에는 그에 대한 임상연구가 되어 있지 않다 재료 및 방법 : 1986년 3월부터 1990년 5월까지 Medtronic-Hall 기계판막을 이용한 인공 심장판막 치환 환자 50례를 대상으로 하였다. 환자의 평균 연령은 35세였고 남녀비는 17:33이었다. 결과 : 판막 병변의 원인은 류마티스성이 43례로 대부분을 차지했고 38명의 환자에서 승모판 치환술을 7명에서 중복판막치환술을 그리고 5명의 환자에서 대동맥판막 치환술을 시행하였다. 술전 NYHA 기능 분류는 Class III 혹은 Class IV가 91.5%였지만 술후는 ClassI혹은 Class II가 87.2%로 호전된 양상을 보였다. 심장초음파 검사상 좌심방내경, 수축말기 및 확장말기 좌심실내경은 술후 모두 감소하였고 심박출률은 증가하였다. 술후 합병증은 출혈 3례, 저심박출 증후군 2례, 혈전색전증 1례, 전격성 간염 1례가 있었고 병원 사망례는 3례였다. 혈전색전증의 발생률은 1.5%/환자.년이었고 5년 생존률은 93.65$\pm$0.71%, 10년 생존률은 88.27$\pm$6.4%였다. 결론 : 이상에서 Medtronic-Hall 기계판막은 판막에 관련된 합병증 발생률이 낮고 판막의 내구성도 뛰어나며 혈역학적 수행능력이 타 기계판막에 뒤떨어지지 않는 판막으로 확인되었다.

  • PDF

CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구 (Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics.)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF