• Title/Summary/Keyword: Valve prosthesis

Search Result 156, Processing Time 0.025 seconds

A Structural Analysis on the Leaflet Motion Induced by the Blood Flow for Design of a Bileaflet Mechanical Heart Valve Prosthesis

  • Kwon, Young-Joo;Kim, Chang-Nyung;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1316-1323
    • /
    • 2003
  • This paper presents a structural analysis on the rigid and deformed motion of the leaflet induced by the blood flow required in the design of a bileaflet mechanical heart valve (MHV) prosthesis. In the study on the design and the mechanical characteristics of a bileaflet mechanical heart valve, the fluid mechanics analysis on the blood flow passing through leaflets, the kinetodynamics analysis on the rigid body motion of the leaflet induced by the pulsatile blood flow, and the structural mechanics analysis on the deformed motion of the leaflet are required sequentially and simultaneously. Fluid forces computed in the previous hemodynamics analysis on the blood flow are used in the kinetodynamics analysis on the rigid body motion of the leaflet. Thereafter, the structural mechanics analysis on the deformed motion of the leaflet follows to predict the structural strength variation of the leaflet as the leaflet thickness changes. Analysis results show that structural deformations and stresses increase as the fluid pressure increases and the leaflet thickness decreases. Analysis results also show that the leaflet becomes structurally weaker and weaker as the leaflet thickness becomes smaller than 0.6 mm.

Clinical Evaluation of the ATS Valve Replacement (ATS 기계판막의 단기 임상성적)

  • 김학제;조성준
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.293-299
    • /
    • 1997
  • With the introduction of new cardiac prosthesis, it behooves surgeons and cardiologists to monitor its performance carefully. ATS (Advancing The Standard) prosthetic valve has been used first in Guro hospital in Korea, since August 1994. Between August 1994 and July 1995, 21 patients received 28 ATS prosthesis(9 aortic, 19 mitral).19mi1ra1 valves were implanted through the "Extended Transseptal Approach" 10 were ma e and 11 were female, ranging from 20 to 54 years of age(Mean age : 37 years). The follow up period 126 patient-months(mean 6.1 months), varied from 1 month to 12 months. NYHA functional class was improved significantly, from $2.9\pm0.7$ preoperatively to $1.4\pm0.5$ postoperatively. Ejection fraction was also improved from $55.5\pm6.1%$ preoperatively to 59.8 $\pm7.4%$ postoperatively. Lactic dehydrogenase(LDH) was used as an indicator of hemolysis. The value of LDH changed from 483.3 $\pm$ 162 lUlL preoperatively to $527\pm274$ lUff postoperatively with no clinical significailce. Valve related complications, such as thromboembolism, valve thrombosis, anticoagulant related hemorrhage and prosthetic valve endocarditis did not develop except one anticoagulant related intracranial hemorrhage. There were no mortalities. This experience encourages us to continue using the ATS prosthetic valve, and this study will help those patients who need to have their heart valves replaced. replaced.

  • PDF

Short-term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis (St. Jude 기계판막의 단기및 중기 성적)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.57-65
    • /
    • 1992
  • St.Jude Medical cardiac valve replacement was performed in 322 patients: 191 had mitral, 58 had aortic, 72 had double valve and 3 had tricuspid valve replacement. Motality rate in early period was 2.8%[9 patients]. The most common cause of early death was low cardic output syndrome. Follow up extended from 1 to 90 months[mean: 34 months] in 292 patients among 313 in all surviving patients [93.6%]. There were thrombolic complications in eighteen patients. The probability of free from thromboembolism at 5 yerars in MVR, AVR and DVR were 84.7%, 91.8% and 90.2% respectively. And also, actuarial event free rate at 5 years in MVR, AVR and DVR were 80.1%, 82.2%, and 81.4% respectively. There were fourteen late death during follow up period: six from thromboembolism, one from hemorrhage and the others from non valve related -or unknown complications. The acturial survival rate at 5 years were 93.1% in mitral, 92.1% in aortic and 97.1% in double valve replacement. In conclusion, the performance of the St. Jude Mecanical valve compares most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

Long-Term Clinical Results of the St. Jude Medical Valve in Mitral Position (St. Jude 승모판막의 장기 임상성적)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.664-668
    • /
    • 1994
  • A total of 217 patients underwent single mitral valve replacement [MVR] with the St. Jude Medical valve between September 1984 and the end of 1992. There were 86 males and 131 females with a mean age of 34.6 $\pm$ 14.4 years[range 5 months-61 years]. A previous valve replacement had been performed in 46 patients [21.2 %]. An early mortality rate was 7.4 % [5.2 % in primary MVR; and 15.2 %in re-replacement MVR]. Early survivors of 201 patients were followed up for a total of 934.5 patient-years[mean 4.7 $\pm$ 2.1years]. A late mortality rate was 2.5 % or 0.54%/patient-year. The linearized rates of thromboembolism, valve thrombosis and anticoagulation-related bleeding were 1.301 %, 0.214 % and 0.428 %/patient-year, respectively. The actuarial survival including operative mortality was 89.9 % $\pm$ 2.1% at postoperative 10 years. The freedom from thromboemolism was 91.3 %$\pm$ 2.5% and the actuarial estimate of incidence free from late deaths and all complications were 80.9 % $\pm$ 3.8 % at 10 years. There were no mechanical failures. In summary, the St. Jude Medical prosthesis performed satisfactorily with an acceptable rate of late complications.

  • PDF

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.

Interim palatal lift prosthesis as a constituent of multidisciplinary approach in the treatment of velopharyngeal incompetence

  • Raj, Neerja;Raj, Vineet;Aeran, Himanshu
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.243-247
    • /
    • 2012
  • The velopharynx is a tridimensional muscular valve located between the oral and nasal cavities, consisting of the lateral and posterior pharyngeal walls and the soft palate, and controls the passage of air. Velopharyngeal insufficiency may take place when the velopharyngeal valve is unable to perform its own closing, due to a lack of tissue or lack of proper movement. Treatment options include surgical correction, prosthetic rehabilitation, and speech therapy; though optimal results often require a multidisciplinary approach for the restoration of both anatomical and physiological defect. We report a case of 56 year old male patient presenting with hypernasal speech pattern and velopharyngeal insufficiency secondary to cleft palate which had been surgically corrected 18 years ago. The patient was treated with a combination of speech therapy and palatal lift prosthesis employing interim prostheses in various phases before the insertion of definitive appliance. This phase-wise treatment plan helped to improve patient's compliance and final outcome.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Clinical Analysis of St. Jude Medical Prosthesis (St. Jude Medical 기계판막의 임상적 연구)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF